Incidental Identification of Plasmodium vivax During Routine Complete Blood Count Analysis Using the UniCel DxH 800
0
조회
0
다운로드
0
인용
0
참고문헌
초록
Dear Editor, A complete blood count (CBC) is one of the most frequently requested diagnostic tests in medical laboratories. This test is indicated, among others, for febrile patients who may be infected with malaria [1]. Currently available automated hematology analyzers are not designed to detect malaria-related signals. The incorporation of a ‘malaria flag’ into modern analyzers would allow for the development of an automated and adjuvant diagnostic tool for febrile patients who may have malaria, especially for patients with low pre-test expectation of the disease in non-endemic regions.
Abstract
Dear Editor, A complete blood count (CBC) is one of the most frequently requested diagnostic tests in medical laboratories. This test is indicated, among others, for febrile patients who may be infected with malaria [1]. Currently available automated hematology analyzers are not designed to detect malaria-related signals. The incorporation of a ‘malaria flag’ into modern analyzers would allow for the development of an automated and adjuvant diagnostic tool for febrile patients who may have malaria, especially for patients with low pre-test expectation of the disease in non-endemic regions.
참고문헌 (12)
- Mace KE, "Malaria Surveillance - United States, 2014", MMWR Surveill Summ, 66, pp.1~24 (2017)
- Choi SJ, "Severe fever with thrombocytopenia syndrome in South Korea, 2013-2015", PLoS Negl Trop Dis, 10, pp.e0005264~ (2016)[DOI]
- Lee HK, "Sensitive detection and accurate monitoring of Plasmodium vivax parasites on routine complete blood count using automatic blood cell analyzer (DxH800(TM))", Int J Lab Hematol, 34, pp.201~207 (2012)[DOI]
- Kimura M, "Species-specific PCR detection of malaria parasites by microtiter plate hybridization: clinical study with malaria patients", J Clin Microbiol, 33, pp.2342~2346 (1995)
- Ciceron L, "Development of a Plasmodium PCR for monitoring efficacy of antimalarial treatment", J Clin Microbiol, 37, pp.35~38 (1999)
- Suh IB, "Evaluation of the Abbott Cell-Dyn 4000 hematology analyzer for detection and therapeutic monitoring of Plasmodium vivax in the Republic of Korea", Trop Med Int Health, 8, pp.1074~1081 (2003)[DOI]
- Fourcade C, "Automated detection of malaria by means of the haematology analyser Coulter GEN.S", Clin Lab Haematol, 26, pp.367~372 (2004)[DOI]
- Sharma P, "LH750 hematology analyzers to identify malaria and dengue and distinguish them from other febrile illnesses", Int J Lab Hematol, 36, pp.45~55 (2014)[DOI]
- Huh HJ, "Malaria detection with the Sysmex XE-2100 hematology analyzer using pseudoeosinophilia and abnormal WBC scattergram", Ann Hematol, 87, pp.755~759 (2008)[DOI]
- McPherson RA, "Henry's Clinical Diagnosis and Management by Laboratory Methods E-Book" (2017), Elsevier Health Sciences
- Campuzano-Zuluaga G, "Automated haematology analysis to diagnose malaria", Malar J, 9, pp.346~ (2010)[DOI]
- Sharma S, "Abnormal WBC scattergram: a clue to the diagnosis of malaria", Hematology, 18, pp.101~105 (2013)[DOI]
