Development of a Screening Method and Device for the Detection of Escherichia coli from Agri-Food Production Environments and Fresh Produce
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
This study was conducted to develop a screening method using Colilert-18 and a device for the detection of E. coli from agri-food production environments and fresh vegetables. The specificity and sensitivity of Colilert-18 by temperature (37°C and 44°C) were evaluated with 38 E. coli and 78 non-E. coli strains. The false-positive rate was 3.8% (3/78) and 0% (0/78) at 37°C and 44°C, respectively. The detection limit of E. coli at 37°C at <1.0 log CFU/250 ml was lower than that at 44°C. The efficiency of the developed device, which comprised an incubator equipped with a UV lamp to detect E. coli in the field, was evaluated by measuring the temperature and UV lamp brightness. The difference between the set temperature and actual temperature of the developed device was about 1.0°C. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, there were no differences in detection rates of E. coli compared with the Korean Food Code method. For sanitary disposal of culture samples after experiments, the sterilization effect of sodium dichloroisocyanurate (NaDCC) tablets was assessed for use as a substitute for an autoclave. The addition of one tablet of NaDCC per 50 ml was sufficient to kill E. coli cultured in Colilert-18. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.
Abstract
This study was conducted to develop a screening method using Colilert-18 and a device for the detection of E. coli from agri-food production environments and fresh vegetables. The specificity and sensitivity of Colilert-18 by temperature (37°C and 44°C) were evaluated with 38 E. coli and 78 non-E. coli strains. The false-positive rate was 3.8% (3/78) and 0% (0/78) at 37°C and 44°C, respectively. The detection limit of E. coli at 37°C at <1.0 log CFU/250 ml was lower than that at 44°C. The efficiency of the developed device, which comprised an incubator equipped with a UV lamp to detect E. coli in the field, was evaluated by measuring the temperature and UV lamp brightness. The difference between the set temperature and actual temperature of the developed device was about 1.0°C. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, there were no differences in detection rates of E. coli compared with the Korean Food Code method. For sanitary disposal of culture samples after experiments, the sterilization effect of sodium dichloroisocyanurate (NaDCC) tablets was assessed for use as a substitute for an autoclave. The addition of one tablet of NaDCC per 50 ml was sufficient to kill E. coli cultured in Colilert-18. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.
참고문헌 (31)
- CDC, "Preliminary FoodNet data on the incidence of infection with pathogens transmitted commonly through food - 10 states, 2009", MMWR Morb. Mortal. Wkly. Rep, 59, pp.418~ (2010)
- Panel EB., "Scientific opinion on the risk posed by pathogens in food of non-animal origin. Part 1 (outbreak data analysis and risk ranking of food", pathogen combinations), 2013, pp.11, 3025~
- Team EE, "The European Union summary report on trends and sources of zoonoses, zoonotic agents and foodborne outbreaks in 2010", EFSA J, 10, pp.2597~ (2012)
- Olaimat AN, "Factors influencing the microbial safety of fresh produce: a review", Food Microbiol, 32, pp.1~19 (2012)
- Venkateswaran K, "Comparison of commercially available kits with standard methods for the detection of coliforms and Escherichia coli in foods", Appl. Environ. Microbiol, 62, pp.2236~2243 (1996)
- Gunda NSK, "Mobile Water Kit (MWK): a smartphone compatible low-cost water monitoring system for rapid detection of total coliform and E. coli", Anal. Methods, 6, pp.6236~6246 (2014)
- Kim K, "Sensor node for remote monitoring of waterborne disease-causing bacteria", Sensors, 15, pp.10569~10579 (2015)
- Berger S., "Ability of the Colilert method to recover oxidant-stressed Escherichia coli", Lett. Appl. Microbiol, 13, pp.247~250 (1991)
- Covert TC, "Comparing defined-substrate coliform tests for the detection of Escherichia coli in water", J. Am. Water Works Assoc, 84, pp.98~104 (1992)
- Frampton E, "Methods for Escherichia coli identification in food, water and clinical samples based on beta-glucuronidase detection", J. Appl. Bacteriol, 74, pp.223~233 (1993)
- Kawasaki S, "Comparison of traditional culture method with DOX system for detecting coliform and Escherichia coli from vegetables", Food Sci. Technol. Res, 9, pp.304~308 (2003)
- Eccles J, "A comparison of methods used to enumerate Escherichia coli in conventionally treated sewage sludge", J. Appl. Microbiol, 96, pp.375~383 (2004)
- Muirhead R, "Evaluation of the effectiveness of a commercially available defined substrate medium and enumeration system for measuring Escherichia coli numbers in faeces and soil samples", Lett. Appl. Microbiol, 39, pp.383~387 (2004)
- Jain S, "Sodium dichloroisocyanurate tablets for routine treatment of household drinking water in periurban Ghana: a randomized controlled trial", Am. J. Trop. Med. Hyg, 82, pp.16~22 (2010)
- Berger CN, "Fresh fruit and vegetables as vehicles for the transmission of human pathogens", Environ. Microbiol, 12, pp.2385~2397 (2010)
- Abramson A, "Adapting enzymebased microbial water quality analysis to remote areas in low-income countries", Environ. Sci. Technol, 47, pp.10494~10501 (2013)
- Griffin PM, "The epidemiology of infections caused by Escherichia coli O157:H7, other enterohemorrhagic E. coli, and the associated hemolytic uremic syndrome", Epidemiol. Rev, 13, pp.60~98 (1991)
- Maheux AF, "Analytical limits of four β-glucuronidase and β-galactosidase-based commercial culture methods used to detect Escherichia coli and total coliforms", J. Microbiol. Methods, 75, pp.506~514 (2008)
- Wang J, "Emergence of ONPG-negative Shigella sonnei in Shanghai, China", Diagn. Microbiol. Infect. Dis, 83, pp.338~340 (2015)
- McDaniels A, "Confirmational identification of Escherichia coli, a comparison of genotypic and phenotypic assays for glutamate decarboxylase and beta-D-glucuronidase", Appl. Environ. Microbiol, 62, pp.3350~3354 (1996)
- ICMSF, "Microorganisms in Food 5:Microbiological Specifications of Food Pathogens", pp.280~298 (1996), Blackie Academic and Professional
- Small P, "Influence of body temperature on bacterial growth rates in experimental pneumococcal meningitis in rabbits", Infect. Immun, 52, pp.484~487 (1986)
- Palmer CJ, "Evaluation of Colilert-marine water for detection of total coliforms and Escherichia coli in the marine environment", Appl. Environ. Microbiol, 59, pp.786~790 (1993)
- Doyle M, "Survival and growth characteristics of Escherichia coli associated with hemorrhagic colitis", Appl. Environ. Microbiol, 48, pp.855~856 (1984)
- Alonso J, "Quantitative determination of E. coli, and fecal coliforms in water using a chromogenic medium", J. Environ. Sci. Health A Tox. Hazard. Subst. Environ. Eng, 33, pp.1229~1248 (1998)
- Yeom SC., "Sample analysis system using enzyme coloring method", Korea Patent 10-2015-0068755, ~ (2015)
- Lee OJ., "Eschericha coli continuous culture detection system in water sample", Korea Patent 10-2014-1465900, ~ (2014)
- Julian TR, "Genotypic and phenotypic characterization of Escherichia coli isolates from feces, hands, and soils in rural Bangladesh via the Colilert Quanti-Tray system", Appl. Environ. Microbiol, 81, pp.1735~1743 (2015)
- Clasen T, "Sodium dichloroisocyanurate (NaDCC) tablets as an alternative to sodium hypochlorite for the routine treatment of drinking water at the household level", Int. J. Hyg. Environ. Health, 209, pp.173~181 (2006)
- White GC., "Handbook of Chlorination and Alternative Disinfectants" (2010), John Wiley & Sons, Inc
- Schlosser O, "Bacterial removal from inexpensive portable water treatment systems for travelers", J. Travel Med, 8, pp.12~18 (2001)
