본문 바로가기
KERD
논문KCI 등재

Resorption of labial bone in maxillary anterior implant

2

조회

0

다운로드

5

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this study was to evaluate the amount of resorption and thickness of labial bone in anterior maxillary implant using cone beam computed tomography with Hitachi CB Mercuray (Hitachi, Medico, Tokyo, Japan). MATERIALS AND METHODS. Twenty-one patients with 26 implants were followed-up and checked with CBCT. 21 OSSEOTITE NT(R). (3i/implant Innovations, Florida, USA) and 5 OSSEOTITE(R). implants (3i/implant Innovations, Florida, USA) were placed at anterior region and they were positioned vertically at the same level of bony scallop of adjacent teeth. Whenever there was no lesion or labial bone was intact, immediate placement was tried as possible as it could be. Generated bone regeneration was done in the patients with the deficiency of hard tissue using Bio-Oss(R). (Geistlich, Wolhusen, Switzerland) and Bio-Gide(R). (Geistlich, Wolhusen, Switzerland). Second surgery was done in 6 months after implant placement and provisionalization was done for 3 months. Definite abutment was made of titanium abutment with porcelain, gold and zirconia, and was attached after provisionalization. Two-dimensional slices were created to produce sagittal, coronal, axial and 3D by using OnDemand3D (Cybermed, Seoul, Korea). RESULTS. The mean value of bone resorption (distance from top of implant to labial bone) was 1.32 ± 0.86 mm and the mean thickness of labial bone was 1.91 ± 0.45 mm. CONCLUSION. It is suggested that the thickness more than 1.91 mm could reduce the amount and incidence of resorption of labial bone in maxillary anterior implant.

Abstract

PURPOSE. The purpose of this study was to evaluate the amount of resorption and thickness of labial bone in anterior maxillary implant using cone beam computed tomography with Hitachi CB Mercuray (Hitachi, Medico, Tokyo, Japan). MATERIALS AND METHODS. Twenty-one patients with 26 implants were followed-up and checked with CBCT. 21 OSSEOTITE NT(R). (3i/implant Innovations, Florida, USA) and 5 OSSEOTITE(R). implants (3i/implant Innovations, Florida, USA) were placed at anterior region and they were positioned vertically at the same level of bony scallop of adjacent teeth. Whenever there was no lesion or labial bone was intact, immediate placement was tried as possible as it could be. Generated bone regeneration was done in the patients with the deficiency of hard tissue using Bio-Oss(R). (Geistlich, Wolhusen, Switzerland) and Bio-Gide(R). (Geistlich, Wolhusen, Switzerland). Second surgery was done in 6 months after implant placement and provisionalization was done for 3 months. Definite abutment was made of titanium abutment with porcelain, gold and zirconia, and was attached after provisionalization. Two-dimensional slices were created to produce sagittal, coronal, axial and 3D by using OnDemand3D (Cybermed, Seoul, Korea). RESULTS. The mean value of bone resorption (distance from top of implant to labial bone) was 1.32 ± 0.86 mm and the mean thickness of labial bone was 1.91 ± 0.45 mm. CONCLUSION. It is suggested that the thickness more than 1.91 mm could reduce the amount and incidence of resorption of labial bone in maxillary anterior implant.

참고문헌 (32)

  1. Garber DA, "The esthetic dental implant: letting restoration be the guide", J Oral Implantol, 22, pp.45~50 (1996)
  2. Tarnow DP, "Aesthetics and implant dentistry", Periodontol 2000, 11, pp.85~94 (1996)
  3. Becker W, "Guided tissue regeneration for implants placed into extraction sockets and for implant dehiscences: surgical techniques and case report", Int J Periodontics Restorative Dent, 10, pp.376~391 (1990)
  4. Bahat O, "Reconstruction of the hard and soft tissues for optimal placement of osseointegrated implants", Int J Periodontics Restorative Dent, 13, pp.255~275 (1993)
  5. Kan JY, "Site development for anterior single implant esthetics: the dentulous site", Compend Contin Educ Dent, 22, pp.221~226 (2001)
  6. Wo¨hrle PS, "Nobel Perfect esthetic scalloped implant: rationale for a new design", Clin Implant Dent Relat Res, 5, pp.64~73 (2003)
  7. Lazzara RJ, "Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels", Int J Periodontics Restorative Dent, 26, pp.9~17 (2006)
  8. Schrotenboer J, "Effect of microthreads and platform switching on crestal bone stress levels: a finite element analysis", J Periodontol, 79, pp.2166~2172 (2008)
  9. Lindquist LW, "A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss", Clin Oral Implants Res, 7, pp.329~336 (1996)
  10. Jung YC, "A 1-year radiographic evaluation of marginal bone around dental implants", Int J Oral Maxillofac Implants, 11, pp.811~818 (1996)
  11. Small PN, "Gingival recession around implants: a 1-year longitudinal prospective study", Int J Oral Maxillofac Implants, 15, pp.527~532 (2000)
  12. Bengazi F, "Recession of the soft tissue margin at oral implants. A 2-year longitudinal prospective study", Clin Oral Implants Res, 7, pp.303~310 (1996)
  13. Cecchinato D, "Bone level alterations at implants placed in the posterior segments of the dentition: outcome of submerged", non-submerged healing. A 5-year multicenter, randomized, controlled clinical trial, 2008, pp.19, 429~431
  14. Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  15. Oh TJ, "The causes of early implant bone loss: myth or science", J Periodontol, 73, pp.322~333 (2002)
  16. Hermann JS, "Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements", Int J Oral Maxillofac Implants, 16, pp.475~485 (2001)
  17. Persson LG, "Bacterial colonization on internal surfaces of Bra􀆆nemark system implant components", Clin Oral Implants Res, 7, pp.90~95 (1996)
  18. Guindy JS, "Bacterial leakage into and from prefabricated screw-retained implant-borne crowns in vitro", J Oral Rehabil, 25, pp.403~408 (1998)
  19. Broggini N, "Persistent acute inflammation at the implant-abutment interface", J Dent Res, 82, pp.232~237 (2003)
  20. Cochran DL, "Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible", J Periodontol, 68, pp.186~198 (1997)
  21. Hermann JS, "Biologic width around titanium implants. A physiologically formed and stable dimension over time", Clin Oral Implants Res, 11, pp.1~11 (2000)
  22. Hermann JS, "Biologic Width around one- and two-piece titanium implants", Clin Oral Implants Res, 12, pp.559~571 (2001)
  23. Abrahamsson I, "The mucosal barrier following abutment dis", reconnection. An experimental study in dogs, 1997, pp.24, 568~572
  24. Benkow HH, "A new principle and appliance for radiographic tooth measurements", J Dent Res, 36, pp.641~643 (1957)
  25. Rosling B, "A radiographic method for assessing changes in alveolar bone height following periodontal therapy", J Clin Periodontol, 2, pp.211~217 (1975)
  26. Scarfe WC, "Clinical applications of conebeam computed tomography in dental practice", J Can Dent Assoc, 72, pp.75~80 (2006)
  27. Draenert FG, "Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT", Dentomaxillofac Radiol, 36, pp.198~203 (2007)
  28. Davarpanah M, "A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data", Int J Oral Maxillofac Implants, 17, pp.820~828 (2002)
  29. Levin L, "Aesthetic versus surgical success of single dental implants: 1- to 9-year follow-up", Pract Proced Aesthet Dent, 17, pp.535~538 (2005)
  30. Esposito M, "Radiological evaluation of marginal bone loss at tooth surfaces facing single Bra􀆆nemark implants", Clin Oral Implants Res, 4, pp.151~157 (1993)
  31. Ha¨nggi MP, "Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths", J Periodontol, 76, pp.791~802 (2005)
  32. Spray JR, "The influence of bone thickness on facial marginal bone response: stage 1 placement through stage 2 uncovering", Ann Periodontol, 5, pp.119~128 (2000)

관련 논문AI추천

Cone-beam computed tomographic analysis of the alveolar ridge profile and virtual implant placement for the anterior maxilla허익, 강도욱, 백혜현, 신승윤, 신승일, 임현창, 정종혁, 홍지연대한치주과학회 · Journal of Periodontal & Implant Science2019 · 제49권 제5호Horizontal alteration of anterior alveolar ridge after immediate implant placement: A retrospective cone beam computed tomography analysis류재준, 송소연, 심지석, Chung Yun Lee, Selvaponpriya Ramasamy, Subramanian Keerthana, Young Keun Hyun대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호전산화 단층 촬영을 이용한 상악 전치부 자연치의 순측과 구개측 골의 두께 계측김종관, 김창성, 박정철, 배수용, 손주연, 엄유정, 정의원, 조규성, 채중규, 최성호대한치과의사협회 · 대한치과의사협회지2009 · 제47권 제10호Assessment of buccal bone thickness of aesthetic maxillary region: a conebeam computed tomography studyCarlos Salamanca, Eduardo Borie, Pablo Navarro, Ramón Fuentes, Tania Flores, Víctor Beltrán대한치주과학회 · Journal of Periodontal & Implant Science2015 · 제45권 제5호Angulation between Long Axis of Anterior Teeth and Alveolar Process, and Thickness of Alveolar Bone김석, 김흥중, 김희주, 유선경, 이명화대한체질인류학회 · 해부·생물인류학2012 · 제25권 제1호Labial and lingual/palatal bone thickness of maxillary and mandibular anteriors in human cadavers in Koreans정겨운, 한지영대한치주과학회 · Journal of Periodontal & Implant Science2011 · 제41권 제2호

이 간행물의 다른 논문 (9건)