본문 바로가기
KERD
논문KCI 등재

Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. Materials and methods. Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. Results. The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). Conclusion. Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.

Abstract

Purpose. This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements. Materials and methods. Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05. Results. The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05). Conclusion. Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.

관련 논문AI추천

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis경문수, 김시현, 박규남, 오재섭한국전문물리치료학회 · 한국전문물리치료학회지2019 · 제26권 제3호초음파식 디지털 pantograph의 임상적 유의성과 활용강동완, 김민주, 손미경, 이경제, 이진영치의학연구원 · Oral Biology Research2013 · 제37권 제1호A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking deviceFei Liu, Jiansong Mei, Jiarui Chao, Jiefei Shen, Liya Ma, Zhenyu Wang대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제1호JT-3D system을 이용한 하악의 운동 분석김려운, 김희중, 변재준, 송주헌, 이경제, 허유리대한턱관절교합학회 · 구강회복응용과학지2020 · 제36권 제2호Impact of digital jaw tracking systems on dynamic occlusal surface morphology and condylar inclination measurementsAlper Aktosun, Ayşenur Özcan-Sezgin, Berk Bilgen, Sina Saygılı, Tonguç Sülün대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제4호The influence of horizontal cephalic rotation on the deviation of mandibular positionFumi Mizuhashi, Kaoru Koide, Katsuyoshi Koide, Naoto Katayama대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제6호

이 간행물의 다른 논문 (4건)