Immunosuppressive Drug Measurement by Liquid Chromatography Coupled to Tandem Mass Spectrometry: Interlaboratory Comparison in the Korean Clinical Laboratories
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Background: Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories. This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. Methods: Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. Results: The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ=0.334, P=0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P=0.015 for 14 days; P=0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. Conclusions: LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.
Abstract
Background: Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is increasingly used for immunosuppressive drug tests. However, most LC-MS/MS tests are laboratory-developed and their agreement is unknown in different Korean laboratories. This interlaboratory comparison study evaluated test reproducibility and identified potential error sources. Methods: Test samples containing three concentrations of tacrolimus, sirolimus, everolimus, cyclosporine, and mycophenolic acid were prepared by pooling surplus samples from patients undergoing routine therapeutic drug monitoring and tested in duplicate in the participating 10 clinical laboratories. Reconstitution and storage experiments were conducted for the commonly used commercial calibrator set. The robust estimators of reproducibility parameters were calculated. Spearman’s rank correlation coefficient (rho, ρ) was used to evaluate the correlation between drugs. Multiple linear regression was used to determine whether the experimental conditions alter the calibration curves. Results: The reproducibility coefficient of variation exceeded 10% only for sirolimus concentrations 1 and 2 (10.8% and 12.5%, respectively) and everolimus concentrations 1 and 2 (12.3% and 11.4%, respectively). The percent difference values showed weak correlations between sirolimus and everolimus (ρ=0.334, P=0.175). The everolimus calibration curve slope was significantly altered after reconstitution following prolonged 5°C storage (P=0.015 for 14 days; P=0.025 for 28 days); the expected differences at 6 ng/mL were 0.598% for 14 days and 0.384% for 28 days. Conclusions: LC-MS/MS test reproducibility for immunosuppressive drugs seems to be good in the Korean clinical laboratories. Continuous efforts are required to achieve test standardization and harmonization, especially for sirolimus and everolimus.
참고문헌 (27)
- McShane AJ, "Therapeutic drug monitoring of immunosuppressants by liquid chromatography-mass spectrometry", Clin Chim Acta, 454, pp.1~5 (2016)
- Zhang Y, "Recent advances in analytical methods for the therapeutic drug monitoring of immunosuppressive drugs", Drug Test Anal, 10, pp.81~94 (2018)
- Khan S, "Immunosuppressive drug therapy–biopharmaceutical challenges and remedies", Expert Opin Drug Deliv, 12, pp.1333~1349 (2015)
- Mohammadpour N, "A review on therapeutic drug monitoring of immunosuppressant drugs", Iran J Basic Med Sci, 14, pp.485~498 (2011)
- Bentata Y, "Mycophenolates: the latest modern and potent immunosuppressive drugs in adult kidney transplantation: what we should know about them?", Artif Organs, 44, pp.561~576 (2020)
- Kuypers DR, "Consensus report on therapeutic drug monitoring of mycophenolic acid in solid organ transplantation", Clin J Am Soc Nephrol, 5, pp.341~358 (2010)
- Annesley TM, "Standardization of LC-MS for therapeutic drug monitoring of tacrolimus", Clin Chem, 59, pp.1630~1637 (2013)
- Immunosuppressive drugs. CSM-A 2018; participant summary, "CAP", College of American Pathologists, ~ (2018)
- Immunosuppressants therapeutic drug monitoring 2018; summary report, "KEQAS", Korean Association of External Quality Assessment Service, ~ (2018)
- Berlinger B, "Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples", J Occup Environ Hyg, 15, pp.152~156 (2018)
- Christians U, "Impact of laboratory practices on interlaboratory variability in therapeutic drug monitoring of immunosuppressive drugs", Ther Drug Monit, 37, pp.718~724 (2015)
- Pitkälä A, "Interlaboratory proficiency testing as a tool for improving performance in laboratories diagnosing bovine mastitis", J Dairy Sci, 88, pp.553~559 (2005)
- 정태동, "Accuracy-Based Proficiency Testing of Creatinine Measurement: 7 Years’ Experience in Korea", Laboratory Medicine and Quality Assurance, 41(1), pp.13~23 (2019), 대한진단검사정도관리협회[DOI]
- 채효진, "Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey", Annals of Laboratory Medicine, 39(5), pp.447~453 (2019), 대한진단검사의학회[DOI]
- Volodarsky ET, "Robust algorithm S to assess the precision of interlaboratory measurements", Meas Autom Monit, 61, pp.111~114 (2015)
- ISO, "Statistical methods for use in proficiency testing by interlaboratory comparison", ISO 13528:2015, International Organization for Standardization, ~ (2015)
- Honour JW, "Development and validation of a quantitative assay based on tandem mass spectrometry", Ann Clin Biochem, 48, pp.97~111 (2011)
- Everolimus. EV-A 2018; participant summary, "CAP", College of American Pathologists, ~ (2018)
- Everolimus. EV-B 2018; participant summary, "CAP", College of American Pathologists, ~ (2018)
- Immunosuppressive drugs. CSM-B 2018; participant summary, "CAP", College of American Pathologists, ~ (2018)
- Chromsystems, "6PLUS1 multilevel calibrator set, immunosuppressants. 28039" (2018), Chromsystems Instruments and Chemicals GmbH
- Carter GD, "Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D", Ann Clin Biochem, 46, pp.79~81 (2009)
- Levine DM, "The need for standardization of tacrolimus assays", Clin Chem, 57, pp.1739~1747 (2011)
- Valbuena H, "Comparing the effect of isotopically labeled or structural analog internal standards on the performance of a LC-MS", MS method to determine ciclosporin A, everolimus, sirolimus and tacrolimus in whole blood, 2016, pp.54, 437~446
- Zhao Y, "Reasons for calibration standard curve slope variation in LC-MS assays and how to address it", Bioanalysis, 6, pp.1439~1443 (2014)
- Schniedewind B, "Long-term performance of laboratory-developed liquid chromatography-tandem mass spectrometry tests and a Food and Drug Administration-approved immunoassay for the therapeutic drug monitoring of everolimus", Ther Drug Monit, 42, pp.421~426 (2020)
- Wong SK, "Performance evaluation for proficiency testing with a limited number of participants", Accred Qual Assur, 16, pp.539~ (2011)
