Objectives: The purpose of this study was to analyze the incidence of indications for the removal of mini-plates over a five-year period in maxillofa-cial trauma patients.Materials and Methods: The medical records of 530 patients who underwent treatment with mini-plate fixation after maxillofacial trauma were reviewed for a five-year period (May 2007 to May 2012). Patients were evaluated concerning the number of mini-plates removed, age and gender dis-tributions, time between insertion and removal, indication for removal, and site of removal.Results: The plates of 120 patients were removed (26 females and 94 males). The removal rate was 22.6%. The most frequent indication for removal was patient demand (81.7%), followed by tooth extraction (7.5%), and pain (3.3%). The most frequent removal site was the mandible (95.0%). Conclusion: The number of mini-plates removed was small, and the most common indication for removal was patient demand. There is no evidence to support a recommendation for the routine removal of titanium mini-plates.

Abstract

Objectives: The purpose of this study was to analyze the incidence of indications for the removal of mini-plates over a five-year period in maxillofa-cial trauma patients.Materials and Methods: The medical records of 530 patients who underwent treatment with mini-plate fixation after maxillofacial trauma were reviewed for a five-year period (May 2007 to May 2012). Patients were evaluated concerning the number of mini-plates removed, age and gender dis-tributions, time between insertion and removal, indication for removal, and site of removal.Results: The plates of 120 patients were removed (26 females and 94 males). The removal rate was 22.6%. The most frequent indication for removal was patient demand (81.7%), followed by tooth extraction (7.5%), and pain (3.3%). The most frequent removal site was the mandible (95.0%). Conclusion: The number of mini-plates removed was small, and the most common indication for removal was patient demand. There is no evidence to support a recommendation for the routine removal of titanium mini-plates.

참고문헌 (19)

  1. Haug RH, "Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures", J Oral Maxillofac Surg, 54, pp.611~617 (1996)
  2. Champy M, "Mandibular osteosynthesis by miniature screwed plates via a buccal approach", J Maxillofac Surg, 6, pp.14~21 (1978)
  3. Breme J, "Commercially pure titanium Steinhäuser plate-screw system for maxillofacial surgery", Biomaterials, 9, pp.9~310 (1988)
  4. Alpert B, "Removal of asymptomatic bone plates used for orthognathic surgery and facial fractures", J Oral Maxillofac Surg, 54, pp.618~621 (1996)
  5. Cawood JI, "Small plate osteosynthesis of mandibular fractures", Br J Oral Maxillofac Surg, 23, pp.77~91 (1985)
  6. Michelet FX, "Osteosynthesis with miniaturized screwed plates in maxillo-facial surgery", J Maxillofac Surg, 1, pp.79~84 (1973)
  7. Bhatt V, "Removal of miniplates in maxillofacial surgery: a follow-up study", J Oral Maxillofac Surg, 63, pp.756~760 (2005)
  8. Brown JS, "The fate of miniplates in facial trauma and orthognathic surgery: a retrospective study", Br J Oral Maxillofac Surg, 27, pp.306~315 (1989)
  9. Matthew IR, "Policy of consultant oral and maxillofacial surgeons towards removal of miniplate components after jaw fracture fixation: pilot study", Br J Oral Maxillofac Surg, 37, pp.110~112 (1999)
  10. Islamoglu K, "Complications and removal rates of miniplates and screws used for maxillofacial fractures", Ann Plast Surg, 48, pp.265~268 (2002)
  11. Nagase DY, "Plate removal in traumatic facial fractures: 13-year practice review", Ann Plast Surg, 55, pp.608~611 (2005)
  12. Rallis G, "Reasons for miniplate removal following maxillofacial trauma:a 4-year study", J Craniomaxillofac Surg, 34, pp.435~439 (2006)
  13. ASIF principles, "Internal fixation of the mandibule: a manual of AO", pp.1989, Spiessl B
  14. Rosenberg A, "Should titanium miniplates be removed after bone healing is complete?", Int J Oral Maxillofac Surg, 22, pp.185~188 (1993)
  15. Mosbah MR, "Miniplate removal in trauma and orthognathic surgery--a retrospective study", Int J Oral Maxillofac Surg, 32, pp.148~151 (2003)
  16. Langford RJ, "Surface analysis of titanium maxillofacial plates and screws retrieved from patients", Int J Oral Maxillofac Surg, 31, pp.511~518 (2002)
  17. Winzenburg SM, "Internal fixation in pediatric maxillofacial fractures", Facial Plast Surg, 14, pp.45~58 (1998)
  18. Haug RH, "Plates, screws, and children:their relationship in craniomaxillofacial trauma", J Long Term Eff Med Implants, 13, pp.271~287 (2003)
  19. Chaushu G, "Risk factors contributing to symptomatic plate removal in maxillofacial trauma patients", Plast Reconstr Surg, 105, pp.521~525 (2000)