STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants (diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, 2nd stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (P = .46) and RFA values. The mean BIC % in the Mg-implants was 54.5 ± 8.4%. The mean BIC % in the turned implant was 45.3 ± 12.2%. These differences between the Mg-implant and control implant were statistically significant (P = .005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact (BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

Abstract

STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants (diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, 2nd stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (P = .46) and RFA values. The mean BIC % in the Mg-implants was 54.5 ± 8.4%. The mean BIC % in the turned implant was 45.3 ± 12.2%. These differences between the Mg-implant and control implant were statistically significant (P = .005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact (BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

참고문헌 (37)

  1. Brånemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg Suppl, 16, pp.1~132 (1977)
  2. Randow K, "Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study", Clin Oral Implants Res, 10, pp.8~15 (1999)
  3. Albrektsson T, "The longterm efficacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  4. Albrektsson T, "State of the art in oral implants", J Clin Periodontol, 18, pp.474~481 (1991)
  5. Brunski JB, "Avoid pitfalls of overloading and micromotion of intraosseous implants", Dent Implantol Update, 4, pp.77~81 (1993)
  6. Szmukler-Moncler S, "Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature", J Biomed Mater Res, 43, pp.192~203 (1998)
  7. Gomes A, "Immediate loading of a single hydroxyapatite-coated threaded root form implant: a clinical report", J Oral Implantol, 24, pp.159~166 (1998)
  8. Piattelli A, "Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys", Int J Periodontics Restorative Dent, 17, pp.162~169 (1997)
  9. Piattelli A, "Microscopical observations of the osseous responses in early loaded human titanium implants: a report of two cases", Biomaterials, 17, pp.1333~1337 (1996)
  10. Lefkove MD, "Immediate loading of cylinder implants with overdentures in the mandibular symphysis: the titanium plasma- sprayed screw technique", J Oral Implantol, 16, pp.256~271 (1990)
  11. Misch CE, "Implant design considerations for the posterior regions of the mouth", Implant Dent, 8, pp.376~386 (1999)
  12. Hench LL, "Direct chemical bond of bioactive glassceramic materials to bone and muscle", J Biomed Mater Res, 7, pp.25~42 (1973)
  13. Ishizawa H, "Formation and characterization of anodic titanium oxide films containing Ca and P", J Biomed Mater Res, 29, pp.65~72 (1995)
  14. Sul YT, "Bone reactions to oxidized titanium implants with electrochemical anion sulphuric acid and phosphoric acid incorporation", Clin Implant Dent Relat Res, 4, pp.78~87 (2002)
  15. Sul YT, "Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone: effect of calcium surface chemistry of a novel implant", Clin Implant Dent Relat Res, 6, pp.101~110 (2004)
  16. Sul YT, "The bone response of oxidized bioactive and non-bioactive titanium implants", Biomaterials, 26, pp.6720~6730 (2005)
  17. Martin JY, "Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63)", J Biomed Mater Res, 29, pp.389~401 (1995)
  18. Zreiqat H, "Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants", J Biomed Mater Res, 62, pp.175~184 (2002)
  19. Lapidos KA, "Mg(++)-induced endothelial cell migration: substratum selectivity and receptor-involvement", Angiogenesis, 4, pp.21~28 (2001)
  20. Donath K, "Preparation of histologic sections by cutting-grinding technique for hard tissue and other materials not suitable to be sectioned by routine methods", pp.1~6 (1993), EXAKT-Kulzer-Publication
  21. Akagawa Y, "Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing", J Prosthet Dent, 69, pp.599~604 (1993)
  22. Sagara M, "The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study", J Prosthet Dent, 69, pp.281~288 (1993)
  23. Meredith N, "The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia", Clin Oral Implants Res, 8, pp.234~243 (1997)
  24. Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study", Int J Oral Maxillofac Surg, 28, pp.266~272 (1999)
  25. O’Sullivan D, "Measurements comparing the initial stability of five designs of dental implants: a human cadaver study", Clin Implant Dent Relat Res, 2, pp.85~92 (2000)
  26. Larsson C, "Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology", Biomaterials, 15, pp.1062~1074 (1994)
  27. de Lange GL, "Interface between bone tissue and implants of solid hydroxyapatite or hydroxyapatite-coated titanium implants", Biomaterials, 10, pp.121~125 (1989)
  28. Buser D, "Removal torque values of titanium implants in the maxilla of miniature pigs", Int J Oral Maxillofac Implants, 13, pp.611~619 (1998)
  29. Davies JE, "In vitro modeling of the bone", implant interface, 1996, pp.245, 426~445
  30. Wong M, "Effect of surface topology on the osseointegration of implant materials in trabecular bone", J Biomed Mater Res, 29, pp.1567~1575 (1995)
  31. Cochran DL, "The scientific basis for and clinical experiences with Straumann implants including the ITI Dental Implant System: a consensus report", Clin Oral Implants Res, 11, pp.33~58 (2000)
  32. Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs", J Biomed Mater Res, 25, pp.889~902 (1991)
  33. Larsson C, "Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology", Biomaterials, 15, pp.1062~1074 (1994)
  34. Chen G, "Corrosion resistance and ion dissolution of titanium with different surface microroughness", Biomed Mater Eng, 8, pp.61~74 (1998)
  35. McAlarney ME, "Effects of titanium dioxide passive film crystal structure, thickness, and crystallinity on C3 adsorption", Int J Oral Maxillofac Implants, 11, pp.73~80 (1996)
  36. Fujibayashi S, "Bioactive titanium: effect of sodium removal on the bone-bonding ability of bioactive titanium prepared by alkali and heat treatment", J Biomed Mater Res, 56, pp.562~570 (2001)
  37. Li J, "Behaviour of titanium and titania-based ceramics in vitro and in vivo", Biomaterials, 14, pp.229~232 (1993)

관련 논문AI추천

이 간행물의 다른 논문 (9건)