중증 폐쇄성 수면무호흡증에서 자동형 양압기와 고정형 양압기 치료의 비교 분석
Comparative Analysis of Automatic versus Fixed Positive Airway Pressure Therapy for Severe Obstructive Sleep Apnea
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background and Objectives The purposes of this study were to compare the purchase rateand adherence regarding the use of two machines, continuous positive airway pressure (CPAP)and automatic positive airway pressure (APAP), and to determine associated factors affecting thepurchase rate and adherence of PAP in the treatment of severe obstructive sleep apnea (OSA). Subjects and Method From March 2016 to December 2017, 45 patients diagnosed with severeOSA by polysomnography were enrolled in this study. Patients were prescribed CPAP orAPAP by one doctor and allowed to decide whether to purchase the machine after a one-monthlease period, which was identified as the purchase rate. Adherence was identified as using themachine 4 h/night on 70% of nights following the PAP therapy of three months. Results The adherence rate of CPAP (84%) was statistically and significantly higher than APAP(55%) (p=0.033). However, there was no significant difference in the adherence rate betweenCPAP (76%) and APAP (63%). The mean pressure and 95th percentile leak were 8.62 cm H2Oand 12.97 L/min in the CPAP and 10.55 cm H2O and 20.36 L/min in the APAP, respectively. Themean pressure and 95th percentile leak were significantly lower in CPAP than in APAP (p=0.010and p=0.014, respectively). Conclusion Although adherence was not significantly different, the purchase rate was significantlyhigher in the fixed CPAP than in APAP, which may have been influenced by high pressureand leak patients experienced when using the particular PAP machine.
Abstract
Background and Objectives The purposes of this study were to compare the purchase rateand adherence regarding the use of two machines, continuous positive airway pressure (CPAP)and automatic positive airway pressure (APAP), and to determine associated factors affecting thepurchase rate and adherence of PAP in the treatment of severe obstructive sleep apnea (OSA). Subjects and Method From March 2016 to December 2017, 45 patients diagnosed with severeOSA by polysomnography were enrolled in this study. Patients were prescribed CPAP orAPAP by one doctor and allowed to decide whether to purchase the machine after a one-monthlease period, which was identified as the purchase rate. Adherence was identified as using themachine 4 h/night on 70% of nights following the PAP therapy of three months. Results The adherence rate of CPAP (84%) was statistically and significantly higher than APAP(55%) (p=0.033). However, there was no significant difference in the adherence rate betweenCPAP (76%) and APAP (63%). The mean pressure and 95th percentile leak were 8.62 cm H2Oand 12.97 L/min in the CPAP and 10.55 cm H2O and 20.36 L/min in the APAP, respectively. Themean pressure and 95th percentile leak were significantly lower in CPAP than in APAP (p=0.010and p=0.014, respectively). Conclusion Although adherence was not significantly different, the purchase rate was significantlyhigher in the fixed CPAP than in APAP, which may have been influenced by high pressureand leak patients experienced when using the particular PAP machine.
참고문헌 (30)
- Partinen M, "Daytime sleepiness and vascular morbidity at seven-year follow-up in obstructive sleep apnea patients", Chest, 97(1), pp.27~32 (1990)
- Kales A, "Severe obstructive sleep apnea--II: Associated psychopathology and psychosocial consequences", J Chronic Dis, 38(5), pp.427~434 (1985)
- 김효열, "지속적상기도양압술의 순응도에 영향을 미치는 인자들", 대한이비인후-두경부외과학회지, 57(1), pp.7~14 (2014), 대한이비인후과학회[DOI]
- Nieto FJ, "Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study. Sleep Heart Health Study", JAMA, 283(14), pp.1829~1836 (2000)
- Kim J, "Prevalence of sleep-disordered breathing in middle-aged Korean men and women", Am J Respir Crit Care Med, 170(10), pp.1108~1113 (2004)
- Sullivan CE, "Reversal of obstructive sleep apnoea by continuous positive airway pressure applied through the nares", Lancet, 1(8225), pp.862~865 (1981)
- Parish JM, "Quality of life in bed partners of patients with obstructive sleep apnea or hypopnea after treatment with continuous positive airway pressure", Chest, 124(3), pp.942~947 (2003)
- Engleman HM, "Effect of CPAP therapy on daytime function in patients with mild sleep apnoea", hypopnoea syndrome, 1997, pp.52(2), 114~119
- Loube DI, "Indications for positive airway pressure treatment of adult obstructive sleep apnea patients : A consensus statement", Chest, 115(3), pp.863~866 (1999)
- Hoffstein V, "Review of oral appliances for treatment of sleepdisordered breathing", Sleep Breath, 11(1), pp.1~22 (2007)
- Weaver TE, "Self-efficacy in sleep apnea: Instrument development and patient perceptions of obstructive sleep apnea risk, treatment benefit, and volition to use continuous positive airway pressure", Sleep, 26(6), pp.727~732 (2003)
- Vital FM, "Non-invasive positive pressure ventilation (CPAP or bilevel NPPV) for cardiogenic pulmonary edema", Cochrane Database Syst Rev, (3), pp.CD005351~ (2008)
- Sin DD, "Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea:A population-based study", Chest, 121(2), pp.430~435 (2002)
- Nowak C, "Nasal obstruction and compliance to nasal positive airway pressure", Ann Otolaryngol Chir Cervicofac, 120(3), pp.161~166 (2003)
- Han EK, "The compliance and effect of CPAP in obstructive sleep apnea syndrome", Sleep Med Psychophysiol, 13(2), pp.52~58 (2006)
- Berkani M, "CPAP titration by an auto-CPAP device based on snoring detection: A clinical trial and economic considerations", Eur Respir J, 12(4), pp.759~763 (1998)
- Berry RB, "The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review", Sleep, 25(2), pp.148~173 (2002)
- d’Ortho MP, "Auto-titrating continuous positive airway pressure for treating adult patients with sleep apnea syndrome", Curr Opin Pulm Med, 10(6), pp.495~499 (2004)
- Randerath WJ, "Prospective randomized comparison of impedance-controlled autocontinuous positive airway pressure (APAP(FOT)) with constant CPAP", Sleep Med, 2(2), pp.115~124 (2001)
- Kribbs NB, "Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea", Am Rev Respir Dis, 147(4), pp.887~895 (1993)
- Teschler H, "Intelligent CPAP systems: Clinical experience", Thorax, 53(Suppl 3), pp.S49~S54 (1998)
- Basner RC, "Cardiovascular morbidity and obstructive sleep apnea", N Engl J Med, 356(17), pp.1751~1758 (2007)
- Dhillon S, "Sleep apnea, hypertension, and the effects of continuous positive airway pressure", Am J Hypertens, 18(5 Pt 1), pp.594~600 (2005)
- Aloia MS, "Treatment adherence and outcomes in flexible vs standard continuous positive airway pressure therapy", Chest, 127(6), pp.2085~2093 (2005)
- Kushida CA, "Practice parameters for the indications for polysomnography and related procedures : An update for 2005", Sleep, 28(4), pp.499~521 (2005)
- Parish JM, "Autotitration positive airway pressure therapy in patients with obstructive sleep apnea who are intolerant of fixed continuous positive airway pressure", Sleep Breath, 12(3), pp.235~241 (2008)
- Valentin A, "Air leak is associated with poor adherence to autoPAP therapy", Sleep, 34(6), pp.801~806 (2011)
- Lebret M, "Determinants of Unintentional Leaks During CPAP Treatment in OSA", Chest, 153(4), pp.834~842 (2018)
- Genta PR, "Sealing the leak: A step forward in improving CPAP adherence", Chest, 153(4), pp.774~775 (2018)
- Woehrle H, "Effect of a patient engagement tool on positive airway pressure adherence: Analysis of a German healthcare provider database", Sleep Med, 41, pp.20~26 (2018)