Analytical and Clinical Validation of Six Commercial Middle East Respiratory Syndrome Coronavirus RNA Detection Kits Based on Real-Time Reverse-Transcription PCR

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: During the 2015 outbreak of Middle East Respiratory Syndrome coronavirus (MERS-CoV), six different commercial MERS-CoV RNA detection kits based on real-time reverse-transcription polymerase chain reaction (rRT-PCR) were available in Korea. We performed analytical and clinical validations of these kits. Methods: PowerChek (Kogene Biotech, Korea), DiaPlexQ (SolGent, Korea), Anyplex (Seegene, Korea), AccuPower (Bioneer, Korea), LightMix (Roche Molecular Diagnostics, Switzerland), and UltraFast kits (Nanobiosys, Korea) were evaluated. Limits of detection (LOD) with 95% probability values were estimated by testing 16 replicates of upstream of the envelope gene (upE) and open reading frame 1a (ORF1a) RNA transcripts. Specificity was estimated by using 28 nasopharyngeal swabs that were positive for other respiratory viruses. Clinical sensitivity was evaluated by using 18 lower respiratory specimens. The sensitivity test panel and the high inhibition panel were composed of nine specimens each, including eight and six specimens that were positive for MERS-CoV, respectively. Results: The LODs for upE ranged from 21.88 to 263.03 copies/reaction, and those for ORF1a ranged from 6.92 to 128.82 copies/reaction. No cross-reactivity with other respiratory viruses was found. All six kits correctly identified 8 of 8 (100%) positive clinical specimens. Based on results from the high inhibition panel, PowerChek and AccuPower were the least sensitive to the presence of PCR inhibition. Conclusions: The overall sensitivity and specificity of all six assay systems were sufficient for diagnosing MERS-CoV infection. However, the analytical sensitivity and detection ability in specimens with PCR inhibition could be improved with the use of appropriate internal controls.

Abstract

Background: During the 2015 outbreak of Middle East Respiratory Syndrome coronavirus (MERS-CoV), six different commercial MERS-CoV RNA detection kits based on real-time reverse-transcription polymerase chain reaction (rRT-PCR) were available in Korea. We performed analytical and clinical validations of these kits. Methods: PowerChek (Kogene Biotech, Korea), DiaPlexQ (SolGent, Korea), Anyplex (Seegene, Korea), AccuPower (Bioneer, Korea), LightMix (Roche Molecular Diagnostics, Switzerland), and UltraFast kits (Nanobiosys, Korea) were evaluated. Limits of detection (LOD) with 95% probability values were estimated by testing 16 replicates of upstream of the envelope gene (upE) and open reading frame 1a (ORF1a) RNA transcripts. Specificity was estimated by using 28 nasopharyngeal swabs that were positive for other respiratory viruses. Clinical sensitivity was evaluated by using 18 lower respiratory specimens. The sensitivity test panel and the high inhibition panel were composed of nine specimens each, including eight and six specimens that were positive for MERS-CoV, respectively. Results: The LODs for upE ranged from 21.88 to 263.03 copies/reaction, and those for ORF1a ranged from 6.92 to 128.82 copies/reaction. No cross-reactivity with other respiratory viruses was found. All six kits correctly identified 8 of 8 (100%) positive clinical specimens. Based on results from the high inhibition panel, PowerChek and AccuPower were the least sensitive to the presence of PCR inhibition. Conclusions: The overall sensitivity and specificity of all six assay systems were sufficient for diagnosing MERS-CoV infection. However, the analytical sensitivity and detection ability in specimens with PCR inhibition could be improved with the use of appropriate internal controls.

참고문헌 (14)

  1. Cowling BJ, "Preliminary epidemiological assessment of MERS-CoV outbreak in South Korea", Euro Surveill, 20, pp.7~13 (2015)
  2. Park HY, "Epidemiological investigation of MERS-CoV spread in a single hospital in South Korea", Euro Surveill, 20, pp.1~6 (2015)
  3. "Laboratory testing for Middle East Respiratory Syndrome Coronavirus" (2014)[URL]
  4. "Laboratory testing for Middle East Respiratory Syndrome Coronavirus (MERS-CoV)"[URL]
  5. Lu X, "Real-time reverse transcription-PCR assay panel for Middle East respiratory syndrome coronavirus", J Clin Microbiol, 52, pp.67~75 (2014)
  6. "Information for Laboratories"[URL]
  7. Corman VM, "Assays for laboratory confirmation of novel human coronavirus (hCoV-EMC) infections", Euro Surveill, 17 (2012)
  8. Corman VM, "Detection of a novel human coronavirus by real-time reverse-transcription polymerase chain reaction", Euro Surveill, 17 (2012)
  9. Corman VM, "Performance and clinical validation of the RealStar MERS-CoV Kit for detection of Middle East respiratory syndrome coronavirus RNA", J Clin Virol, 60, pp.168~171 (2014)
  10. Madej RM, "International standards and reference materials for quantitative molecular infectious disease testing", J Mol Diagn, 12, pp.133~143 (2010)
  11. Kraft CS, "Interpreting quantitative cytomegalovirus DNA testing: understanding the laboratory perspective", Clin Infect Dis, 54, pp.1793~1797 (2012)
  12. Schnepf N, "Fully automated quantification of cytomegalovirus (CMV) in whole blood with the new sensitive Abbott RealTime CMV assay in the era of the CMV international standard", J Clin Microbiol, 51, pp.2096~2102 (2013)
  13. "Preliminary analysis of Middle East respiratory syndrome coronavirus (MERS-CoV) sequences from Korea and China"[URL]
  14. Clinical and Laboratory Standards Institute, "Quantitative molecular methods for infectious disease. Approved guideline-second edition, MM06-A2", Clinical and Laboratory Standard Institutete, ~ (2010)

관련 논문AI추천

Performance Evaluation of the PowerChek MERS (upE & ORF1a) Real-Time PCR Kit for the Detection of Middle East Respiratory Syndrome Coronavirus RNA권현정, 기창석, 김종원, 김지연, 윤선애, 이남용, 이명근, 허희재대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제6호External Quality Assessment of MERS-CoV Molecular Diagnostics During the 2015 Korean Outbreak고경필, 김미나, 김의종, 김재석, 김택수, 박성섭, 성문우, 성흥섭, 안지수, 유병수, 이승준, 조성임대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제3호Importance of Specimen Type and Quality in Diagnosing Middle East Respiratory Syndrome강은숙, 강지만, 강철인, 고재훈, 기창석, 김영은, 김예진, 김종원, 박창훈, 백경란, 송재훈, 유신애, 이남용, 이명근, 정두련, 조선영, 최리화, 하영은, 허희재, 홍지혜대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제1호Guidelines for the Laboratory Diagnosis of Middle East Respiratory Syndrome Coronavirus in Korea기창석, 김미나, 김신영, 김재석, 김정호, 성문우, 성흥섭, 용동은, 이미경, 이혁민, 최종락대한감염학회 · Infection and Chemotherapy2016 · 제48권 제1호Korean Society for Laboratory Medicine Practice Guidelines for the Molecular Diagnosis of Middle East Respiratory Syndrome During an Outbreak in Korea in 2015기창석, 김미나, 김신영, 김재석, 김정호, 성문우, 성흥섭, 용동은, 이미경, 이혁민, 최종락, The Korean Society for Laboratory Medicine MERS-CoV Laboratory Response Task Force대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제3호Evaluation of a Multiplex Real-time PCR Assay for the Detection of Respiratory Viruses in Clinical Specimens김종완, 김태현, 박주원, 임인수대한진단검사의학회 · Annals of Laboratory Medicine2012 · 제32권 제6호

이 간행물의 다른 논문 (18건)