Evaluation of VITEK Mass Spectrometry (MS), a Matrix-Assisted Laser Desorption Ionization Time-of-Flight MS System for Identification of Anaerobic Bacteria
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background: By conventional methods, the identification of anaerobic bacteria is more time consuming and requires more expertise than the identification of aerobic bacteria. Although the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems are relatively less studied, they have been reported to be a promising method for the identification of anaerobes. We evaluated the performance of the VITEK MS in vitro diagnostic (IVD; 1.1 database; bioMérieux, France) in the identification of anaerobes. Methods: We used 274 anaerobic bacteria isolated from various clinical specimens. The results for the identification of the bacteria by VITEK MS were compared to those obtained by phenotypic methods and 16S rRNA gene sequencing. Results: Among the 249 isolates included in the IVD database, the VITEK MS correctly identified 209 (83.9%) isolates to the species level and an additional 18 (7.2%) at the genus level. In particular, the VITEK MS correctly identified clinically relevant and frequently isolated anaerobic bacteria to the species level. The remaining 22 isolates (8.8%) were either not identified or misidentified. The VITEK MS could not identify the 25 isolates absent from the IVD database to the species level. Conclusions: The VITEK MS showed reliable identifications for clinically relevant anaerobic bacteria.
Abstract
Background: By conventional methods, the identification of anaerobic bacteria is more time consuming and requires more expertise than the identification of aerobic bacteria. Although the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems are relatively less studied, they have been reported to be a promising method for the identification of anaerobes. We evaluated the performance of the VITEK MS in vitro diagnostic (IVD; 1.1 database; bioMérieux, France) in the identification of anaerobes. Methods: We used 274 anaerobic bacteria isolated from various clinical specimens. The results for the identification of the bacteria by VITEK MS were compared to those obtained by phenotypic methods and 16S rRNA gene sequencing. Results: Among the 249 isolates included in the IVD database, the VITEK MS correctly identified 209 (83.9%) isolates to the species level and an additional 18 (7.2%) at the genus level. In particular, the VITEK MS correctly identified clinically relevant and frequently isolated anaerobic bacteria to the species level. The remaining 22 isolates (8.8%) were either not identified or misidentified. The VITEK MS could not identify the 25 isolates absent from the IVD database to the species level. Conclusions: The VITEK MS showed reliable identifications for clinically relevant anaerobic bacteria.
참고문헌 (16)
- Murphy EC, "Gram-positive anaerobic cocci-commensals and opportunistic pathogens", FEMS Microbiol Rev, 37, pp.520~553 (2013)
- Nagy E, "Matrix-assisted laser desorption", ionization time-of-flight mass spectrometry: a new possibility for the identification and typing of anaerobic bacteria, 2014, pp.9, 217~233
- Wieser A, "MALDI-TOF MS in microbiological diagnostics-identification of microorganisms and beyond (mini review)", Appl Microbiol Biotechnol, 93, pp.965~974 (2012)
- Marko DC, "Evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry systems for identification of nonfermenting gram-negative bacilli isolated from cultures from cystic fibrosis patients", J Clin Microbiol, 50, pp.2034~2039 (2012)
- Culebras E, "Rapid identification of clinical isolates of Bacteroides species by matrix-assisted laser-desorption", ionization time-of-flight mass spectrometry, 2012, pp.18, 163~165
- Fedorko DP, "Identification of clinical isolates of anaerobic bacteria using matrix-assisted laser desorption ionization-time of flight mass spectrometry", Eur J Clin Microbiol Infect Dis, 31, pp.2257~2262 (2012)
- La Scola B, "Burden of emerging anaerobes in the MALDI-TOF and 16S rRNA gene sequencing era", Anaerobe, 17, pp.106~112 (2011)
- Nagy E, "The value of MALDI-TOF MS for the identification of clinically relevant anaerobic bacteria in routine laboratories", J Med Microbiol, 61, pp.1393~1400 (2012)
- Jamal WY, "Comparison of two matrix-assisted laser desorption", ionization-time of flight (MALDI-TOF) mass spectrometry methods and API 20AN for identification of clinically relevant anaerobic bacteria, 2013, pp.62, 540~544
- Dubois D, "Performances of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for rapid identification of bacteria in routine clinical microbiology", J Clin Microbiol, 50, pp.2568~2576 (2012)
- Clark AE, "Matrix-assisted laser desorption ionization-time of flight mass spectrometry: a fundamental shift in the routine practice of clinical microbiology", Clin Microbiol Rev, 26, pp.547~603 (2013)
- Chun J, "EzTaxon: a web-based tool for the identification of prokaryotes based on 16S ribosomal RNA gene sequences", Int J Syst Evol Microbiol, 57, pp.2259~2261 (2007)
- Clinical and Laboratory Standards Institute, "Interpretive criteria for identification of bacteria and fungi by DNA target sequencing. Approved guideline, MM18-A", Clinical and Laboratory Standards Institute, ~ (2008)
- Justesen US, "Species identification of clinical isolates of anaerobic bacteria: a comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry systems", J Clin Microbiol, 49, pp.4314~4318 (2011)
- Martiny D, "Comparison of the Microflex LT and Vitek MS systems for routine identification of bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry", J Clin Microbiol, 50, pp.1313~1325 (2012)
- Garner O, "Multi-centre evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK® MS system", Clin Microbiol Infect, 20, pp.355~359 (2014)
