Surgical management of edentulous/atrophic mandibular fracture: a report of two cases

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

According to Luhr’s classification, a fracture in the mandible with a width of less than 15-20 mm is considered to be an atrophic mandibular fracture and its incidence is very rare. Because of the reduced cross-sectional area and smaller contact area of the fractured ends as well as the poorly vascularized bony structure and delayed bone healing, an atrophic mandibular fracture is a great challenge for oral and maxillofacial surgeons. Surgeons tend to perform closed reduction, because open reduction is considered a non-life-saving surgery among elderly patients. Thus, most of them have limited experience in surgical management. According to recent reports, open reduction yields a good result, and the Association for Osteosynthesis (AO) group has recommended open reduction. This is a case report of our two experiences of open reduction and rigid fixation of atrophic mandibular fractures by the AO principle. Articles were also reviewed here.

Abstract

According to Luhr’s classification, a fracture in the mandible with a width of less than 15-20 mm is considered to be an atrophic mandibular fracture and its incidence is very rare. Because of the reduced cross-sectional area and smaller contact area of the fractured ends as well as the poorly vascularized bony structure and delayed bone healing, an atrophic mandibular fracture is a great challenge for oral and maxillofacial surgeons. Surgeons tend to perform closed reduction, because open reduction is considered a non-life-saving surgery among elderly patients. Thus, most of them have limited experience in surgical management. According to recent reports, open reduction yields a good result, and the Association for Osteosynthesis (AO) group has recommended open reduction. This is a case report of our two experiences of open reduction and rigid fixation of atrophic mandibular fractures by the AO principle. Articles were also reviewed here.

참고문헌 (19)

  1. Luhr HG, "Results of treatment of fractures of the atrophic edentulous mandible by compression plating: a retrospective evaluation of 84 consecutive cases", J Oral Maxillofac Surg, 54, pp.250~254 (1996)
  2. Reich KM, "Atrophy of the residual alveolar ridge following tooth loss in an historical population", Oral Dis, 17, pp.33~44 (2011)
  3. 양순봉, "노인요양시설에 있는 노인환자의 구강실태 및 치료수요도", 대한치과보철학회지, 46(5), pp.455~469 (2008), 대한치과보철학회
  4. Mugino H, "Miniplate osteosynthesis of fractures of the edentulous mandible", Clin Oral Investig, 9, pp.266~270 (2005)
  5. Ellis E 3rd, "Treatment protocol for fractures of the atrophic mandible", J Oral Maxillofac Surg, 66, pp.421~435 (2008)
  6. Zide MF, "Fibula microvascular free tissue reconstruction of the severely comminuted atrophic mandible fracture-- case report", J Craniomaxillofac Surg, 31, pp.296~298 (2003)
  7. ASIF-Maxillofacial Group, "Arbeitsgemeinschaft fü O. Manual of internal fixation in the cranio-facial skeleton: techniques recommended by the AO", pp.1998, Prein J
  8. Madsen MJ, "Management of atrophic mandible fractures", Oral Maxillofac Surg Clin North Am, 21, pp.175~183 (2009)
  9. Pargger H, "Surgical risk and anesthesia in geriatric patients", Orthopade, 23, pp.16~20 (1994)
  10. Bradley JC, "Age changes in the vascular supply of the mandible", Br Dent J, 132, pp.142~144 (1972)
  11. Phillips JH, "Fixation effects on membranous and endochondral onlay bone-graft resorption", Plast Reconstr Surg, 82, pp.872~877 (1988)
  12. Lin KY, "The effect of rigid fixation on the survival of onlay bone grafts: an experimental study", Plast Reconstr Surg, 86, pp.449~456 (1990)
  13. Rüker M, "Reduction of midfacial periosteal perfusion failure by subperiosteal versus supraperiosteal dissection", J Oral Maxillofac Surg, 63, pp.87~92 (2005)
  14. Champy M, "Mandibular osteosynthesis by miniature screwed plates via a buccal approach", J Maxillofac Surg, 6, pp.14~21 (1978)
  15. Sikes JW Jr, "Comparison of fixation strengths of locking head and conventional screws, in fracture and reconstruction models", J Oral Maxillofac Surg, 56, pp.468~473 (1998)
  16. Schmelzeisen R, "Further development of titanium miniplate fixation for mandibular fractures. Experience gained and questions raised from a prospective clinical pilot study with 2.0 mm fixation plates", J Craniomaxillofac Surg, 20, pp.251~256 (1992)
  17. Sikes JW Jr, "An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model", J Oral Maxillofac Surg, 58, pp.56~61 (2000)
  18. Kunz C, "Fractures of the edentulous atrophic mandible. Fracture management and complications", Mund Kiefer Gesichtschir, 5, pp.227~232 (2001)
  19. Haug RH, "Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates", J Oral Maxillofac Surg, 60, pp.1319~1326 (2002)