Utility of an Automatic Vision-Based Examination System (AVE-562) for the Detection of Clonorchis sinensis Eggs in Stool
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Stool examination is the gold standard for the detection of intestinal parasites. We assessed the performance of a newly developed AVE-562 analyzer (AVE Science & Technology Co., Hunan, China) for the vision-based detection of eggs of Clonorchis sinensis—the most common intestinal parasite in Korea—in stool samples. In total, 30 stool samples with a high or low egg count or without eggs (as negative control samples) (N=10 each) were prepared and analyzed. The performance of the AVE-562 analyzer was compared with that of the formalin-ether concentration (FEC) method. The overall correct identification rate of the AVE-562 analyzer based on FEC results was 66.6%. The sensitivity, specificity, positive predictive value, and negative predictive value of the AVE-562 analyzer for detecting C. sinensis eggs were 36.4%, 100.0%, 100.0%, and 73.1%, respectively. The average time required to run five tests simultaneously was 27 min using the AVE-562 analyzer and 58 min using the FEC method. Although the AVE-562 analyzer enables rapid and convenient stool examination, its sensitivity needs to be improved, particularly considering the prevalence of low-burden C. sinensis infection in Korea.
Abstract
Stool examination is the gold standard for the detection of intestinal parasites. We assessed the performance of a newly developed AVE-562 analyzer (AVE Science & Technology Co., Hunan, China) for the vision-based detection of eggs of Clonorchis sinensis—the most common intestinal parasite in Korea—in stool samples. In total, 30 stool samples with a high or low egg count or without eggs (as negative control samples) (N=10 each) were prepared and analyzed. The performance of the AVE-562 analyzer was compared with that of the formalin-ether concentration (FEC) method. The overall correct identification rate of the AVE-562 analyzer based on FEC results was 66.6%. The sensitivity, specificity, positive predictive value, and negative predictive value of the AVE-562 analyzer for detecting C. sinensis eggs were 36.4%, 100.0%, 100.0%, and 73.1%, respectively. The average time required to run five tests simultaneously was 27 min using the AVE-562 analyzer and 58 min using the FEC method. Although the AVE-562 analyzer enables rapid and convenient stool examination, its sensitivity needs to be improved, particularly considering the prevalence of low-burden C. sinensis infection in Korea.
참고문헌 (16)
- Ojha SC, "Geohelminths:public health significance", J Infect Dev Ctries, 8, pp.5~16 (2014)
- 홍성태, "A successful experience of soil-transmitted helminth control in the Republic of Korea", Parasites, Hosts and Diseases, 44(3), pp.177~185 (2006), 대한기생충학ㆍ열대의학회
- 김동수, "A Nationwide Survey on the Prevalence of Intestinal Parasitic Infections in the Republic of Korea, 2004", Parasites, Hosts and Diseases, 47(1), pp.37~47 (2009), 대한기생충학ㆍ열대의학회
- National survey of the prevalence of intestinal parasitic infections in Korea, 2012. The 8th Report, "Korea Centers for Disease Control and Prevention", Osong, ~ (2013)
- Young-Il Jeong, "Prevalence of Clonorchis sinensis Infection among Residents along 5 Major Rivers in the Republic of Korea", Parasites, Hosts and Diseases, 54(2), pp.215~219 (2016), 대한기생충학ㆍ열대의학회
- Li HM, "Performance evaluation of existing immunoassays for Clonorchis sinensis infection in China", Parasit Vectors, 11, pp.35~ (2018)
- Flávia Thamiris Figueiredo Pacheco, "Specific IgG and IgA Antibody Reactivities in Sera of Children by Enzyme-Linked Immunoassay and Comparison With <italic>Giardia duodenalis<", italic> Diagnosis in Feces, 2020, pp.40(5), 382~389[DOI]
- Rahman SMM, "Application of a loop-mediated isothermal amplification (LAMP) assay targeting cox1 gene for the detection of Clonorchis sinensis in human fecal samples", PLoS Negl Trop Dis, 11, pp.e0005995~ (2017)
- Won EJ, "Multiplex realtime PCR assay targeting eight parasites customized to the Korean population: potential use for detection in diarrheal stool samples from gastroenteritis patients", PLoS One, 11, pp.e0166957~ (2016)
- 원은정, "Evaluation of Modified Formalin-Ether Concentration Method Using Para Tube in Clinical Settings", Annals of Laboratory Medicine, 35(4), pp.445~448 (2015), 대한진단검사의학회
- McHardy IH, "Detection of intestinal protozoa in the clinical laboratory", J Clin Microbiol, 52, pp.712~720 (2014)
- Han S, "A combination of the Kato-Katz methods and ELISA to improve the diagnosis of clonorchiasis in an endemic area, China", PLoS One, 7, pp.e46977~ (2012)
- Yang YS, "Automatic identification of human helminth eggs on microscopic fecal specimens using digital image processing and an artificial neural network", IEEE Trans Biomed Eng, 48, pp.718~730 (2001)
- Intra J, "Detection of intestinal parasites by use of the cuvette-based automated microscopy analyser sedi MAX®", Clin Microbiol Infect, 22, pp.279~284 (2016)
- Intra J, "Improvement in the detection of enteric protozoa from clinical stool samples using the automated urine sediment analyzer sediMAX® 2 compared to sediMAX® 1", Eur J Clin Microbiol Infect Dis, 36, pp.147~151 (2017)
- Anwar SM, "Medical image analysis using convolutional neural networks: a review", J Med Syst, 42, pp.226~ (2018)
