After the introduction of intraoperative neural monitoring (IONM) of the recurrent laryngeal nerve (RLN) in clinical thyroid practice almost 16 years ago, the procedure has expanded rapidly with an area-wide spread in Asia, Europe, and USA. While the visual nerve presentation with the eye or the magnifying glass technique is capable of assessing the anatomical continuity of the RLN, IONM additionally allows a functional analysis that has a high correlation, i.e., prediction of postoperative vocal motility. Although the predictive value of the IONM is much higher (>97%) in the case of an intact signal than in the case of a signal failure (40%–70%), the prediction is also unequally higher than the visual-anatomical assessment of the nerve. Thus, IONM can be used as a basis for an intraoperative decision-making of a 1-side or 2-side procedure to avoid bilateral RLN palsy in a bilateral procedure. A precondition for the safe application of IONM is the perfect knowledge of the technology and technique, the routine execution of preoperative and postoperative laryngoscopy, the strict standardization of the neurostimulation (electromyography documentation of the vagal nerve stimulation before and after resection), and an adequate management of technically or operationally caused incidents (i.e., systematic application of troubleshooting algorithms). The following review provides a synopsis of the experiences of the Korean Intraoperative Neural Monitoring Society (KINMoS) for the correct use of IONM.

Abstract

After the introduction of intraoperative neural monitoring (IONM) of the recurrent laryngeal nerve (RLN) in clinical thyroid practice almost 16 years ago, the procedure has expanded rapidly with an area-wide spread in Asia, Europe, and USA. While the visual nerve presentation with the eye or the magnifying glass technique is capable of assessing the anatomical continuity of the RLN, IONM additionally allows a functional analysis that has a high correlation, i.e., prediction of postoperative vocal motility. Although the predictive value of the IONM is much higher (>97%) in the case of an intact signal than in the case of a signal failure (40%–70%), the prediction is also unequally higher than the visual-anatomical assessment of the nerve. Thus, IONM can be used as a basis for an intraoperative decision-making of a 1-side or 2-side procedure to avoid bilateral RLN palsy in a bilateral procedure. A precondition for the safe application of IONM is the perfect knowledge of the technology and technique, the routine execution of preoperative and postoperative laryngoscopy, the strict standardization of the neurostimulation (electromyography documentation of the vagal nerve stimulation before and after resection), and an adequate management of technically or operationally caused incidents (i.e., systematic application of troubleshooting algorithms). The following review provides a synopsis of the experiences of the Korean Intraoperative Neural Monitoring Society (KINMoS) for the correct use of IONM.

참고문헌 (31)

  1. Dralle H, "Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery", Surgery, 136, pp.1310~1322 (2004)[DOI]
  2. Hermann M, "Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk", Ann Surg, 235, pp.261~268 (2002)[DOI]
  3. Cho I, "Some posterior branches of extralaryngeal recurrent laryngeal nerves have motor fibers", Laryngoscope (2017)
  4. Baek SK, "Efficiency of intraoperative neuromonitoring on voice outcomes after thyroid surgery", Auris Nasus Larynx, 44, pp.583~589 (2017)[DOI]
  5. Cha W, "Supramaximal neurostimulation with laryngeal palpation to predict postoperative vocal fold mobility", Laryngoscope, 126, pp.2863~2868 (2016)[DOI]
  6. Wu CW, "Recurrent laryngeal nerve injury with incomplete loss of electromyography signal during monitored thyroidectomy-evaluation and outcome", Langenbecks Arch Surg, 402, pp.691~699 (2017)[DOI]
  7. Lee MS, "Relative direction and position of recurrent laryngeal nerve for anatomical configuration", Surg Radiol Anat, 31, pp.649~655 (2009)[DOI]
  8. Roh JL, "Recurrent laryngeal nerve paralysis in patients with papillary thyroid carcinomas: evaluation and management of resulting vocal dysfunction", Am J Surg, 197, pp.459~465 (2009)[DOI]
  9. Yun JS, "The Zuckerkandl's tubercle: a useful anatomical landmark for detecting both the recurrent laryngeal nerve and the superior parathyroid during thyroid surgery", Endocr J, 55, pp.925~930 (2008)[DOI]
  10. Hong KH, "Phonatory characteristics of patients undergoing thyroidectomy without laryngeal nerve injury", Otolaryngol Head Neck Surg, 117, pp.399~404 (1997)[DOI]
  11. Lamade W, "Effect of training on the incidence of nerve damage in thyroid surgery", Br J Surg, 86, pp.388~391 (1999)[DOI]
  12. Randolph GW, "Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation", World J Surg, 28, pp.755~760 (2004)[DOI]
  13. Sosa JA, "The importance of surgeon experience for clinical and economic outcomes from thyroidectomy", Ann Surg, 228, pp.320~330 (1998)[DOI]
  14. Barczynski M, "Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy", Br J Surg, 96, pp.240~246 (2009)[DOI]
  15. Dralle H, "Intraoperative neuromonitoring of thyroid gland operations: surgical standards and aspects of expert assessment", Chirurg, 81, pp.612~619 (2010)[DOI]
  16. Schneider R, "Continuous intraoperative neural monitoring of the recurrent nerves in thyroid surgery: a quantum leap in technology", Gland Surg, 5, pp.607~616 (2016)[DOI]
  17. Schneider R, "Dynamics of loss and recovery of the nerve monitoring signal during thyroidectomy predict early postoperative vocal fold function", Head Neck, 38(Suppl 1), pp.E1144~E1151 (2016)[DOI]
  18. Phelan E, "Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study", Laryngoscope, 124, pp.1498~1505 (2014)[DOI]
  19. Schneider R, "Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring", World J Surg, 37, pp.364~368 (2013)[DOI]
  20. Schneider R, "Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury", Head Neck, 35, pp.1591~1598 (2013)[DOI]
  21. Schneider R, "Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous or intermittent nerve monitoring", Br J Surg, 102, pp.1380~1387 (2015)[DOI]
  22. Dralle H, "Loss of the nerve monitoring signal during bilateral thyroid surgery", Br J Surg, 99, pp.1089~1095 (2012)[DOI]
  23. Thomusch O, "Validity of intra-operative neuromonitoring signals in thyroid surgery", Langenbecks Arch Surg, 389, pp.499~503 (2004)[DOI]
  24. Randolph GW, "Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement", Laryngoscope, 121(Suppl 1), pp.S1~S16 (2011)[DOI]
  25. Marusch F, "Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery", Br J Anaesth, 94, pp.596~600 (2005)[DOI]
  26. Melin M, "IONM-guided goiter surgery leading to two-stage thyroidectomy--indication and results", Langenbecks Arch Surg, 398, pp.411~418 (2013)[DOI]
  27. Perie S, "Value of recurrent laryngeal nerve monitoring in the operative strategy during total thyroidectomy and parathyroidectomy", Eur Ann Otorhinolaryngol Head Neck Dis, 130, pp.131~136 (2013)[DOI]
  28. Dionigi G, "Staged thyroidectomy: time to consider intraoperative neuromonitoring as standard of care", Thyroid, 23, pp.906~908 (2013)[DOI]
  29. Fontenot TE, "Does intraoperative nerve monitoring reliably aid in staging of total thyroidectomies?", Laryngoscope, 125, pp.2232~2235 (2015)[DOI]
  30. Dralle H, "Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery", World J Surg, 32, pp.1358~1366 (2008)[DOI]
  31. Casella C, "Does extralaryngeal branching have an impact on the rate of postoperative transient or permanent recurrent laryngeal nerve palsy?", World J Surg, 33, pp.261~265 (2009)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)