Detection of Allergen Specific IgE by AdvanSure Allergy Screen Test
2
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Background : In vitro serum allergen-specific IgE tests have been routinely used in the clinical diagnosis of allergic diseases. We evaluated the clinical usefulness of a newly introduced multiple antigen screen test, Advansure Allergy Screen (LG Life Science, Korea) (LG-Screen) for the detection of allergen specific IgE. Methods : A total of 180 sera (80 for inhalant and 100 for food panels) were tested by LG-Screen and RIDA Allergy Screen (R-biopharm, Germany) (RIDA-Screen) assays. According to the 58-60 specific allergens or allergen groups, the positive rates and agreement rates were analyzed using the cut off levels of class 2. For the quantitation of total IgE and specific IgE, nephelometry and ImmunoCAP test were performed in the sera showing discrepant results between the two allergy screen assays. Results : The agreement rate and kappa value (k) of total IgE between the two allergy screen assays was 73.9% and 0.333. LG-Screen showed higher agreement rate with nephelometry than RIDA-Screen. The positive rates to common outdoor inhalant and food allergens were significantly higher in RIDA-Screen. Overall agreement rate of specific IgE between the two allergy screen assays for 58 allergens was 86.7% (6,086/7,020) (k, 0.293). In samples showing discrepant results between the two allergy screen assays, concordance rate of allergy screen assay with ImmunoCAP assay was 70.9% (449/633) for LG-Screen (k, 0.585) and 29.1% (184/633) for RIDA-Screen (k, -0.303). Conclusions : LG-Screen showed a favorable agreement with RIDA-Screen and ImmunoCAP assays, and it could be used for the detection of allergen specific IgE in the clinical laboratory. (Korean J Lab Med 2010;30:420-31)
Abstract
Background : In vitro serum allergen-specific IgE tests have been routinely used in the clinical diagnosis of allergic diseases. We evaluated the clinical usefulness of a newly introduced multiple antigen screen test, Advansure Allergy Screen (LG Life Science, Korea) (LG-Screen) for the detection of allergen specific IgE. Methods : A total of 180 sera (80 for inhalant and 100 for food panels) were tested by LG-Screen and RIDA Allergy Screen (R-biopharm, Germany) (RIDA-Screen) assays. According to the 58-60 specific allergens or allergen groups, the positive rates and agreement rates were analyzed using the cut off levels of class 2. For the quantitation of total IgE and specific IgE, nephelometry and ImmunoCAP test were performed in the sera showing discrepant results between the two allergy screen assays. Results : The agreement rate and kappa value (k) of total IgE between the two allergy screen assays was 73.9% and 0.333. LG-Screen showed higher agreement rate with nephelometry than RIDA-Screen. The positive rates to common outdoor inhalant and food allergens were significantly higher in RIDA-Screen. Overall agreement rate of specific IgE between the two allergy screen assays for 58 allergens was 86.7% (6,086/7,020) (k, 0.293). In samples showing discrepant results between the two allergy screen assays, concordance rate of allergy screen assay with ImmunoCAP assay was 70.9% (449/633) for LG-Screen (k, 0.585) and 29.1% (184/633) for RIDA-Screen (k, -0.303). Conclusions : LG-Screen showed a favorable agreement with RIDA-Screen and ImmunoCAP assays, and it could be used for the detection of allergen specific IgE in the clinical laboratory. (Korean J Lab Med 2010;30:420-31)
참고문헌 (20)
- Hamilton RG, "Clinical laboratory assessment of immediate-type hypersensitivity", J Allergy Clin Immunol, 125, pp.S284~S296 (2010)
- Cox L, "Pearls and pitfalls of allergy diagnostic testing: report from the American College of Allergy, Asthma and Immunology", American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force, 2008, pp.101, 580~592
- Steckelbroeck S, "Potential, pitfalls, and prospects of food allergy diagnostics with recombinant allergens or synthetic sequential epitopes", J Allergy Clin Immunol, 121, pp.1323~1330 (2008)
- 임환섭, "국내 혈청 알레르기 항원 검사법의 현황", The Korean Journal of Laboratory Medicine, 28(2), pp.124~129 (2008), 대한진단검사의학회
- CLSI, "Analytical performance characteristics and clinical utility of immunological assays for human immunoglobulin E (IgE) antibodies and defined allergen specificities: approved guideline. CLSI document I", LA20-A2. 2nd ed, 2009
- 박도심, "Multiple Antigen Simultaneous Test-Immunoblot법을 이용한 알러젠 특이항체 검출", The Korean Journal of Laboratory Medicine, 24(2), pp.131~138 (2004), 대한진단검사의학회
- 장우리, "Polycheck Allergy를 이용한 알레르겐 특이 IgE 측정: 세 가지 다중 알레르겐 항원 검사법의 비교", The Korean Journal of Laboratory Medicine, 29(5), pp.465~472 (2009), 대한진단검사의학회
- 박창한, "알레르기 환자에서 한국의 대표적 흡입성 항원 16종의 특이 IgE 측정: GENEDIA-ELISA (Genedia Inhalant Allergen ELISA?)법과 MAST-Immunoblot (RIDASCREEN?)법 결과 비교", 천식 및 알레르기, 27(1), pp.26~32 (2007), 대한천식알레르기학회
- 김태범, "흡입 알레르겐에 대한 감작율: 다기관 공동연구", 천식 및 알레르기, 23(3), pp.483~493 (2003), 대한천식알레르기학회
- 김규언, "소아 천식환자에서 식품알레르기의 빈도 및 원인 식품", 소아알레르기및호흡기학회지, 5, pp.96~106 (1995)
- Williams P, "Clinical immunology review series: an approach to the use of the immunology laboratory in the diagnosis of clinical allergy", Clin Exp Immunol, 153, pp.10~18 (2008)
- Gendo K, "Evidence-based diagnostic strategies for evaluating suspected allergic rhinitis", Ann Intern Med, 140, pp.278~289 (2004)
- Sampson HA, "Relationship between food-specific IgE concentrations and the risk of positive food challenges in children and adolescents", J Allergy Clin Immunol, 100, pp.444~451 (1997)
- 오재원, "피부단자시험을 기준으로 한 시험관내 집먼지진드기와식품 알레르겐 특이 IgE 항체 측정 방법의 효용성 비교", 대한소아알레르기및호흡기학회지, 13(2), pp.72~80 (2003), 대한 소아알레르기 호흡기학회
- Ricci G, "A comparison of different allergometric tests, skin prick test, Pharmacia UniCAP and ADVIA Centaur, for diagnosis of allergic diseases in children", Allergy, 58, pp.38~45 (2003)
- Williams PB, "Analytic precision and accuracy of commercial immunoassays for specific IgE:establishing a standard", J Allergy Clin Immunol, 105, pp.1221~1230 (2000)
- Feinstein AR, "High agreement but low kappa: I. The problems of two paradoxes", J Clin Epidemiol, 43, pp.543~549 (1990)
- Ahlstedt S, "In vitro diagnosis of allergy: how to interpret IgE antibody results in clinical practice", Prim Care Respir J, 15, pp.228~236 (2006)
- Jenkins JA, "Structural relatedness of plant food allergens with specific reference to cross-reactive allergens: an in silico analysis", J Allergy Clin Immunol, 115, pp.163~170 (2005)
- Weber RW, "Patterns of pollen cross-allergenicity", J Allergy Clin Immunol, 112, pp.229~239 (2003)
