초록

Intermediate-resolution HLA-DQ typing has gained importance in organ transplantation recently. We evaluated the performance of the LIFECODES HLA-DQB1 typing kit (Immucor, USA) using sequence-specific oligonucleotide (SSO) probe and Luminex platform (Luminex Corp., USA) on 100 samples tested by sequence-based typing (SBT) using the AlleleSEQR HLA-DQB1 kit (Abbott Molecular, USA) in Korean individuals. No sample showed ambiguity in the assignment of 4-digit HLA-DQB1 allele with the LIFECODES HLA-DQB1 SSO typing kit, and the results were fully concordant with those of high-resolution typing of AlleleSEQR HLA-DQB1 SBT up to 4-digit level. Three samples required adjustment of false reactions (3/100, 3.0%): two samples with DQB1*03:03/*06:01 showed false-positive result in probe 253, and 1 sample with DQB1*04:02/*05:02 showed false-negative result in probe 217. We tested an additional sample with DQB1*03:03/*06:01, which showed same false-positivity in probe 253 and 2 samples with DQB1*04:02/*05:02, which showed no false reaction. The false reactions did not result in ambiguity or change in the HLA allele assignment. We could assign HLA-DQB1 alleles to 4 digit-level without ambiguity, with 100% concordance with the SBT results. Thus, LIFECODES HLA-DQB1 SSO typing kit showed good performance for intermediate-resolution HLA-DQB1 typing in clinical laboratory for organ transplantation in Koreans.

Abstract

Intermediate-resolution HLA-DQ typing has gained importance in organ transplantation recently. We evaluated the performance of the LIFECODES HLA-DQB1 typing kit (Immucor, USA) using sequence-specific oligonucleotide (SSO) probe and Luminex platform (Luminex Corp., USA) on 100 samples tested by sequence-based typing (SBT) using the AlleleSEQR HLA-DQB1 kit (Abbott Molecular, USA) in Korean individuals. No sample showed ambiguity in the assignment of 4-digit HLA-DQB1 allele with the LIFECODES HLA-DQB1 SSO typing kit, and the results were fully concordant with those of high-resolution typing of AlleleSEQR HLA-DQB1 SBT up to 4-digit level. Three samples required adjustment of false reactions (3/100, 3.0%): two samples with DQB1*03:03/*06:01 showed false-positive result in probe 253, and 1 sample with DQB1*04:02/*05:02 showed false-negative result in probe 217. We tested an additional sample with DQB1*03:03/*06:01, which showed same false-positivity in probe 253 and 2 samples with DQB1*04:02/*05:02, which showed no false reaction. The false reactions did not result in ambiguity or change in the HLA allele assignment. We could assign HLA-DQB1 alleles to 4 digit-level without ambiguity, with 100% concordance with the SBT results. Thus, LIFECODES HLA-DQB1 SSO typing kit showed good performance for intermediate-resolution HLA-DQB1 typing in clinical laboratory for organ transplantation in Koreans.

참고문헌 (12)

  1. Tambur AR, "Epitope analysis of HLA-DQ antigens: what does the antibody see?", Transplantation, 98, pp.157~166 (2014)
  2. Lachmann N, "Luminex® and its applications for solid organ transplantation, hematopoietic stem cell transplantation, and transfusion", Transfus Med Hemother, 40, pp.182~189 (2013)
  3. Trajanoski D, "HLA typing using bead-based methods", Methods Mol Biol, 882, pp.47~65 (2012)
  4. Testi M, "Evaluation of DRB1 high resolution typing by a new SSO-based Luminex method", Mol Biol Rep, 39, pp.13~16 (2012)
  5. Song EY, "HLA class II allele and haplotype frequencies in Koreans based on 107 families", Tissue Antigens, 59, pp.475~486 (2002)
  6. Roh EY, "Association of HLA-DR and -DQ genes with narcolepsy in Koreans: comparison with two control groups, randomly selected subjects and DRB1*1501-DQB1*0602--positive subjects", Hum Immunol, 67, pp.749~755 (2006)
  7. DeVos JM, "Donor-specific HLA-DQ antibodies may contribute to poor graft outcome after renal transplantation", Kidney Int, 82, pp.598~604 (2012)
  8. Willicombe M, "De novo DQ donor-specific antibodies are associated with a significant risk of antibody-mediated rejection and transplant glomerulopathy", Transplantation, 94, pp.172~177 (2012)
  9. Tambur AR, "The complexity of human leukocyte antigen (HLA)-DQ antibodies and its effect on virtual crossmatching", Transplantation, 90, pp.1117~1124 (2010)
  10. Claas FH, "Enhanced kidney allocation to highly sensitized patients by the acceptable mismatch program", Transplantation, 88, pp.447~452 (2009)
  11. Saito S, "Allele frequencies and haplotypic associations defined by allelic DNA typing at HLA class I and class II loci in the Japanese population", Tissue Antigens, 56, pp.522~529 (2000)
  12. Rossman MD, "HLA-DRB1*1101: a significant risk factor for sarcoidosis in blacks and whites", Am J Hum Genet, 73, pp.720~735 (2003)

관련 논문AI추천

Resolution of Ambiguous HLA Genotyping in Korean by Multi-Group-Specific Sequence-Based Typing권오중, 김유선, 김현숙, 박용정, 윤차은연세대학교의과대학 · Yonsei Medical Journal2014 · 제55권 제4호Allele and Haplotype Frequencies of Human Leukocyte Antigen-A, -B, -C, -DRB1, and -DQB1 From Sequence-Based DNA Typing Data in Koreans신수, 노은연, 박경운, 송은영, 오소희, 인지원대한진단검사의학회 · Annals of Laboratory Medicine2015 · 제35권 제4호Dynal RELITM SSO HLA-DRB Test 키트를 이용한 HLA-DR 형별 검사의 Ambiguity 분석 및 한국형 해석 프로그램의 개발김병철, 김선미, 박명희, 박성근, 송은영, 임영미, 한복연대한진단검사의학회 · Annals of Laboratory Medicine2002 · 제22권 제4호Allele Frequency Analysis of HLA-A, -B, -DRB1, -DQA1, and -DQB1 Using LABTypeTM SSO in a Patient Cohort from Jeonbuk National University HospitalMUN Ji Young, PARK Joonhong대한임상검사과학회 · 대한임상검사과학회지2025 · 제57권 제3호Identification of 8-Digit HLA-A, -B, -C, and -DRB1 Allele and Haplotype Frequencies in Koreans Using the One Lambda AllType Next-Generation Sequencing KitChae Jeong-Don, Choe Wonho, Choi Sung-Eun, Hwang Sang-Hyun, Oh Heung-Bum, Yang John Jeongseok대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제3호Human Leukocyte Antigen 검사 신빙도조사 결과(2005-2006년)김명희, 오흥범, 최성은대한진단검사의학회 · Annals of Laboratory Medicine2007 · 제27권 제6호

이 간행물의 다른 논문 (35건)