Intraoperative neuromonitoring is a well-established method used to prevent intraoperative nerve damage, and manystudies have been performed in thyroid surgery. We introduced the basic concept and practical application ofintraoperative neuromonitoring, as well as its standardized techniques and detailed contents. In addition, the contentsof this still yet relatively unknown field, such as its application in transoral robotic thyroidectomy and its applicationto the external branches of the superior laryngeal nerve, were summarized by referring to many previous studies.
Abstract
Intraoperative neuromonitoring is a well-established method used to prevent intraoperative nerve damage, and manystudies have been performed in thyroid surgery. We introduced the basic concept and practical application ofintraoperative neuromonitoring, as well as its standardized techniques and detailed contents. In addition, the contentsof this still yet relatively unknown field, such as its application in transoral robotic thyroidectomy and its applicationto the external branches of the superior laryngeal nerve, were summarized by referring to many previous studies.
참고문헌 (31)
- Lo CY, "A prospective evaluation of recurrent laryngeal nerve paralysis during thyroidectomy", Arch Surg, 135(2), pp.204~207 (2000)
- Bergenfelz A, "Scandinavian quality register for thyroid and parathyroid surgery : audit of surgery for primary hyperparathyroidism", Langenbecks Arch Surg, 392(4), pp.445~451 (2007)
- Barczynski M, "External branch of the superior laryngeal nerve monitoring during thyroid and parathyroid surgery : International Neural Monitoring Study Group standards guideline statement", Laryngoscope, 123(Suppl 4), pp.S1~S14 (2013)
- Barczynski M, "Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy", Br J Surg, 96(3), pp.240~246 (2009)
- Dionigi G, "Why monitor the recurrent laryngeal nerve in thyroid surgery?", J Endocrinol Invest, 33(11), pp.819~822 (2010)
- Dralle H, "Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery", World J Surg, 32(7), pp.1358~1366 (2008)
- Timmermann W, "Effectiveness and results of intraoperative neuromonitoring in thyroid surgery. Statement of the interdisciplinary study group on intraoperative neuromonitoring of thyroid surgery", Chirurg, 75(9), pp.916~922 (2004)
- Wojtczak B, "Thyroid reoperation using intraoperative neuromonitoring", Endocrine, 58(3), pp.458~466 (2017)
- Sun W, "A meta-analysis of intraoperative neuromonitoring of recurrent laryngeal nerve palsy during thyroid reoperations", Clin Endocrinol(Oxf), 87(5), pp.572~580 (2017)
- Sancho JJ, "Risk factors for transient vocal cord palsy after thyroidectomy", Br J Surg, 95(8), pp.961~967 (2008)
- Lorenz K, "Advantage of intraoperative neuromonitoring of the external branch of the superior laryngeal nerve", Chirurg, 83(10), pp.914~ (2012)
- Aygun N, "Contribution of intraoperative neuromonitoring to the identification of the external branch of superior laryngeal nerve", Turk J Surg, 33(3), pp.169~174 (2017)
- Randolph GW, "Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery : international standards guideline statement", Laryngoscope, 121(Suppl 1), pp.S1~S16 (2011)
- Wu CW, "Intra-operative neural monitoring of thyroid surgery in a porcine model", J Vis Exp, (144) (2019)
- Lamade W, "Intraoperative monitoring of the recurrent laryngeal nerve. A new method", Chirurg, 67(4), pp.451~454 (1996)
- Lamade W, "Transtracheal monitoring of the recurrent laryngeal nerve. Prototype of a new tube", Chirurg, 68(2), pp.193~195 (1997)
- Sun H, "Clinical guidelines on intraoperative neuromonitoring during thyroid and parathyroid surgery", Ann Transl Med, 3(15), pp.213~ (2015)
- Lee HS, "Intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy with adhesive skin electrodes", World J Surg, 44(1), pp.148~154 (2020)
- Wu CW, "Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery", Thyroid, 28(11), pp.1500~1507 (2018)
- Calo PG, "Intraoperative neuromonitoring in thyroid surgery: is the two-staged thyroidectomy justified?", Int J Surg, 41(Suppl 1), pp.S13~S20 (2017)
- Dralle H, "Loss of the nerve monitoring signal during bilateral thyroid surgery", Br J Surg, 99(8), pp.1089~1095 (2012)
- Sadowski SM, "Systematic use of recurrent laryngeal nerve neuromonitoring changes the operative strategy in planned bilateral thyroidectomy", Thyroid, 23(3), pp.329~333 (2013)
- Dionigi G, "Staged thyroidectomy : time to consider intraoperative neuromonitoring as standard of care", Thyroid, 23(7), pp.906~908 (2013)
- Angelos P, "Ethical and medicolegal issues in neuromonitoring during thyroid and parathyroid surgery : a review of the recent literature", Curr Opin Oncol, 24(1), pp.16~21 (2012)
- Dralle H, "Verdicts on malpractice claims after thyroid surgery : emerging trends and future directions", Head Neck, 34(11), pp.1591~1596 (2012)
- Chiang FY, "The mechanism of recurrent laryngeal nerve injury during thyroid surgery--the application of intraoperative neuromonitoring", Surgery, 143(6), pp.743~749 (2008)
- Chai YJ, "Comparative analysis of 2 robotic thyroidectomy procedures : transoral versus bilateral axillo-breast approach", Head Neck, 40(5), pp.886~892 (2018)
- Chae S, "Comparison study of robotic thyroidectomies through a bilateral axillo-breast approach and a transoral approach", J Laparoendosc Adv Surg Tech A, 30(2), pp.175~182 (2020)
- Cernea CR, "Surgical anatomy of the external branch of the superior laryngeal nerve", Head Neck, 14(5), pp.380~383 (1992)
- Hwang SB, "The anatomy of the external branch of the superior laryngeal nerve in Koreans", Asian J Surg, 36(1), pp.13~19 (2013)
- Lee HY, "The efficacy of intraoperative neuromonitoring during robotic thyroidectomy : a prospective, randomized case-control evaluation", J Laparoendosc Adv Surg Tech A, 25(11), pp.908~914 (2015)