임플란트와 상부보철물의임상적/실험적 부적합 평가에 관한 문헌고찰
A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.
Abstract
The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.
참고문헌 (47)
- Jemt T, "Measuring fit at the implant prosthodontic interface", J Prosthet Dent, 75, pp.314~325 (1996)[DOI]
- Jimbo R, "Vertical fracture and marginal bone loss of internal-connection implants: a finite element analysis", Int J Oral Maxillofac Implants, 28, pp.e171~e176 (2013)[DOI]
- Cha HS, "Cumulative survival rate and complication rates of single-tooth implant; Focused on the coronal fracture of fixture in the internal connection implant", J Oral Rehabil, 40, pp.595~602 (2013)[DOI]
- Branemark P, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)[DOI]
- Watanabe F, "Analysis of stress distribution in a screw-retained implant prosthesis", Int J Oral Maxillofac Implants, 15, pp.209~218 (2000)
- Jemt T, "Prosthesis misfit and marginal bone loss in edentulous implant patients", Int J Oral Maxillofac Implants, 11, pp.620~625 (1996)
- Kosyfaki P, "Relationship between crowns and the periodontium: a literature update", Quintessence Int, 41, pp.109~126 (2010)
- Katsoulis J, "Misfit of implant prosthese and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature", Eur J Oral Implantol, 10, pp.121~138 (2017)
- Sharkey S, "A Radiographic analysis of implant component misfit", Int J oral Maxillofac Implants, 26, pp.807~815 (2011)
- Hayashi M, "Influence of vision on the evaluation of marginal discrepancies in restorations", Oper Dent, 30, pp.598~601 (2005)
- Hayashi M, "Influence of explorer tip diameter in identifying restoration margin discrepancies", J Dent, 33, pp.669~674 (2005)[DOI]
- Kan JY, "Clinical methods for evaluating implant framework fit", J Prosthet Dent, 81, pp.7~13 (1999)[DOI]
- Jemt T, "Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implant in the edentulous jaw: a study of treatment from the time of prostheses placement to the first annual check up", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
- Jemt T, "Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three dimensional photogrammetric technique", Clin Oral Implants Res, 6, pp.172~180 (1995)[DOI]
- Abduo J, "Assessing the fit of implant fixed prostheses: A critical review", Int J Oral Maxillofac Implants, 25, pp.506~515 (2010)
- Lee JI, "Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study", J Prosthet Dent, 115, pp.161~169 (2016)[DOI]
- Lencioni KA, "Photoelastic comparison of as-cast and laser-welded implant frameworks", J Prosthet Dent, 114, pp.652~659 (2015)[DOI]
- Lee JI, "A photoelastic stress analysis of screw- and cementretained implant prostheses with marginal gaps", Clin Implant Dent Relat Res, 15, pp.735~749 (2013)
- de Torres EM, "Correlation between vertical misfits and stresses transmitted to implants from metal frameworks", J Biomech, 44, pp.1735~1739 (2011)[DOI]
- Termeie D, "Effect of implant diameter and ridge dimension on stress distribution in mandibular first molar siters-A photoelastic study", J Oral Implantol, 41, pp.e165~e173 (2015)[DOI]
- Geng JP, "Application of finite element analysis in implant dentistry: A review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)[DOI]
- Kunavisarut C, "Finite element analysis on dental implant-supported prostheses without passive fit", J Prosthodont, 11, pp.30~40 (2002)
- Assuncao WG, "Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses", Int J Oral Maxillofac Implants, 26, pp.788~796 (2011)
- Dos Santos MB, "Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading", Med Biol Eng Comput, 54, pp.1515~1521 (2016)[DOI]
- Winter W, "Bone adaptation induced by non-passively fitting implant superstructures: A finite element analysis based on in vivo strain measurements", Int J Oral Maxillofac Implants, 26, pp.1288~1295 (2011)
- Brosh T, "The influence of abutment angulation on strains and stresses along the implant", bone interface: Comparison between two experimental techniques, 1998, pp.79, 328~334
- Abduo J, "Influence of vertical misfit of titanium and zirconia frameworks on peri-implant strain", Int J Oral Maxillofac Implants, 27, pp.529~536 (2012)
- De Vasconcellos DK, "Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks", Implant Dent, 21, pp.225~229 (2012)[DOI]
- Tahmaseb A, "Optical scan analysis to detect minor misfit on implant-supported superstructures", Int J Oral Maxillofac Implants, 26, pp.1344~1350 (2011)
- Nascimento Cd, "Marginal fit and microbial leakage along the implant-abutment interface of fixed partial prosthesis: An in vitro analysis using checkerboard DNA-DNA hybridization", J Prosthet Dent, 114, pp.831~838 (2015)[DOI]
- Teixeira W, "Microleakage into and from two-stage implants: An in vitro comparative study", Int J Oral Maxillofac Implants, 26, pp.56~62 (2011)
- Piattelli A, "Fluids and microbial penetration in the internal part of cement-retained versus screwretained implant-abutment connections", J Periodontol, 72, pp.1146~1150 (2001)[DOI]
- do Nascimento C, "Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions", Int J Oral Maxillofac Implants, 27, pp.551~560 (2012)
- Lie A, "Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures", Clin Oral Implants, 5, pp.30~36
- Jemt T, "Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits", Clin Oral Implants Res, 9, pp.272~280 (1998)[DOI]
- Chia VA, "In vitro three-dimensional accuracy of digital implant impressions: The effect of implant angulation", Int J Oral Maxillofac Implants, 32, pp.313~321 (2017)[DOI]
- Geramipanah F, "Effects of impression levels and trays on the accuracy of impressions taken from angulated implants", Clin Oral Implants Res, 26, pp.1098~1105 (2015)[DOI]
- Eliasson A, "The precision of fit of milled titanium implant frameworks in the edentulous jaw", Clin Implant Dent Relat Res, 12, pp.81~90 (2010)
- Alvarez A, "A comparison of two soldering techniques on the misfit of bar-retained implantsupported overdentures", J Prosthodont, 23, pp.163~170 (2014)[DOI]
- Spazzin AO, "Fit analysis of defferent framework fabrication techniques for implant-supported partial prostheses", Int J Prosthodont, 29, pp.351~353 (2016)[DOI]
- Katsoulis J, "CAD", CAM fabrication accuracy of long- vs. shortspan implant-supported FDPs, 2015, pp.26, 245~249
- Katsoulis J, "Precision of fit of implantsupported screw-retained 10-unit computer-aided - designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study", Clin Oral Implants Res, 26, pp.44~49 (2015)
- Pauwels R, "Technical aspects of dental CBCT: state of the art", Dentomaxillofac Radiol, 44, pp.20140224~ (2015)[DOI]
- Rodrigues SA, "The role of welding techniques in the biomechanical behavior of implant-supported prostheses", Mater Sci Eng C Mater Biol Appl, 78, pp.435~442 (2017)[DOI]
- Meleo D, "Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis", Ann Ist Super Sanita, 48, pp.53~58 (2012)
- Blum K, "Fatigue induced changes in conical implant-abutment connections", Dent Mater, 11, pp.1415~1426 (2015)
- Rack A, "In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants", J Synchrotron Radiat, 17, pp.289~294 (2010)[DOI]
