본문 바로가기
KERD
논문KCI 등재

Fracture resistance of endodontically treated canines restored with different sizes of fiber post and all-ceramic crowns

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS. Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS. Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION. In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth. [J Adv Prosthodont 2016;8:158-66]

Abstract

PURPOSE. The aim of this study was to determine the fracture resistance and the mode of fracture of endodontically treated teeth restored with different fiber posts and all-ceramic crowns. MATERIALS AND METHODS. Two glass fiber reinforced post systems in two different sizes and polyethylene fiber ribbon in two different thicknesses (n=10) were used. The specimens, restored with all-ceramic crowns, were subjected to a compressive load (in N) delivered at a 130-degree angle to the long axis until a fracture could be noted. The results were analyzed statistically with a One-Way ANOVA test (P<.05). RESULTS. Statistically significant differences were observed between the mean fracture resistance values of Postec, Snowlight, and Kerr Connect thin specimens (P<.0095). The Postec results (395.70 N) were found to be significantly higher than the others. No statistical difference was observed among the thick specimens (P<.2657). The mean fracture resistance values of the Snowlight thick samples were found to be higher than those of the Snowlight thin samples. The specimens were always fractured around the cemento-enamel junction at the palatinal side. No post fracture was observed for the thin Snowlight and Kerr Connect specimens or for the thick Postec and Kerr Connect specimens. Among the common failure types of the specimens, the worst was observed to be the root fracture failure. The highest post dislodgement failure result (80%) was obtained from the thin Kerr Connect specimen. CONCLUSION. In terms of optimizing fracture resistance, the fiber post size selection should be done according to the forces applied to the restored teeth. [J Adv Prosthodont 2016;8:158-66]

참고문헌 (43)

  1. Robbins JW, "Restoration of the endodontically treated tooth", Dent Clin North Am, 46, pp.367~384 (2002)
  2. Torbjörner A, "Survival rate and failure characteristics for two post designs", J Prosthet Dent, 73, pp.439~444 (1995)
  3. Viguie G, "Epoxy", carbon composite resins in dentistry: mechanical properties related to fiber reinforcements, 1994, pp.72, 245~249
  4. Lima AF, "Influence of ferrule preparation with or without glass fiber post on fracture resistance of endodontically treated teeth", J Appl Oral Sci, 18, pp.360~363 (2010)
  5. Lassila LV, "Flexural properties of fiber reinforced root canal posts", Dent Mater, 20, pp.29~36 (2004)
  6. Maroulakos G, "Fracture resistance of compromised endodontically treated teeth restored with bonded post and cores: An in vitro study", J Prosthet Dent, 114, pp.390~397 (2015)
  7. Bateman G, "Fibre-based post systems: a review", Br Dent J, 195, pp.43~48 (2003)
  8. Fragou T, "The effect of ferrule on the fracture mode of endodontically treated canines restored with fibre posts and metal-ceramic or all-ceramic crowns", J Dent, 40, pp.276~285 (2012)
  9. Duret B, "Long-life physical property preservation and postendodontic rehabilitation with the Composipost", Compend Contin Educ Dent Suppl, 20, pp.S50~S56 (1996)
  10. Fredriksson M, "A retrospective study of 236 patients with teeth restored by carbon fiber-reinforced epoxy resin posts", J Prosthet Dent, 80, pp.151~157 (1998)
  11. Ferrari M, "Retrospective study of the clinical performance of fiber posts", Am J Dent, 13, pp.9B~13B (2000)
  12. Balbosh A, "Effect of surface treatment on retention of glass-fiber endodontic posts", J Prosthet Dent, 95, pp.218~223 (2006)
  13. Rudo DN, "Physical behaviors of fiber reinforcement as applied to tooth stabilization", Dent Clin North Am, 43, pp.7~35 (1999)
  14. Turker SB, "Prospective clinical trial of polyethylene fiber ribbon-reinforced, resin composite post-core buildup restorations", Int J Prosthodont, 20, pp.55~56 (2007)
  15. Turner CH, "Cement distribution during post cementation", J Dent, 9, pp.231~239 (1981)
  16. Mendoza DB, "Root reinforcement with a resin-bonded preformed post", J Prosthet Dent, 78, pp.10~14 (1997)
  17. Mannocci F, "Intermittent loading of teeth restored using quartz fiber, carbon-quartz fiber, and zirconium dioxide ceramic root canal posts", J Adhes Dent, 1, pp.153~158 (1999)
  18. Stockton LW, "Factors affecting retention of post systems: a literature review", J Prosthet Dent, 81, pp.380~385 (1999)
  19. Sahafi A, "Retention and failure morphology of prefabricated posts", Int J Prosthodont, 17, pp.307~312 (2004)
  20. Cohen BI, "Fracture strength of three different core materials in combination with three different endodontic posts", Int J Prosthodont, 7, pp.178~182 (1994)
  21. Yaman P, "Effect of core materials on stress distribution of posts", J Prosthet Dent, 68, pp.416~420 (1992)
  22. Sadek FT, "Bond strength performance of different resin composites used as core materials around fiber posts", Dent Mater, 23, pp.95~99 (2007)
  23. Isidor F, "The influence of post length and crown ferrule length on the resistance to cyclic loading of bovine teeth with prefabricated titanium posts", Int J Prosthodont, 12, pp.78~82 (1999)
  24. Sokol DJ, "Effective use of current core and post concepts", J Prosthet Dent, 52, pp.231~234 (1984)
  25. Standlee JP, "The retentive and stress-distributing properties of a threaded endodontic dowel", J Prosthet Dent, 44, pp.398~404 (1980)
  26. Holmes DC, "Influence of post dimension on stress distribution in dentin", J Prosthet Dent, 75, pp.140~147 (1996)
  27. Sirimai S, "An in vitro study of the fracture resistance and the incidence ofvertical root fracture of pulpless teeth restored with six post-and-coresystems", J Prosthet Dent, 81, pp.262~269 (1999)
  28. Kelly JR, "Approaching clinical relevance in failure testing of restorations", J Prosthet Dent, 81, pp.652~661 (1999)
  29. Assif D, "Effect of post design n resistance to fracture of endodontically treated teeth with complete crowns", J Prosthet Dent, 69, pp.36~40 (1993)
  30. Pereira JR, "Effect of a crown ferrule on the fracture resistance of endodontically treated teeth restored with prefabricated posts", J Prosthet Dent, 95, pp.50~54 (2006)
  31. Cormier CJ, "In vitro comparison of the fracture resistance and failure mode of fiber, ceramic, and conventional post systems at various stages of restoration", J Prosthodont, 10, pp.26~36 (2001)
  32. Al-Wahadni AM, "Fracture resistance of teeth restored with dif-ferent post systems: in vitro study", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 106, pp.e77~e83 (2008)
  33. Stricker EJ, "Influence of different posts and cores on marginal adaptation, fracture resistance, and fracture mode of composite resin crowns on human mandibular premolars. An in vitro study", J Dent, 34, pp.326~335 (2006)
  34. Akkayan B, "An in vitro study evaluating the effect of ferrule length on fracture resistance of endodontically treated teeth restored with fiber-reinforced and zirconia dowel systems", J Prosthet Dent, 92, pp.155~162 (2004)
  35. Tan PL, "In vitro fracture resistance of endodontically treated central incisors with varying ferrule heights and configurations", J Prosthet Dent, 93, pp.331~336 (2005)
  36. Eskitaşcioğlu G, "Evaluation of two post core systems using two different methods (fracture strength test and a finite elemental stress analysis)", J Endod, 28, pp.629~633 (2002)
  37. Giovani AR, "In vitro fracture resistance of glass-fiber and cast metal posts with different lengths", J Prosthet Dent, 101, pp.183~188 (2009)
  38. de Oliveira JA, "Fracture resistance of endodontically treated teeth with different heights of crown ferrule restored with prefabricated carbon fiber post and composite resin core by intermittent loading", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 106, pp.e52~e57 (2008)
  39. Ma PS, "Load fatigue of teeth with different ferrule lengths, restored with fiber posts, composite resin cores, and all-ceramic crowns", J Prosthet Dent, 102, pp.229~234 (2009)
  40. Goodacre CJ, "Tooth preparations for complete crowns: an art form based on scientific principles", J Prosthet Dent, 85, pp.363~376 (2001)
  41. Kovarik RE, "Fatigue life of three core materials under simulated chewing conditions", J Prosthet Dent, 68, pp.584~590 (1992)
  42. Lyons MF, "A preliminary electromyographic study of bite force and jaw-closing muscle fatigue in human subjects with advanced tooth wear", J Oral Rehabil, 17, pp.311~318 (1990)
  43. Marchionatti AM, "Influence of periodontal ligament simulation on bond strength and fracture resistance of roots restored with fiber posts", J Appl Oral Sci, 22, pp.450~458 (2014)

관련 논문AI추천

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolarsHabib Hajmiragha, Hamid Reza Rajati, Mohamadjavad Kharazifard, Sareh Habibzadeh, Shima Esmailzadeh대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Fracture resistance of upper central incisors restored with different posts and coresKamran Amirian Chaijan, Saeid Tavanafar, Saeid Tavanafar,대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제3호A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber postcore retained conventional crownsChaoyang Sun, Erdong Gao, Hongbo Li, Jing Guo, Xuesheng Li, Zhiming Wang대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제6호Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core김영회, 이종혁대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제1호A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro studyChetana S. Makade, Ganesh K. Meshram, Manjusha Warhadpande, Pravinkumar G. Patil대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제2호Effect of ferrule on the fracture resistance of mandibular premolars with prefabricated posts and cores김애라, 박상원, 양홍서, 임현필대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제5호

이 간행물의 다른 논문 (11건)