Evaluation of polymethyl methacrylate resin mechanical properties with incorporated halloysite nanotubes
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young’ modulus. MATERIALS AND METHODS. Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young’ modulus and hardness values were measured. One-way ANOVA and Tukey’ test were used for comparison (P<.05). RESULTS. At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness valuesbut no significant increase in both flexural strength and Young’ modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young’ modulus values compared to those of the control group. CONCLUSION. Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction.
Abstract
PURPOSE. This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young’ modulus. MATERIALS AND METHODS. Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young’ modulus and hardness values were measured. One-way ANOVA and Tukey’ test were used for comparison (P<.05). RESULTS. At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness valuesbut no significant increase in both flexural strength and Young’ modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young’ modulus values compared to those of the control group. CONCLUSION. Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction.
참고문헌 (34)
- Jagger DC, "The reinforcement of dentures", J Oral Rehabil, 26, pp.185~194 (1999)
- Kim SH, "The effect of reinforcement with woven E-glass fibers on the impact strength of complete dentures fabricated with high-impact acrylic resin.", J Prosthet Dent, 91, pp.274~280 (2004)
- Vallittu PK, "Effect of metal strengthener’s surface roughness on fracture resistance of acrylic denture base material", J Oral Rehabil, 19, pp.385~391 (1992)
- Vallittu PK, "Effect of some properties of metal strengtheners on the fracture resistance of acrylic denture base material construction", J Oral Rehabil, 20, pp.241~248 (1993)
- John J, "Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers", J Prosthet Dent, 86, pp.424~427 (2001)
- Chen SY, "Effects of fillers on fiber reinforced acrylic denture base resins", Mid Taiwan J Med, 9, pp.203~210 (2004)
- Zarb GA, "Prosthodontic Treatment for Edentulous Patients", pp.195~ (2004), Elsevier
- Ellakwa AE, "Effect of aluminum oxide addition on the flexural strength and thermal diffusivity of heat-polymerized acrylic resin", J Prosthodont, 17, pp.439~444 (2008)
- Ayad NM, "Effect of Reinforcement of High impact acrylic resin with zirconia on some physical and mechanical properties", Rev Clin Pesq Odontol, 4, pp.145~151 (2008)
- Panyayong W, "Reinforcement of acrylic resins for provisional fixed restorations. Part III: Effects of addition of titania and zirconia mixtures on some mechanical and physical properties", Biomed Mater eng, 12, pp.327~343 (2002)
- Saad-Eldeen MA, "Effect of zirconium oxide reinforcement on epithelial oral mucosa, Immunoglobulin and surface roughness of complete acrylic heat-cured denture", Egypt Dent Associat, 53, pp.941~946 (2007)
- Tinschert J, "Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study", Int J Prosthodont, 14, pp.231~238 (2001)
- Abdel-Samad A, "Evaluation of the effect of zirconium oxide on wear resistance and hardness of acrylic teeth", Egypt Dent Associat, 55, pp.639~643 (2009)
- Minamizato T, "Slip-cast zirconia dental roots with tunnels drilled by laser process", J Prosthet Dent, 63, pp.677~684 (1990)
- William D, "Materials science and engineering: An introduction", pp.532~533 (1997), John Wiley & Sons Incorporation
- Radford DR, "Adherence of Candida albicans to denture-base materials with different surface finishes", J Dent, 26, pp.577~583 (1998)
- Verran J, "Retention of Candida albicans on acrylic resin and silicone of different surface topography", J Prosthet Dent, 77, pp.535~539 (1997)
- Powers JM, "Craig’s Restorative Dental Materials", pp.79~ (2006), Elsevier
- Joussein E, "Halloysite clay minerals - a review", Clay Minerals, 40, pp.383~426 (2005)
- Hope E, "Surface tension and the morphology of halloysite", The American Mineralogist, 49, pp.859~863 (1964)
- Vergaro V, "Cytocompatibility and uptake of halloysite clay nanotubes", Biomacromolecules, 11, pp.820~826 (2010)
- Guimarães L, "Structural, electronic, and mechanical properties of singlewalled halloysite nanotube models", J Phys Chem C, 114, pp.11358~11363 (2010)
- Guimarães L, "Imogolite nanotubes: stability, electronic, and mechanical properties", ACS Nano, 1, pp.362~368 (2007)
- Ye YP, "Interlaminar properties of carbon fiber composites with halloysite nanotube-toughened epoxy matrix", Compos Sci Technol, 71, pp.717~723 (2011)
- Sehajpal SB, "Effect of metal fillers on some physical properties of acrylic resin", J Prosthet Dent, 61, pp.746~751 (1989)
- International Organization for Standardization, "Specification 1567: Denture Base Polymers", 1~9 (1988)
- Takahashi Y, "Flexural strength at the proportional limit of a denture base material relined with four different denture reline materials", Int J Prosthodont, 10, pp.508~512 (1997)
- Vallittu PK, "Effect of water storage on the flexural properties of E-glass and silica fiber acrylic resin composite", Int J Prosthodont, 11, pp.340~350 (1998)
- Machado AL, "Hardness and surface roughness of reline and denture base acrylic resins after repeated disinfection procedures", J Prosthet Dent, 102, pp.115~122 (2009)
- Chen Q, "Fabrication and evaluation of Bis-GMA", TEGDMA dental resins, Dent Mater, pp.2012, 28[DOI]
- Leinfelder KF, "Five-year clinical evaluation of anterior and posterior restorations of composite resin", Oper Dent, 12, pp.52~78 (1980)
- Xu HH, "Dental composite resins containing silica-fused ceramic single-crystalline whiskers with various filler levels", J Dent Res, 78, pp.1304~1311 (1999)
- Xu HH, "Strengthening composite resin restorations with ceramic whisker reinforcement", Pract Periodontics Aesthet Dent, 12, pp.111~116 (2000)
- Vojdani M, "Effects of aluminum oxide addition on the flexural strength, surface hardness, and roughness of heat-polymerized acrylic resin", J Dent Sci, 7, pp.238~244 (2012)
