Abstract
Background : Due to the westernization of living environments in Korea, a number of allergy patients are greatly increasing. External quality control assessments are difficult for allergy tests due to the lack of reference methods. We surveyed the current status of allergy tests performed in medical laboratories in Korea to prepare for an external quality control assessment in the near future. Methods : We conducted a survey on internal and external quality control trials, calibrations and its intervals, medical staffs, analyzers in use, an average number of tests per months, and report formats. Results : Among the 85 laboratories surveyed, 61 were doing allergy tests including 6 reference laboratories. There were two different types of analyzers (1) qualitative or semi-quantitative and (2) quantitative. These analyzers use either chemiluminescent or immunoblot method. Fifty-five laboratories were using ‘qualitative or semi-quantitative’ analyzers as a screening test and 31 laboratories were using quantitative analyzers. Most of the laboratories were only doing an internal quality control assessment included in the test kits. Excepting a few laboratories, calibrations were not done. About 34 laboratories reported numerical values with interpretative reports prepared by laboratory medical doctors. Conclusions : The necessity of external quality control assessment has become an issue for improving the quality of allergy tests. But due to the lack of standardization, it is difficult to carry out external quality control assessments. By grouping the laboratories in terms of the type of analyzers, we could overcome the problem of analyzer variations and launch an external quality control assessment program in the near future. (Korean J Lab Med 2008;28:124-9)
참고문헌 (15)
- Lim, HS, "Allergen patterns using MAST CLA test in Korean pediatric patients", Korean J Clin Pathol, 21, pp.292~297 (2001)
- Brown CR, "Simultaneous determination of total IgE and allergen-specific IgE in serum by the MAST chemiluminescent assay system", Clin Chem, 31, pp.1500~1505 (1985)
- Taylor G, "Charles Harrison Blackley", Clin Allergy, 3, pp.103~108 (1973)
- Reddy PM, "Reappraisal of intracutaneous tests in the diagnosis of reaginic allergy", J Allergy Clin Immunol, 61, pp.36~41 (1978)
- Ishizaka K, "Physicochemical properties of reaginic antibody. 1. Association of reaginic activity with an immunoglobulin other than gamma A- or gamma G-globulin", J Allergy, 37, pp.169~185 (1966)
- Wide L, "Diagnosis of allergy by an invitro test for allergen antibodies", Lancet, 2, pp.1105~1107 (1967)
- Ali M, "Assay of IgE antibodies against June and Timothy grasses by an immunoperoxidase technique", Clin Allergy, 10, pp.203~209 (1980)
- Ali M, "Correlation of the diagnostic skin test with the immunoperoxidase assay in ragweed hypersensitivity", Ann Allergy, 45, pp.63~66 (1980)
- Tsay YG, "IgE fluoroallergosorbent (IgE FASTTM) test: Concept and clinical applications", Immunol Allergy Prac, 6, pp.169~174 (1984)
- Bonetti SM, "Relationships between skin prick test, radioallergosorbent test, and chemiluminescent assays in allergic children", Ann Allergy, 66, pp.137~141 (1991)
- Ownby DR, "Comparison of MAST with radioallergosorbent and skin tests for diagnosis of allergy in children", Am J Dis Child, 140, pp.45~48 (1986)
- Curran WS, "The incidence of immediately reacting skin tests in a normal adult population", Ann Intern Med, 55, pp.777~783 (1961)
- DeVore NC, "Quantification and standardization of allergens in: Manuals of molecular and clinical immunology", pp.937~938 (2006), ASM Press
- Hamilton RG, "Immunological methods in the diagnostic allergy clinical and research laboraotry in: Manuals of molecular and clinical immunology", pp.960~ (2006), ASM Press
- "Diagnostic immunology resource committee. Diagnostic allergy survey SE-A 2007 participant summary. Northfield, IL: College of American Pathologists. 2007", ~ (2007)