초록

Objectives: This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures. Materials and Methods: A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis. Results: Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure. Conclusion: The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.

Abstract

Objectives: This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures. Materials and Methods: A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis. Results: Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure. Conclusion: The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.

관련 논문AI추천

이 간행물의 다른 논문 (8건)