수혈 전 검사 장비인 AutoVue Innova와 Techno TwinStation의 평가

Evaluation of Two Automated Instruments for Pre-transfusion Testing: AutoVue Innova and Techno TwinStation

1

조회

0

다운로드

15

인용

0

참고문헌

키워드

주제분류병리학

초록

Background : Despite the advances in total laboratory automation, a considerable amount of work in blood banks is still done using outdated manual methods. Some automated pre-transfusion testing instruments have recently been developed. Of these, we evaluated and compared the AutoVue Innova (Ortho, USA) and the Techno TwinStation (DiaMed AG, Switzerland). Methods : Forward and reverse ABO/Rh typing and unexpected antibody screening and identification tests were performed on 4,628 samples using the manual method and the two automated instruments. Two different anticoagulants (EDTA and citrate) were compared in ABO/Rh typing and unexpected antibody screening tests. Titrating studies were conducted on the following 7 dilutions using 5 samples of irregular antibodies with anti-E, anti-E & -c, anti-D, and anti-Lea with anti-Fya: 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, and 1:128. The test throughput per hour, the time required to perform 1 and 100 tests, and a simulation test for total events occurring in 1 day were also measured. Results : No erroneous results were reported between the two instruments and the manual method. Discrepancies observed in 10 cases (0.4%) of ABO/Rh typing were of higher intensity with AutoVue Innova than with the manual method. AutoVue Innova exhibited the highest sensitivity in the titrating study and throughput performance compared with the manual method and the Techno TwinStation. Especially in the throughput and time required to complete 100 antibody screening tests, AutoVue Innova had a 3.3- and 3.5-fold higher performance, respectively, than Techno TwinStation. Conclusions : Because both of the two fully automated instruments (AutoVue Innova and Techno TwinStation) had high levels of accuracy and performance, it is expected that use of fully automated instruments will reduce human labor, turnaround time, and operator error in the blood bank. (Korean J Lab Med 2008;28:214-20)

Abstract

Background : Despite the advances in total laboratory automation, a considerable amount of work in blood banks is still done using outdated manual methods. Some automated pre-transfusion testing instruments have recently been developed. Of these, we evaluated and compared the AutoVue Innova (Ortho, USA) and the Techno TwinStation (DiaMed AG, Switzerland). Methods : Forward and reverse ABO/Rh typing and unexpected antibody screening and identification tests were performed on 4,628 samples using the manual method and the two automated instruments. Two different anticoagulants (EDTA and citrate) were compared in ABO/Rh typing and unexpected antibody screening tests. Titrating studies were conducted on the following 7 dilutions using 5 samples of irregular antibodies with anti-E, anti-E & -c, anti-D, and anti-Lea with anti-Fya: 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, and 1:128. The test throughput per hour, the time required to perform 1 and 100 tests, and a simulation test for total events occurring in 1 day were also measured. Results : No erroneous results were reported between the two instruments and the manual method. Discrepancies observed in 10 cases (0.4%) of ABO/Rh typing were of higher intensity with AutoVue Innova than with the manual method. AutoVue Innova exhibited the highest sensitivity in the titrating study and throughput performance compared with the manual method and the Techno TwinStation. Especially in the throughput and time required to complete 100 antibody screening tests, AutoVue Innova had a 3.3- and 3.5-fold higher performance, respectively, than Techno TwinStation. Conclusions : Because both of the two fully automated instruments (AutoVue Innova and Techno TwinStation) had high levels of accuracy and performance, it is expected that use of fully automated instruments will reduce human labor, turnaround time, and operator error in the blood bank. (Korean J Lab Med 2008;28:214-20)

참고문헌 (6)

  1. Mcpherson RA, "Henry’s clinical diagnosis and management by laboratory methods", pp.58~ (2007), Saunders
  2. Recommendations for evaluation, validation and implementation of new techniques for blood grouping, antibody screening and cross-matching, "British Committee for Standards in Haematology, Blood Transfusion Task Force", Transfus Med, 5, pp.145~150 (1995)
  3. Han KS, "Transfusion medicine", pp.360~ (2006), Korea Medical Book Pubisher
  4. Burtis CA, "Tietz textbook of clinical chemistry and molecular diagnostics", pp.492~493 (2006), Saunders
  5. Morelati F, "Evaluation of a new automated instrument for pretransfusion testing", Transfusion, 38, pp.959~965 (1998)
  6. Han KS, "Irregular blood group antibodies in Korean", Korean J Hematol, 24, pp.145~153 (1989)

관련 논문AI추천

ABO-RhD 혈액형 검사와 비예기항체 선별검사를 위한 혈액은행 자동화장비 IH-500과 VISION Max의 평가구선회, 권계철, 김선영, 김지명, 박유미, 임영애, 임진숙대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제4호교차시험 검사를 위한 혈액은행 자동화 장비 ORTHO VISION의 평가구모세, 구선회, 권계철, 김선영, 김지명, 임진숙대한진단검사의학회 · Laboratory Medicine Online2019 · 제9권 제4호Evaluation of the Automated Immunohematology Analyzer DAYMATE M김용구, 송영선, 유재은, 유해인, 이규형, 이승옥, 최현유, 제갈동욱대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제4호Economic and Workflow Analysis of a Blood Bank Automated System김형회, 신경화, 이은엽, 장철훈대한진단검사의학회 · Annals of Laboratory Medicine2013 · 제33권 제4호Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies김형회, 김혜림, 신경화, 이주미, 이현지, 장철훈, 조수연대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제2호Development of Cryopreserved Red Blood Cell Panels as Biological Reference Standards for Performance Evaluation of ABO and D Blood Grouping Reagents고대현, 김신영, 김현옥, 임지향, 조윤경, 최승준대한진단검사의학회 · Laboratory Medicine Online2022 · 제12권 제1호

이 간행물의 다른 논문 (12건)