The diagnosis and establishment of ideal occlusion is most important factor for the patient who needs occlusal treatment or prosthetic rehabilitation. But, Traditionally, Dentists depend on their experiences to evaluate occlusion. With the development of digital dentistry, a computerized system for an objective analysis of dental occlusion has been introduced and is widely used. The T-Scan®III system is a reliable and easy-to-use clinical diagnostic device that recorded and analyzed occlusal contact forces to time using paper-thin sensors. This digital device has application in many phase of dentistry in which occlusal diagnosis and treatment are involved , and remains the only practical quantitative method to analyze the occlusion. In this study, we introduce the T-Scan®III system, capabilities and various clinical applications.

Abstract

The diagnosis and establishment of ideal occlusion is most important factor for the patient who needs occlusal treatment or prosthetic rehabilitation. But, Traditionally, Dentists depend on their experiences to evaluate occlusion. With the development of digital dentistry, a computerized system for an objective analysis of dental occlusion has been introduced and is widely used. The T-Scan®III system is a reliable and easy-to-use clinical diagnostic device that recorded and analyzed occlusal contact forces to time using paper-thin sensors. This digital device has application in many phase of dentistry in which occlusal diagnosis and treatment are involved , and remains the only practical quantitative method to analyze the occlusion. In this study, we introduce the T-Scan®III system, capabilities and various clinical applications.

참고문헌 (23)

  1. Acan M, "Mechanics of contact & memorized birefrin gence", Seances Acad Sci, 290 (1980)
  2. Battistuzzi PG, "Contacts in maximal occlusion", J Oral Rehabil, 9, pp.499~507 (1982)
  3. Beyron H, "Optimal occlusion", Dent Clin North Am, 13, pp.537~554 (1969)
  4. Boening KW, "Computer-aided evaluation of occlusal load in complete dentures", J Prosthet Dent, 67, pp.339~344 (1992)
  5. Chapman RJ, "Principles of occlusion for implant prostheses: guide lines for position, timing, and force of occlusal contacts", Quint essence Int, 20, pp.473~480 (1989)
  6. Dawson PE, "Attaining harmonic occlusion through visualized strain analysis", J Prosthet Dent, 46, pp.615~622 (1981)
  7. Dawson PE, "Evaluation, diagnosis and treatment of occlusal problems", pp.453~456 (1989), Mosby, St. Louis
  8. Gazit E, "Reproducibility of occlusal marking techniques", J Prosthet Dent, 55, pp.505~ (1986)
  9. Gazit E, "The intercuspal surface contact area registration: an additional tool for evaluation of normal occlusion", Angle Orthod, 43, pp.96~106 (1973)
  10. Harvey WL, "Computerized occlusal analysis: an evaluation of the sensors", J Prosthet Dent, 65, pp.89~92 (1991)
  11. Kerstein R, "Disclusion time measurement studies: stability of disclusion time--a 1-year follow-up", J Prosthet Dent, 72, pp.164~168 (1994)
  12. Kerstein RB, "Electromyographic and computer analyses of patients suffering from chronic myofascial paindysfunction syndrome: before and after treatment with immediate complete anterior guidance development", J Prosthet Dent, 66, pp.677~686 (1991)
  13. Kerstein RB, "Disclusion time measurement studies: a comparison of disclusion time between chronic myofascial pain dysfunction patients and nonpatients: a population analysis", J Prosthet Dent, 72, pp.473~480 (1994)
  14. Kerstein RB, "Disocclusion time-reduction therapy with immediate complete anterior guidance development to treat chronic myofascial pain-dysfunction syndrome", Quintessence Int, 23, pp.735~747 (1992)
  15. Kydd WL, "Quantifying contact areas in human dentition", Dent Prog, 2, pp.288~292 (1962)
  16. Maness WL, "Computerized occlusal analysis: a new technology", Quintessence Int, 18, pp.287~292 (1987)
  17. Maness WL, "Distribution of occlusal contacts in maximum intercuspation", J Prosthet Dent, 62, pp.238~242 (1989)
  18. Molligoda MA, "Measuring diurnal variations in occlusal contact areas", J Prosthet Dent, 56, pp.487~492 (1986)
  19. Nabeshima F, "The balance of occlusal contacts during intercuspation using T-scan system", Nihon Hotetsu Shika Gakkai Zasshi, 34, pp.340~349 (1990)
  20. Pahng WD, "The balance of occlusal contacts in normal occlusion during intercu- spal position on T-scan system", J Korean Acad Prosthodont, 29, pp.23~37 (1991)
  21. Riise C, "A clinical study of the number of occlusal tooth contacts in the intercuspal position at light and hard pressure in adults", J Oral Rehabil, 9, pp.469~477 (1982)
  22. Tekscan Inc, "T-ScanⓇ III User Manual" (2009), Boston
  23. Woda A, "Nonfunctional and functional occlusal contacts: a review of the literature", J Prosthet Dent, 42, pp.335~341 (1979)