This report describes a case of systemic thromboembolism caused by left ventricular (LV) thrombosis that developed after placement of an implantable cardioverter-defibrillator (ICD). A 27-year-old male patient was diagnosed with idiopathic dilated cardiomyopathy and ventricular tachycardia, and underwent ICD implantation for the primary prevention of sudden cardiac death. Two weeks after ICD implantation, the patient experienced renal infarction. Transthoracic echocardiography revealed a mobile thrombus at the LV apex, and automated function imaging demonstrated deteriorated LV function after ICD implantation. The RV was not placed by ICD and the mechanical force which was occurred by ICD that led to induced dyssynchronous motion of the LV apex may have resulted in a systemic thromboembolism.
Abstract
This report describes a case of systemic thromboembolism caused by left ventricular (LV) thrombosis that developed after placement of an implantable cardioverter-defibrillator (ICD). A 27-year-old male patient was diagnosed with idiopathic dilated cardiomyopathy and ventricular tachycardia, and underwent ICD implantation for the primary prevention of sudden cardiac death. Two weeks after ICD implantation, the patient experienced renal infarction. Transthoracic echocardiography revealed a mobile thrombus at the LV apex, and automated function imaging demonstrated deteriorated LV function after ICD implantation. The RV was not placed by ICD and the mechanical force which was occurred by ICD that led to induced dyssynchronous motion of the LV apex may have resulted in a systemic thromboembolism.
참고문헌 (11)
- Bailey SM, "Complications of pacemakers and defibrillators in the elderly", Am J Geriatr Cardiol, 15, pp.102~107 (2006)
- Pastore G, "Left ventricular dyssynchrony resulting from right ventricular apical pacing: relevance of baseline assessment", Pacing Clin Electrophysiol, 31, pp.1456~1462 (2008)
- Te CC, "Apparent acute reversible right ventricular pacing-induced left ventricular dysfunction", J Cardiovasc Electrophysiol, 24, pp.224~226 (2013)
- Delewi R, "Left ventricular thrombus formation after acute myocardial infarction", Heart, 98, pp.1743~1749 (2012)
- 신승남, "Left Ventricular Thrombus Associated with Takotsubo Cardiomyopathy: A Cardioembolic Cause of Cerebral Infarction", Journal of Cardiovascular Ultrasound, 19(3), pp.152~155 (2011), 한국심초음파학회
- Grimm W, "Complications of implantable cardioverter defibrillator therapy: follow-up of 241patients", Pacing Clin Electrophysiol, 16, pp.218~222 (1993)
- Rozmus G, "Venous thrombosis and stenosis after implantation of pacemakers and defibrillators", J Interv Card Electrophysiol, 13, pp.9~19 (2005)
- Refaat M, "Right atrial thrombus attached to the defibrillator lead", Nat Clin Pract Cardiovasc Med, 5, pp.354~ (2008)
- Carlson MD, "Lead perforation:incidence in registries", Pacing Clin Electrophysiol, 31, pp.13~15 (2008)
- Belghitia H, "Automated function imaging: a new operator-independent strain method for assessing left ventricular function", Arch Cardiovasc Dis, 101, pp.163~169 (2008)
- Sivri N, "Anticoagulation in Patients With Left Ventricular Systolic Dysfunction and Sinus Rhythm: When?", Clin Appl Thromb Hemost (2013)[DOI]