CT 방법을 이용한 질량감쇠계수 결정 및 자체감쇠 보정
Determination of Mass Attenuation Coefficient and Self-Attenuation Correction Using the CT Method
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, the mass attenuation coefficients for all five of the IAEA referencematerial samples (apparent density in a measuring bottle: 0.50~1.45 g·cm-3), including soil, milkpowder, hay and moss soil, were determined using the CT (Calibration Transmission) method. Acertified mixed gamma-ray sources including 241Am, 88Cd, 57Co, 113Sn, 85Sr and 137Cs were added tothe IAEA reference samples for the validation of present method. The self-attenuation correctionfactors for the gamma-ray energies of 59.5 keV, 88 keV, 122.1 keV, 391.7 keV, 514 keV and 661.7keV were determined and applied to the self-attenuation correction. As a result, the accuracy ofgamma-ray spectrometry for environmental samples used in this study was improved especiallyfor lower energy gamma-ray emitting radionuclides.
Abstract
In this study, the mass attenuation coefficients for all five of the IAEA referencematerial samples (apparent density in a measuring bottle: 0.50~1.45 g·cm-3), including soil, milkpowder, hay and moss soil, were determined using the CT (Calibration Transmission) method. Acertified mixed gamma-ray sources including 241Am, 88Cd, 57Co, 113Sn, 85Sr and 137Cs were added tothe IAEA reference samples for the validation of present method. The self-attenuation correctionfactors for the gamma-ray energies of 59.5 keV, 88 keV, 122.1 keV, 391.7 keV, 514 keV and 661.7keV were determined and applied to the self-attenuation correction. As a result, the accuracy ofgamma-ray spectrometry for environmental samples used in this study was improved especiallyfor lower energy gamma-ray emitting radionuclides.
참고문헌 (7)
- Al-Masri MS, "Mass attenuation coefficients of soil and sediment samples using gamma energies from 46.5 to 1332 keV", J. Environ. Radioact., 116, pp.28~33 (2013)
- Berger MJ, "XCOM: photon cross section database(version 1.5)", National Institute of Standards and Technology, ~ (2010)
- Byun JI, "A calibration transmission method to determine the gamma-ray linear attenuation coefficient without a collimator", Appl. Radiat. Isot., 102, pp.70~73 (2015)
- Carrazana Gonzalez J, "The effect of source chemical composition on the self-attenuation corrections for low-energy gamma-rays in soil samples", Appl. Radiat. Isot., 68, pp.360~363 (2010)
- Cutshall NH, "Direct analysis of 210Pb in sediment samples: Self-absorption corrections", Nucl. Instr. Method. Phys. Res., 206(1-2), pp.309~312 (1983)
- Debertin K, "Gamma- and X-ray spectrometry with semiconductor detectors", pp.281~286 (1988), North-Holland Publishing Company
- Hubell JH, "Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV", Appl. Radiat. Isot., 33(11), pp.1269~1290 (1982)
