교합력 측정의 방법과 임상적 적용
The methods for occlusal force measurement and their clinical application
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack-tooth syndrome, temporomandibular disease, and idiopathic implant loosening.
Abstract
The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack-tooth syndrome, temporomandibular disease, and idiopathic implant loosening.
참고문헌 (14)
- Delong R, "Development of an Artificial Oral Environment for the Testing of Dental Restoratives : Bi-axial Force and Movement Control", J Dent Res, 62, pp.32~36 (1983)
- Alemzadeh K, "Prototyping Artificial Jaws for the Bristol Dento-Munch Robo-Simulator 'A parallel robot to test dental components and materials'", Proc Inst Mech Eng H, 222, pp.1209~1220 (2008)
- Ortug G, "A new device for measuring mastication for ce (Gnathodynamometer)", Ann Anat, 184, pp.393~396 (2002)
- Koc D, "Bite force and influential factors on bite force measurements: a literature review", Eur J Dent, 4, pp.223~232 (2010)
- Lassila V, "Bite force and its correlations in different denture types", Acta Odontol Scand, 43, pp.127~132 (1985)
- Ahlgren J, "Muscular activity and chewing force: a polygraphic study of human mandibular movements", Arch Oral Biol, 15, pp.271~280 (1970)
- Gibbs CH, "Occlusal forces during chewing and swallowing as measured by sound transmission", J Prosthet Dent, 46, pp.443~449 (1981)
- Shinogaya T, "Bite force and occlusal load in healthy young subjects--a methodological study", Eur J Prosthodont Restor Dent, 8, pp.11~15 (2000)
- Garg AK, "Analyzing dental occlusion for implants : Tekscan's TScan III", Dent Implantol Update, 18, pp.65~70 (2007)
- Kerstein RB, "Computerized occlusal management of a fixed", detachable implant prosthesis, 1999, pp.11, 1093~1102
- Bachus KN, "Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems", Med Eng Phys, 28, pp.483~488 (2006)
- Sakaguchi Rl, "Douglas WHo Independent movement of cusps during occlusal loading", Dent Mater, 7, pp.186~190 (1991)
- Toparli M, "An investigation of the stress va lues on a tooth restored by amalgam", J Oral Rehabil, 26, pp.259~263 (1999)
- Soares P, "Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars. Part II: strain measurement and stress distribution", J Prosthet Dent, 99, pp.114~122 (2008)
