복강경하 위아전절제술 중 발생한 숨겨진 후복막강 출혈 감지를 위한 경식도 도플러의 유용성
Usability of Esophageal Doppler for Monitoring of Concealed Retroperitoneal Hemorrhage during Laparoscopy Assisted Subtotal Gastrectomy
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Hemodynamic monitoring is an essential element in the management of perioperative patients. In addition, anesthesiologists routinely used blood pressure (invasive or non invasive), heart rate, urinary output and central venous pressure as monitoring modalities. Esophageal doppler monitoring, as a minimally invasive hemodynamic assessment tool, has a good correlation with pulmonary artery catheterization in measuring cardiac output. We experienced a case of concealed retroperitoneal hemorrhage in a patient who underwent a laparoscopic subtotal gastrectomy. When surgeons tried to close trocar sites, the patient's blood pressure dropped rapidly. At laparoscopy, we could not find gross bleeding. However, we could detect hypovolemia by esophageal doppler monitoring (CardioQ, DeltexTM, UK). The procedure was converted to open laparotomy. Thereafter, we could find retroperitoneal hemorrhage, and vascular repair was done successfully. The patient recovered without any other complications.
Abstract
Hemodynamic monitoring is an essential element in the management of perioperative patients. In addition, anesthesiologists routinely used blood pressure (invasive or non invasive), heart rate, urinary output and central venous pressure as monitoring modalities. Esophageal doppler monitoring, as a minimally invasive hemodynamic assessment tool, has a good correlation with pulmonary artery catheterization in measuring cardiac output. We experienced a case of concealed retroperitoneal hemorrhage in a patient who underwent a laparoscopic subtotal gastrectomy. When surgeons tried to close trocar sites, the patient's blood pressure dropped rapidly. At laparoscopy, we could not find gross bleeding. However, we could detect hypovolemia by esophageal doppler monitoring (CardioQ, DeltexTM, UK). The procedure was converted to open laparotomy. Thereafter, we could find retroperitoneal hemorrhage, and vascular repair was done successfully. The patient recovered without any other complications.
참고문헌 (19)
- Kang HG, "Comparison of impedance cardiography with thermodilution of hemodynamic parameters in critically ill patients", Korean J Crit Care Med, 21, pp.77~82 (2006)
- Funk DJ, "Minimally invasive cardiac output monitoring in the perioperative setting", Anesth Analg, 108, pp.887~897 (2009)
- Hashizume M, "Needle and trocar injury during laparoscopic surgery in Japan", Surg Endosc, 11, pp.1198~1201 (1997)
- Hannan EL, "Laparoscopic and open cholecystectomy in New York State: mortality, complications, and choice of procedure", Surgery, 125, pp.223~231 (1999)
- Side CD, "Non-surgical assessment of cardiac function", Nature, 232, pp.335~336 (1971)
- Bae JY, "Is an esophageal doppler monitor useful in hemodynamic monitoring during a laparoscopic cholecystectomy?", Korean J Anesthesiol, 41, pp.275~279 (2001)
- DiCorte CJ, "Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations", Ann Thorac Surg, 69, pp.1782~1786 (2000)
- Madan AK, "Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients", J Trauma, 46, pp.607~611 (1999)
- Singer M, "Esophageal Doppler monitoring of aortic blood flow: beat-by-beat cardiac output monitoring", Int Anesthesiol Clin, 31, pp.99~125 (1993)
- Gardin JM, "Relationship between age, body size, gender, and blood pressure and Doppler flow measurements in the aorta and pulmonary artery", Am Heart J, 113, pp.101~109 (1987)
- King SL, "The use of the oesophageal Doppler monitor in the intensive care unit", Crit Care Resusc, 6, pp.113~122 (2004)
- Marik PE, "Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares", Chest, 134, pp.172~178 (2008)
- Venn R, "Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures", Br J Anaesth, 88, pp.65~71 (2002)
- Valtier B, "Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler", Am J Respir Crit Care Med, 158, pp.77~83 (1998)
- Conway DH, "Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery", Anaesthesia, 57, pp.845~849 (2002)
- Schober P, "Haemodynamic monitoring of critically ill patients with transoesophageal doppler technology", Neth J Crit Care, 14, pp.388~394 (2010)
- Gan TJ, "The oesophageal Doppler monitor", BMJ, 315, pp.893~894 (1997)
- Schober P, "Perioperative hemodynamic monitoring with transesophageal Doppler technology", Anesth Analg, 109, pp.340~353 (2009)
- Lefrant JY, "Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients", Intensive Care Med, 24, pp.347~352 (1998)
