오른쪽 빗장밑정맥을 이용한 중심정맥도관술에서 환자의 키와 중심정맥카테터의 깊이의 관계

Relationship between Patient Height and Depth of Central Venous Catheter

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Location of the tip of a central venous catheter (CVC) within the pericardium has been associated with potentially lethal cardiac tamponade. The purpose of this study was to show the relationship between the height of patients and the depth of CVC. Methods: We enrolled 262 adult patients into this study. All patients were divided to three groups according to the height; Group S, M and L. Central venous catheterization was performed through the right subclavian vein and the CVC was fixed at the depth of 15 cm from the skin. The distance between the CVC tips and the carina was measured by chest X-ray and was analyzed. Results: The mean (SD) tip position placed via the right subclavian vein was 0.04 (1.6) cm above the carina; Group S, 0.01 (1.8) above the carina, Group M, 0.16 (1.4) above the carina, and Group L, 0.16 (1.8) below the carina. CVC locations could be predicted with a margin of error between 3.1 cm below the carina and 3.2 cm above the carina in 95% of patients. There was no significance difference among the three groups. Conclusions: The relationship between the height of patient and the depth of CVC was low. Because many of the CVC tips were positioned below the carina regardless the height of patients on routine 15 cm-length method, it is recommended not to use the routine 15 cm method with right subclavian CVC placement as far as possible.

Abstract

Background: Location of the tip of a central venous catheter (CVC) within the pericardium has been associated with potentially lethal cardiac tamponade. The purpose of this study was to show the relationship between the height of patients and the depth of CVC. Methods: We enrolled 262 adult patients into this study. All patients were divided to three groups according to the height; Group S, M and L. Central venous catheterization was performed through the right subclavian vein and the CVC was fixed at the depth of 15 cm from the skin. The distance between the CVC tips and the carina was measured by chest X-ray and was analyzed. Results: The mean (SD) tip position placed via the right subclavian vein was 0.04 (1.6) cm above the carina; Group S, 0.01 (1.8) above the carina, Group M, 0.16 (1.4) above the carina, and Group L, 0.16 (1.8) below the carina. CVC locations could be predicted with a margin of error between 3.1 cm below the carina and 3.2 cm above the carina in 95% of patients. There was no significance difference among the three groups. Conclusions: The relationship between the height of patient and the depth of CVC was low. Because many of the CVC tips were positioned below the carina regardless the height of patients on routine 15 cm-length method, it is recommended not to use the routine 15 cm method with right subclavian CVC placement as far as possible.

참고문헌 (30)

  1. 김명화, "Bilateral hydrothorax and cardiac tamponade after right subclavian vein catheterization -A case report-", Korean Journal of Anesthesiology, 59, pp.211~217 (2010), 대한마취과학회
  2. Eerola R, "Analysis of 13800 subclavian vein catheterizations", Acta Anaesthesiol Scand, 29, pp.193~197 (1985)
  3. Muhm M, "Malposition of central venous catheters. Incidence, management and preventive practices", Wien Klin Wochenschr, 109, pp.400~405 (1997)
  4. Sessler CN, "Central venous cannulation done by house officers in the intensive care unit: a prospective study", South Med J, 80, pp.1239~1242 (1987)
  5. Ryu HG, "Bedside prediction of the central venous catheter insertion depth", Br J Anaesth, 98, pp.225~227 (2007)
  6. Collier PE, "Cardiac tamponade from central venous catheters", Am J Surg, 176, pp.212~214 (1998)
  7. Jeon Y, "Transesophageal echocardiographic evaluation of ECG-guided central venous catheter placement", Can J Anaesth, 53, pp.978~983 (2006)
  8. Andropoulos DB, "A controlled study of transesophageal echocardiography to guide central venous catheter placement in congenital heart surgery patients", Anesth Analg, 89, pp.65~70 (1999)
  9. Peres PW, "Positioning central venous catheters--a prospective survey", Anaesth Intensive Care, 18, pp.536~539 (1990)
  10. Czepizak CA, "Evaluation of formulas for optimal positioning of central venous catheters", Chest, 107, pp.1662~1664 (1995)
  11. 이준영, "Depth of a central venous catheter tip: length of insertion guideline for pediatric patients", ACTA ANAESTHESIOL SCAND, 50, pp.355~357
  12. Kang KC, "Determination of the depth of subclavian catheter insertion using chest anteror-posterior film", Korean J Anesthesiol, 37, pp.563~568 (1999)
  13. Chalkiadis GA, "Depth of central venous catheter insertion in adults: an audit and assessment of a technique to improve tip position", Anaesth Intensive Care, 26, pp.61~66 (1998)
  14. Ezri T, "Correct depth of insertion of right internal jugular central venous catheters based on external landmarks: avoiding the right atrium", J Cardiothorac Vasc Anesth, 21, pp.497~501 (2007)
  15. Andrews RT, "How much guidewire is too much? Direct measurement of the distance from sub-clavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement", Crit Care Med, 28, pp.138~142 (2000)
  16. Stuart RK, "Incidence of arrhythmia with central venous catheter insertion and exchange", JPEN J Parenter Enteral Nutr, 14, pp.152~155 (1990)
  17. Johnson D, "Radiological case of the month. Inadvertant guidewire entrapment by IVC filter during subclavian line placement", J Ark Med Soc, 89, pp.517~518 (1993)
  18. Schuster M, "The carina as a landmark in central venous catheter placement", Br J Anaesth, 85, pp.192~194 (2000)
  19. Uchida Y, "Optimal prediction of the central venous catheter insertion depth on a routine chest x-ray", Nutrition, 27, pp.557~560 (2011)
  20. Schroeder RA, "Cardiovascular monitoring. In: Miller's Anesthesia", pp.1285~1297 (2009), Elsevier
  21. Jiha JG, "Intraoperative cardiac tamponade after central venous cannulation", Anesth Analg, 82, pp.664~665 (1996)
  22. Leech RC, "Intraoperative cardiac tamponade after central venous cannulation in an infant during orthotopic liver transplantation", Anesth Analg, 89, pp.342~343 (1999)
  23. Ellis LM, "Central venous catheter vascular erosions. Diagnosis and clinical course", Ann Surg, 209, pp.475~478 (1989)
  24. Ishibashi H, "Delayed hydrothorax induced by a pericutaneous central venous catheter; report of a case", Kyobu Geka, 55, pp.213~215 (2002)
  25. Giacoia GP, "Cardiac tamponade and hydrothorax as complications of central venous parenteral nutrition in infants", JPEN J Parenter Enteral Nutr, 15, pp.110~113 (1991)
  26. Caruso LJ, "A better landmark for positioning a central venous catheter", J Clin Monit Comput, 17, pp.331~334 (2002)
  27. Yoon SZ, "Usefulness of the carina as a radiographic landmark for central venous catheter placement in paediatric patients", Br J Anaesth, 95, pp.514~517 (2005)
  28. Andropoulos DB, "The optimal length of insertion of central venous catheters for pediatric patients", Anesth Analg, 93, pp.883~886 (2001)
  29. Kim MC, "An estimation of right- and left-sided central venous catheter insertion depth using measurement of surface landmarks along the course of central veins", Anesth Analg, 112, pp.1371~1374 (2011)
  30. McGee WT, "Accurate placement of central venous catheters using a 16-cm catheter", J Intensive Care Med, 11, pp.19~22 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (14건)