국가차원의 치과 선량관리 (국가진단참고수준: National DRLs)
National-level Dental Radiological Dose Management
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
There is growing public concern about patients' radiation exposure from recent medical imaging using ionizing radiation. While medical radiation exposure has inevitable aspects, efforts to optimize doses in line with the principles of justification and optimization are necessary to maximize diagnostic value with the minimum radiation dose. Diagnostic reference levels have been proposed as a means to achieve optimization, in accordance with ICRP (International Commission on Radiological Protection) publications 60 and 73, as well as EC (European Commission) Directive 97/43/Euratom. According to Requirement 34 of the 'International Basic Safety Standards' published by the IAEA in 2014, governments are recommended to establish national diagnostic reference levels. According to ICRP Publication 135, issued in 2017, national diagnostic reference levels should be revised regularly, preferably every 3-5 years, and more frequently in the case of technological advancements, such as in the case of CBCT. In South Korea, diagnostic reference levels for various imaging modalities have been established since 2007. In the field of dentistry, diagnostic reference levels for intraoral and panoramic radiography were established in 2009, and in 2018, diagnostic reference levels for dental CBCT were introduced for the first time. The purpose of this report is to discuss the current national-level patient radiation dose management in South Korea and explore its applications
Abstract
There is growing public concern about patients' radiation exposure from recent medical imaging using ionizing radiation. While medical radiation exposure has inevitable aspects, efforts to optimize doses in line with the principles of justification and optimization are necessary to maximize diagnostic value with the minimum radiation dose. Diagnostic reference levels have been proposed as a means to achieve optimization, in accordance with ICRP (International Commission on Radiological Protection) publications 60 and 73, as well as EC (European Commission) Directive 97/43/Euratom. According to Requirement 34 of the 'International Basic Safety Standards' published by the IAEA in 2014, governments are recommended to establish national diagnostic reference levels. According to ICRP Publication 135, issued in 2017, national diagnostic reference levels should be revised regularly, preferably every 3-5 years, and more frequently in the case of technological advancements, such as in the case of CBCT. In South Korea, diagnostic reference levels for various imaging modalities have been established since 2007. In the field of dentistry, diagnostic reference levels for intraoral and panoramic radiography were established in 2009, and in 2018, diagnostic reference levels for dental CBCT were introduced for the first time. The purpose of this report is to discuss the current national-level patient radiation dose management in South Korea and explore its applications
참고문헌 (10)
- ICRP, "1990 recommendations of the international commission on radiological protection. International Commission on Radiological Protection; ICRP Publication 60", Ann ICRP, 21(1-3) (1991)
- "European Council Directive 97", 43, 466, pp.Euratom[DOI]
- "European Council Directive 2013", 59, 618, pp.Euratom, 90, 641[DOI]
- "Diagnostic Reference Levels in Medical Imaging" (2017), International Commission on Radiological Protection
- 환자 촬영종류별 진단참고수준 마련: 치과촬영장치(구내, 파노라마, Cone Beam CT), "김은경", ~ (2018)
- Dose to Patients from Dental Radiographic X-ray Imaging Procedures in the UK: 2017 Review, , Public Health England, ~ (2017)
- CRCPD, "Nationwide evaluation of x-ray trends (NEXT): Tabulation and graphical summary of the 2014-2015 dental survey" (2019), CRCPD
- J-RIME, "Japan Network for Research and Information on Medical Exposure, 2020", ~ (2020)
- "Radiation Protection 180, Diagnostic reference levels in thirty-six European countries", European Commission, ~ (2018)
- "Radiation Protection 185, European Guidelines on Diagnostic Reference Levels for Paediatric Imaging", European Commission, ~ (2018)