Questionnaire Survey on Current Red Blood Cell Transport and Storage in Korea for Reducing Wastage
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: To ensure safe red blood cell (RBC) transfusion practice, it is important to comply with storage and transport requirements of RBC units. We conducted a comprehensive survey on the practice of RBC transport and storage to explore the awareness of and compliance with the 30-minute rule, the current status of RBC unit transport, and possible utility of temperature indicators (TIs) to reduce RBC wastage. Methods: From June to August of 2019, 64 blood bank physicians (14 questions) in 64 secondary- and tertiary-care hospitals and 673 nurses (13 questions) in 42 tertiary-care hospitals replied to a questionnaire survey. The results of the survey were analyzed with descriptive statistics. Results: Among the physicians surveyed, 97.0% (N=62) of hospitals had transfusion guidelines in place. The RBC wastage in 2018 ranged from less than five units to more than 200 units. Among the nurses surveyed, 99.4% (N=669) were aware of and complied with the 30-minute rule; 13.5% (N=91) of the nurses had experience of RBC wastage due to violation of the 30-minute rule. Both physicians (67%, N=43) and nurses (83.1%, N=559) responded that TIs would help reduce RBC wastage. Conclusions: This is the first survey on the practices related to RBC transport and storage in Korea. This study provides fundamental data on current practice for the blood cold chain, insights into RBC wastage, and highlights the utility of TIs.
Abstract
Background: To ensure safe red blood cell (RBC) transfusion practice, it is important to comply with storage and transport requirements of RBC units. We conducted a comprehensive survey on the practice of RBC transport and storage to explore the awareness of and compliance with the 30-minute rule, the current status of RBC unit transport, and possible utility of temperature indicators (TIs) to reduce RBC wastage. Methods: From June to August of 2019, 64 blood bank physicians (14 questions) in 64 secondary- and tertiary-care hospitals and 673 nurses (13 questions) in 42 tertiary-care hospitals replied to a questionnaire survey. The results of the survey were analyzed with descriptive statistics. Results: Among the physicians surveyed, 97.0% (N=62) of hospitals had transfusion guidelines in place. The RBC wastage in 2018 ranged from less than five units to more than 200 units. Among the nurses surveyed, 99.4% (N=669) were aware of and complied with the 30-minute rule; 13.5% (N=91) of the nurses had experience of RBC wastage due to violation of the 30-minute rule. Both physicians (67%, N=43) and nurses (83.1%, N=559) responded that TIs would help reduce RBC wastage. Conclusions: This is the first survey on the practices related to RBC transport and storage in Korea. This study provides fundamental data on current practice for the blood cold chain, insights into RBC wastage, and highlights the utility of TIs.
참고문헌 (33)
- Lelubre C, "Red blood cell transfusion in the critically ill patient", Ann Intensive Care, 1, pp.43~ (2011)
- de Bruin S, "Cardiovascular Dynamics Section and Transfusion Guideline Task Force of the ESICM. Transfusion practice in the non-bleeding critically ill: an international online survey-the TRACE survey", Crit Care, 23, pp.309~ (2019)
- Alquist CR, "Technical manual", pp.503~535 (2020), American Association of Blood Banks
- "Transfusion guideline"[URL]
- Park M, "Utility of temperature-sensitive indicators for temperature monitoring of red-blood-cell units", Vox Sang, 114, pp.487~494 (2019)
- Pick P, "Temperature changes in donor blood under different storage conditions", Transfusion, 11, pp.213~215 (1971)
- "Clinical transfusion practice"[URL]
- "The blood cold chain"[URL]
- Yazer MH, "International Society for Blood Transfusion international survey on blood product wastage in hospitals", ISBT Sci Ser, 11, pp.24~31 (2016)
- Hamill TR, "The 30-minute rule for reissuing blood : are we needlessly discarding units?", Transfusion, 30, pp.58~62 (1990)
- Dumani D, "Is the 30-minute rule still applicable in the 21st century?", Transfusion, 53, pp.1150~1152 (2013)
- Kurup R, "A study on blood product usage and wastage at the public hospital, Guyana", BMC Res Notes, 9, pp.307~ (2016)
- "NHS blood stocks management scheme. NHS Blood and Transplant/hospital report 2017-18"[URL]
- Johnson V, "Temperature-sensitive labels for containers of RBCs", Am J Clin Pathol, 126, pp.406~410 (2006)
- Sigle JP, "Temperature-sensitive indicators for monitoring RBC concentrates out of controlled temperature storage", Am J Clin Pathol, 144, pp.145~150 (2015)
- Tiwari AK, "A cost effective model for appropriate administration of red cell units and salvaging un-transfused red cell units by using temperature sensitive indicators for blood component transportation in a hospital setting", Asian J Transfus Sci, 9, pp.36~40 (2015)
- Park M, "Time–temperature indicators versus temperature indicators for transfusion practice : application in the real hospital setting", Vox Sang (2021)[DOI]
- Bots M, "Strategies to reduce wastage of red blood cell units", Vox Sang, 110, pp.143~149 (2016)
- Gallagher T, "Patient blood management nurse vs transfusion nurse : is it time to merge?", Br J Nurs, 24, pp.492~495 (2015)
- Nakamura Y, "A survey of nurses to assess transfusion practice at the bedside using an electronic identification system : experience at a university hospital", Transfus Med, 31, pp.5~10 (2021)
- Ddungu H, "Survey to assess knowledge and reported practices regarding blood transfusion among cancer physicians in Uganda", J Glob Oncol, 4, pp.1~12 (2018)
- Islami Vaghar M, "The impact of an educational program on blood and blood products transfusion on nurses’ level of knowledge and performance", J Med Life, 11, pp.238~242 (2018)
- 김병철, "한 대학병원의 혈액 폐기 분석", 대한수혈학회지, 22(2), pp.120~126 (2011), 대한수혈학회
- "SPECIFICATION SPN223/10 NHSBT portfolio of blood components and guidance for their clinical use"[URL]
- Thomas S, "The 30 minute rule for red blood cells : in vitro quality assessment after repeated exposure to 30°C", Transfusion, 53, pp.1169~1177 (2013)
- Ramirez-Arcos S, "Evaluating the 4-hour and 30-minute rules : effects of room temperature exposure on red blood cell quality and bacterial growth", Transfusion, 53, pp.851~859 (2013)
- Ramirez-Arcos S, "Changing the 30-min rule in Canada : the effect of room temperature on bacterial growth in red blood cells", Transfus Med Hemother, 43, pp.396~399 (2016)
- Aplin K, "Extending the 30-minute rule for red cell units–investigation of the bacterial risk of 60-minute exposures to ambient temperature", Vox Sang, 114, pp.189~197 (2019)
- Stanworth SJ, "Effects of the COVID-19 pandemic on supply and use of blood for transfusion", Lancet Haematol, 7, pp.e756~e764 (2020)
- Müller-Steinhardt M, "Safety and frequency of whole blood donations from elderly donors", Vox Sang, 102, pp.134~139 (2012)
- Ali A, "The aging population poses a global challenge for blood services", Transfusion, 50, pp.584~588 (2010)
- Heitmiller ES, "Blood wastage reduction using Lean Sigma methodology", Transfusion, 50, pp.1887~1896 (2010)
- 천세종, "국가 혈액수급감시체계의 전수감시에 대한 의료기관의 준비현황에 대한 설문조사", 대한수혈학회지, 31(3), pp.211~221 (2020), 대한수혈학회[DOI]
