A 58-year-old male patient presented with acute alcohol-induced severe necrotizing pancreatitis. He reported a symptomatic acute necrotic collection in the pancreatic head. No improvements were observed despite one week of antimicrobial therapy. Endoscopic ultrasound-guided drainage via the superior duodenal angle was conducted and a lumen-apposing metal stent (LAMS) was placed. He had an obstructive jaundice progression 3 days postintervention. Endoscopic retrograde cholangiography showed that the cystic side flange of the LAMS caused the distal bile duct smooth stricture. The jaundice improved immediately after the placement of plastic stent in the bile duct, and the LAMS could be removed on the 15th day after placement. The plastic stent was removed after 4 months, and the biliary stricture improved, with no recurrence of jaundice. Here, we report a case of successful conservative treatment of a benign biliary stricture caused by the distal flange of the LAMS.

Abstract

A 58-year-old male patient presented with acute alcohol-induced severe necrotizing pancreatitis. He reported a symptomatic acute necrotic collection in the pancreatic head. No improvements were observed despite one week of antimicrobial therapy. Endoscopic ultrasound-guided drainage via the superior duodenal angle was conducted and a lumen-apposing metal stent (LAMS) was placed. He had an obstructive jaundice progression 3 days postintervention. Endoscopic retrograde cholangiography showed that the cystic side flange of the LAMS caused the distal bile duct smooth stricture. The jaundice improved immediately after the placement of plastic stent in the bile duct, and the LAMS could be removed on the 15th day after placement. The plastic stent was removed after 4 months, and the biliary stricture improved, with no recurrence of jaundice. Here, we report a case of successful conservative treatment of a benign biliary stricture caused by the distal flange of the LAMS.

관련 논문AI추천

Fracture of Self-Expandable Metal Stent during Endoscopic Removal in Benign Biliary Stricture백창렬, 양진모, 이강문, 정우철, 주규래대한소화기내시경학회 · Clinical Endoscopy2013 · 제46권 제1호Duodenal Stricture due to Necrotizing Pancreatitis following Endoscopic Ultrasound-Guided Ethanol Ablation of a Pancreatic Cyst: A Case Report백우현, 이상협, Ji Kon Ryu, Jin Ho Choi, Jung Won Chun, Yong-Tae Kim대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제5호Effcacy and Safety of Lumen-Apposing Stents for Management of Pancreatic Fluid Collections in a Community Hospital SettingAbdelkader Chaar, Babu P. Mohan, Mohammed Barawi, Rajat Garg, Susan Szpunar대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제4호Refractory benign biliary stricture due to chronic pancreatitis in two patients treated using endoscopic ultrasound-guided choledochoduodenostomy fistula creation: case reportsKazuo Hara, Nobumasa Mizuno, Nozomi Okuno, Shin Haba, Sho Ishikawa, Takafumi Yanaidani, Takamichi Kuwahara, Yasuhiro Kuraishi대한소화기내시경학회 · Clinical Endoscopy2024 · 제57권 제1호Advances in self-expandable metal stents for endoscopic ultrasound-guided interventionsDong Kee Jang, Dong Wook Lee, Kwang Bum Cho, Seong-Hun Kim, Sundeep Lakhtakia대한소화기내시경학회 · Clinical Endoscopy2024 · 제57권 제5호Stent occlusion in endoscopic ultrasound-guided gallbladder drainage from bleeding mitigated by double pigtail plastic stent deployment within lumen apposing metal stentMurali Dharan소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2021 · 제10권 제4호

이 간행물의 다른 논문 (8건)

Emergent treatment using balloon-assisted ERCP versus EUS-guided drainage for acute cholangitis in patients with surgically altered anatomyAshida Reiko, Ishihara Tomokazu, Sugihara Yuto, Nakahata Akiya, Morishita Hiromu, Shishimoto Takahiro, Kawaji Yuki, Tamura Takashi, Yamashita Yasunobu, Itonaga Masahiro, Kitano Masayukipp. 2-8Novel technique for endoscopic ultrasound-guided gallbladder drainage to skip the needle tract dilation step: Efficacy of a 6-mm antimigration metal stent with a thin, tapered delivery catheterKawaji Yuki, Nuta Junya, Hatamaru Keiichi, Kitano Masayuki, Itonaga Masahiro, Yamashita Yasunobu, Tamura Takashipp. 9-14Endoscopic ultrasound-guided drainage of postoperative pancreatic fluid collectionsKudo Akiharu, Nishiyama Shigeru, Hisa Takeshi, Ego Aki, Sakata Shogo, Ito Yui, Yamada Takahiro, Osera Shozo, Fukushima Hideki, Ishizaki Shunta, Hamura Ryoga, Tsunematsu Masashi, Abe Kyohei, Shirai Yoshihiro, Onda Shinjipp. 15-19Malignant biliary obstruction treated with preoperative endoscopic ultrasound-guided hepaticogastrostomy: A case reportFukumoto Mai, Kanemitsu-Okada Kozue, Kuroda Taira, Kitahata Shogo, Onishi Kei, Izumoto Hirofumi, Murakami Taisei, Murakawa Kazuya, Kawamura Tomoe, Matsuoka Kana, Matsuda Takuya, Nakamura Ayaka, Kimura Yuka, Ninomiya Tomoyuki, Hiraoka Atsushi, Hanaoka Jun, Miyata Hideki, Tsubouchi Eiji, Tada Fujimasapp. 20-23Difficult case of endoscopic ultrasonography-guided choledochogastrostomy salvaged using a stiff guidewireKomaki Takamitsu, Takenaka Mamoru, Kudo Masatoshi, Narikawa Takio, Kamata Kenpp. 28-31