본문 바로가기
KERD
논문KCI 등재

Quantification of Human Plasma-Busulfan Concentration by Liquid Chromatography-Tandem Mass Spectrometry

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Busulfan, an alkylating agent administered prior to hematopoietic stem cell transplantation, has a narrow therapeutic range and wide variability in metabolism. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for rapid and accurate quantification of plasma busulfan. Methods: Busulfan was separated and detected using an LC system containing a C18 column equipped with MS/MS. The sample was eluted with a mobile phase gradient for a total run time of 10 min. Plasma busulfan concentration was quantified against a 6-point standard curve in a multiple reaction monitoring mode at mass-to-charge ( m/z ) 264.1 > 151.1. Precision, recovery, matrix effect, linearity, detection capability, carryover, and sta- bility were evaluated. The range of plasma busulfan concentration was obtained by ana- lyzing samples from 9 children receiving busulfan. Results: The coefficients of variation of within-run and within-laboratory precision were all below 5%. Recoveries were all within the range of 100-105%. Linearity was verified from 0 to 5,000 ng/mL. Limit of detection and limit of quantification were 1.56 and 25 ng/mL, respectively. Carryover rate was within allowable limits. Plasma busulfan concentration was stable for 2 weeks at -20°C and -80°C, but decreased by 25% when the plasma was stored for 24 hr at room temperature, and by <5% in 24 hr at 4°C. The plasma busulfan concentrations were between 347 ng/mL and 5,076 ng/mL. Conclusions: Our method using LC-MS/MS enables highly accurate, reproducible, and rapid busulfan monitoring with minimal sample preparation. The method may also enable safe and proper dosage.

Abstract

Background: Busulfan, an alkylating agent administered prior to hematopoietic stem cell transplantation, has a narrow therapeutic range and wide variability in metabolism. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for rapid and accurate quantification of plasma busulfan. Methods: Busulfan was separated and detected using an LC system containing a C18 column equipped with MS/MS. The sample was eluted with a mobile phase gradient for a total run time of 10 min. Plasma busulfan concentration was quantified against a 6-point standard curve in a multiple reaction monitoring mode at mass-to-charge ( m/z ) 264.1 > 151.1. Precision, recovery, matrix effect, linearity, detection capability, carryover, and sta- bility were evaluated. The range of plasma busulfan concentration was obtained by ana- lyzing samples from 9 children receiving busulfan. Results: The coefficients of variation of within-run and within-laboratory precision were all below 5%. Recoveries were all within the range of 100-105%. Linearity was verified from 0 to 5,000 ng/mL. Limit of detection and limit of quantification were 1.56 and 25 ng/mL, respectively. Carryover rate was within allowable limits. Plasma busulfan concentration was stable for 2 weeks at -20°C and -80°C, but decreased by 25% when the plasma was stored for 24 hr at room temperature, and by <5% in 24 hr at 4°C. The plasma busulfan concentrations were between 347 ng/mL and 5,076 ng/mL. Conclusions: Our method using LC-MS/MS enables highly accurate, reproducible, and rapid busulfan monitoring with minimal sample preparation. The method may also enable safe and proper dosage.

참고문헌 (31)

  1. Nath CE, "Busulphan in blood and marrow transplantation: dose, route, frequency and role of therapeutic drug monitoring", Curr Clin Pharmacol, 2, pp.75~91 (2007)
  2. Ciurea SO, "Busulfan in hematopoietic stem cell transplantation", Biol Blood Marrow Transplant, 15, pp.523~536 (2009)
  3. Russell JA, "Therapeutic drug monitoring of busulfan in transplantation", Curr Pharm Des, 14, pp.1936~1949 (2008)
  4. Dean RM, "Superior survival after replacing oral with intravenous busulfan in autologous stem cell transplantation for non-Hodgkin lymphoma with busulfan, cyclophosphamide and etoposide", Br J Haematol, 148, pp.226~234 (2010)
  5. Lee JW, "Highly variable pharmacokinetics of once-daily intravenous busulfan when combined with fludarabine in pediatric patients: phase I clinical study for determination of optimal once-daily busulfan dose using pharmacokinetic modeling", Biol Blood Marrow Transplant, 18, pp.944~950 (2012)
  6. Gaziev J, "Novel pharmacokinetic behavior of intravenous busulfan in children with thalassemia undergoing hematopoietic stem cell transplantation: a prospective evaluation of pharmacokinetic and pharmacodynamic profile with therapeutic drug monitoring", Blood, 115, pp.4597~4604 (2010)
  7. Paci A, "Pharmacokinetic behavior and appraisal of intravenous busulfan dosing in infants and older children: the results of a population pharmacokinetic study from a large pediatric cohort undergoing hematopoietic stem-cell transplantation", Ther Drug Monit, 34, pp.198~208 (2012)
  8. Méresse V, "Risk factors for hepatic veno-occlusive disease after high-dose busulfan-containing regimens followed by autologous bone marrow transplantation: a study in 136 children", Bone Marrow Transplant, 10, pp.135~141 (1992)
  9. Carreras E, "Veno-occlusive disease of the liver after high-dose cytoreductive therapy with busulfan and melphalan for autologous blood stem cell transplantation in multiple myeloma patients", Biol Blood Marrow Transplant, 13, pp.1448~1454 (2007)
  10. Chen TL, "Determination of busulfan in human plasma by gas chromatography with electron-capture detection", J Chromatogr, 425, pp.303~309 (1988)
  11. Quernin MH, "Quantification of busulfan in plasma by gas chromatography-mass spectrometry following derivatization with tetrafluorothiophenol", J Chromatogr B Biomed Sci Appl, 709, pp.47~56 (1998)
  12. Bleyzac N, "Rapid and sensitive high-performance liquid chromatographic method for busulfan assay in plasma", J Chromatogr B Biomed Sci Appl, 742, pp.427~432 (2000)
  13. Peris JE, "Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection", J Chromatogr B Biomed Sci Appl, 730, pp.33~40 (1999)
  14. Courtney JB, "Determination of busulfan in human plasma using an ELISA format", Ther Drug Monit, 31, pp.489~494 (2009)
  15. Mürdter TE, "Sensitive and rapid quantification of busulfan in small plasma volumes by liquid chromatography-electrospray mass spectrometry", Clin Chem, 47, pp.1437~1442 (2001)
  16. Quernin MH, "Quantification of busulfan in plasma by liquid chromatography-ion spray mass spectrometry. Application to pharmacokinetic studies in children", J Chromatogr B Biomed Sci Appl, 763, pp.61~69 (2001)
  17. Kellogg MD, "Tandem mass spectrometry method for the quantification of serum busulfan", Ther Drug Monit, 27, pp.625~629 (2005)
  18. dos Reis EO, "Development of a rapid and specific assay for detection of busulfan in human plasma by high-performance liquid chromatography", electrospray ionization tandem mass spectrometry, 2005, pp.19, 1666~1674
  19. Bunch DR, "A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology", J Chromatogr B Analyt Technol Biomed Life Sci, 878, pp.3255~3258 (2010)
  20. Ansari M, "A simplified method for busulfan monitoring using dried blood spot in combination with liquid chromatography", tandem mass spectrometry, 2012, pp.26, 1437~1446
  21. Food and Drug Administration, "Guidance for Industry: Bioanalytical method validation", U.S. Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, ~ (2001)
  22. Clinical and Laboraotry Standards Institute, "User verification of performance for precision and trueness; Approved guideline", Clinical and Laboraotry Standards Institute, ~ (2005)
  23. Matuszewski BK, "Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS", MS, 2003, pp.75, 3019~3030
  24. NCCLS, "Evaluation of the linearity of quantitative measurement procedures: a statistical approach; approved guideline", National Committee for Clinical Laboratory Standards, ~ (2003)
  25. International Conference on Harmonization, "Q2B: validation of analytical procedures: methodology", US FDA Federal Register, 62, pp.27463~27467 (1997)
  26. 이현지, "Elecsys Hepatitis B Surface Antigen Quantitative Assay: Performance Evaluation and Correlation with Hepatitis B Virus DNA during 96 Weeks of Follow-up in Chronic Hepatitis B Patients", Annals of Laboratory Medicine, 32(6), pp.420~425 (2012), 대한진단검사의학회
  27. Snyder ML, "Quantification of busulfan in plasma using liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS", MS), 2010, pp.603, 129~136
  28. Oechtering D, "Monitoring of N,N-dimethylacetamide in children during i.v.-busulfan therapy by liquid chromatography-mass spectrometry", J Chromatogr B Analyt Technol Biomed Life Sci, 838, pp.129~134 (2006)
  29. Hempel G, "Cytotoxicity of dimethylacetamide and pharmacokinetics in children receiving intravenous busulfan", J Clin Oncol, 25, pp.1772~1778 (2007)
  30. Cooper AJ, "Metabolism of the cysteine S-conjugate of busulfan involves a beta-lyase reaction", Drug Metab Dispos, 36, pp.1546~1552 (2008)
  31. Versace F, "A novel method for quantification of sulfolane (a metabolite of busulfan) in plasma by gas chromatography-tandem mass spectrometry", Anal Bioanal Chem, 404, pp.1831~1838 (2012)

관련 논문AI추천

Evaluation of Stability of Thiopurine Metabolites Using a Validated LC-MS/MS Method우혜인, 유인영, 이경훈, 이수연, 지옥자대한진단검사의학회 · Annals of Laboratory Medicine2018 · 제38권 제3호Quantification of Thioguanine in DNA Using Liquid Chromatography-Tandem Mass Spectrometry for Routine Thiopurine Drug Monitoring in Patients With Pediatric Acute Lymphoblastic Leukemia이수연, 이지원, Cho Hee Won, Choi Rihwa, Chun Mi Ryung, Hyun Ju Kyung, Ju Hee Young, Koo Hong Hoe, Park Jisook, Yi Eun Sang대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제2호조혈모세포 이식을 받은 소아 환자에서 cyclosporine의 집단 약동학 분석이정, 강원구, 곽혜선, 김재연, 안숙희, 조소연한국임상약학회 · 한국임상약학회지2018 · 제28권 제1호소아 골수이식 환자에서 Cyclosporine의 약동학적 변수 도출박경호, 손인자, 오정미, 윤경아, 이용화, 조영환한국병원약사회 · 병원약사회지2007 · 제24권 제1호Development and validation of a selective and sensitive LC-MS/MS method for determination of misoprostol acid in human plasma: Application to bioequivalence studyHeon Soo Lee, Jin Young Kim, Jung Hwan Kim, Keun Nam Kim, Soo Ji Sim, Ye Na Kim, Yong Sun Park한국분석과학회 · 분석과학2015 · 제28권 제1호Immunosuppressive Drug Measurement by Liquid Chromatography Coupled to Tandem Mass Spectrometry: Interlaboratory Comparison in the Korean Clinical LaboratoriesAhn Sunhyun, Chae Hyojin, Chun Sail, Kim Hyun-Ki, Kim Serim, Lee Sang-Guk, Lee Soo-Youn, Lee Sun Min, Lee Yong-Wha, Park Hyung-Doo, Song Sang Hoon, Yun Yeo-Min대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제3호

이 간행물의 다른 논문 (16건)