Advances in intraoperative neuromonitoring (IONM) in thyroid surgery have provided significant insights into recurrent laryngeal nerve function during thyroid surgery. Despite the limitations and necessary caution when using intraoperative monitors to interpret neural function, these technologies have been definite steps in the right direction for assessing neural integrity and safe surgical strategy during thyroid operations. The techniques discussed minimize the adverse sequelae of a variety of thyroid gland procedures, reducing the morbidity rates/risks in the perioperative period. Furthermore, it is likely that such monitoring will become a standard of care. Accurate, reliable and continuous monitoring is essential, and on-going large studies with definable end points will be necessary. The use of monitoring, such as continuous one, may improve cost efficiency by reducing permanent nerve injuries. A danger in this process, however, is the potential for public opinion, outside regulatory bodies, or medico-legal implications to drive change and enforce standards of care before appropriate data are available.

Abstract

Advances in intraoperative neuromonitoring (IONM) in thyroid surgery have provided significant insights into recurrent laryngeal nerve function during thyroid surgery. Despite the limitations and necessary caution when using intraoperative monitors to interpret neural function, these technologies have been definite steps in the right direction for assessing neural integrity and safe surgical strategy during thyroid operations. The techniques discussed minimize the adverse sequelae of a variety of thyroid gland procedures, reducing the morbidity rates/risks in the perioperative period. Furthermore, it is likely that such monitoring will become a standard of care. Accurate, reliable and continuous monitoring is essential, and on-going large studies with definable end points will be necessary. The use of monitoring, such as continuous one, may improve cost efficiency by reducing permanent nerve injuries. A danger in this process, however, is the potential for public opinion, outside regulatory bodies, or medico-legal implications to drive change and enforce standards of care before appropriate data are available.

참고문헌 (35)

  1. Singer MC, "Thyroidectomy-related malpractice claims", Otolaryngol Head Neck Surg, 146, pp.358~361 (2012)
  2. Abadin SS, "Malpractice litigation after thyroid surgery: the role of recurrent laryngeal nerve injuries, 1989–2009", Surgery, 148, pp.718~722 (2010)
  3. Randolph GW, "Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement", Laryngoscope, 121(Suppl 1), pp.S1~S16 (2011)
  4. Tomoda C, "Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery", World J Surg, 30, pp.1230~1233 (2006)
  5. Barczyński M, "Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy", Br J Surg, 96, pp.240~246 (2009)
  6. Dralle H, "Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery", World J Surg, 32, pp.1358~1366 (2008)
  7. Dralle H, "Loss of the nerve monitoring signal during bilateral thyroid surgery", Br J Surg, 99, pp.1089~1095 (2012)
  8. Godballe C, "Risk factors for recurrent nerve palsy after thyroid surgery: a national study of patients treated at Danish departments of ENT Head and Neck Surgery", Eur Arch Otorhinolaryngol, 271, pp.2267~2276 (2014)
  9. Adam MA, "Is there a minimum number of thyroidectomies a surgeon should perform to optimize patient outcomes?", Ann Surg, 265, pp.402~407 (2017)
  10. Lorenz K, "Results of intraoperative neuromonitoring in thyroid surgery and preoperative vocal cord paralysis", World J Surg, 38, pp.582~591 (2014)
  11. Lorenz K, "What are normal quantitative parameters of intraoperative neuromonitoring (IONM) in thyroid surgery?", Langenbecks Arch Surg, 395, pp.901~909 (2010)
  12. Brauckhoff M, "Latencies shorter than 3.5 ms after vagus nerve stimulation signify a nonrecurrent inferior laryngeal nerve before dissection", Ann Surg, 253, pp.1172~1177 (2011)
  13. Chiang FY, "Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation", World J Surg, 34, pp.223~229 (2010)
  14. Chiang FY, "The mechanism of recurrent laryngeal nerve injury during thyroid surgery--the application of intraoperative neuromonitoring", Surgery, 143, pp.743~749 (2008)
  15. Hamelmann WH, "A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery", Zentralbl Chir, 127, pp.409~413 (2002)
  16. Thomusch O, "Validity of intra-operative neuromonitoring signals in thyroid surgery", Langenbecks Arch Surg, 389, pp.499~503 (2004)
  17. Beldi G, "Evaluation of intraoperative recurrent nerve monitoring in thyroid surgery", World J Surg, 28, pp.589~591 (2004)
  18. Hermann M, "Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury", Ann Surg, 240, pp.9~17 (2004)
  19. Chan WF, "The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk", Surgery, 140, pp.866~872 (2006)
  20. Wong KP, "Systematic review and meta-analysis on intra-operative neuro-monitoring in high-risk thyroidectomy", Int J Surg, 38, pp.21~30 (2017)
  21. Melin M, "Postoperative vocal cord dysfunction despite normal intraoperative neuromonitoring: an unexpected complication with the risk of bilateral palsy", World J Surg, 38, pp.2597~2602 (2014)
  22. Schneider R, "Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury", Head Neck, 35, pp.1591~1598 (2013)
  23. Dionigi G, "Safety of neural monitoring in thyroid surgery", Int J Surg, 11(Suppl 1), pp.S120~S126 (2013)
  24. Echternach M, "Laryngeal complications after thyroidectomy: is it always the surgeon?", Arch Surg, 144, pp.149~153 (2009)
  25. Goretzki PE, "The impact of intraoperative neuromonitoring (IONM) on surgical strategy in bilateral thyroid diseases: is it worth the effort?", World J Surg, 34, pp.1274~1284 (2010)
  26. Dralle H, "Intraoperative neuromonitoring in thyroid surgery. Recommendations of the Surgical Working Group for Endocrinology", Chirurg, 84, pp.1049~1056 (2013)
  27. Dralle H, "Vocal cord paralysis after thyroid surgery: current medicolegal aspects of intraoperative neuromonitoring", Chirurg, 86, pp.698~706 (2015)
  28. Angelos P, "Recurrent laryngeal nerve monitoring: state of the art, ethical and legal issues", Surg Clin North Am, 89, pp.1157~1169 (2009)
  29. Horne SK, "Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy", Otolaryngol Head Neck Surg, 136, pp.952~956 (2007)
  30. Sturgeon C, "Neuromonitoring in thyroid surgery: attitudes, usage patterns, and predictors of use among endocrine surgeons", World J Surg, 33, pp.417~425 (2009)
  31. Timmermann W, "Effectiveness and results of intraoperative neuromonitoring in thyroid surgery. Statement of the Interdisciplinary Study Group on Intraoperative Neuromonitoring of Thyroid Surgery", Chirurg, 75, pp.916~922 (2004)
  32. Godballe C, "Registry of surgical results: organization and outcomes", 34th Annual Meeting of the European Thyroid Association (2009), European Thyroid Association
  33. Dionigi G, "Visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy: what about the costs?", World J Surg, 36, pp.748~754 (2012)
  34. Schneider R, "Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous or intermittent nerve monitoring", Br J Surg, 102, pp.1380~1387 (2015)
  35. Lin YC, "Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model", Laryngoscope, 125, pp.E283~E290 (2015)

관련 논문AI추천

Future Directions of Neural Monitoring in Thyroid Surgery김훈엽, 채영준, Che-Wei Wu, Gianlorenzo Dionigi, Xiaoli Liu대한내분비외과학회 · Journal of Endocrine Surgery2017 · 제17권 제3호The Consistency of Intraoperative Neural Monitoring in Thyroid Surgery김훈엽, 채영준, Bruno Galletti, Francesco Freni, Francesco Galletti, Gianlorenzo Dionigi, Özer Makay대한내분비외과학회 · Journal of Endocrine Surgery2018 · 제18권 제2호Intraoperative Neural Monitoring in Thyroid Surgery: Role and Responsibility of Surgeon김훈엽, 채영준, Che-Wei Wu, Eren Berber, Gianlorenzo Dionigi, Hui Sun, Marcin Barczynski, Özer Makay, Ralph P. Tufano대한내분비외과학회 · Journal of Endocrine Surgery2018 · 제18권 제1호Standards for Intraoperative Neuromonitoring in Thyroid Operations김훈엽, 채영준, Gianlorenzo Dionigi, Henning Dralle, Ralph Tufano, Xiaoli Liu대한내분비외과학회 · Journal of Endocrine Surgery2018 · 제18권 제1호Improving Safety of Neural Monitoring in Thyroid Surgery: Educational Considerations in Learning New ProcedureAntonina Catalfamo, Antonino Cancellieri, Antonio Giacomo Rizzo, Francesca Pia Pergolizzi, Gianlorenzo Dionigi, Giuseppinella Melita, Massimo Marullo, Valerio Fabiano, Vincenzo Bartolo대한내분비외과학회 · Journal of Endocrine Surgery2018 · 제18권 제1호갑상선 수술 중 신경 모니터링의 현재와 미래곽희용, 김훈엽대한내분비외과학회 · Journal of Endocrine Surgery2014 · 제14권 제2호

이 간행물의 다른 논문 (5건)