수직관 길이에 따른 버블펌프의 성능평가에 관한 연구
A Study on the Performance Characteristics of Bubble Pump with Vertical Pipe Lengths
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study is on the performance characteristics of bubble pump with vertical pipe of different lengths. For the experimental facilities composed of electrical heater used for providing heat source to generate bubble, a vertical tube with Ø4mm diameter, length of 200mm, 300mm, 400mm and 500mm. Storage tank with capacity was of 40 L containing a heat exchanger. The separator and condenser of the air bubble pump were installed separately. The results obtained from this experiment are as follows: there were a few variations of values of temperatures according to vertical pipe lengths of the bubble pump. The mass flow rate was increased by 0.17g/s when it was short as 200㎜ long pipe. But when vertical pipe length was 500㎜, it reached the normal temperature quickly because the slug flow occurred in this case at initial stage. Consequently, it was found that 500㎜ of the vertical pipe length was optimum for best performance of bubble pump.
Abstract
This study is on the performance characteristics of bubble pump with vertical pipe of different lengths. For the experimental facilities composed of electrical heater used for providing heat source to generate bubble, a vertical tube with Ø4mm diameter, length of 200mm, 300mm, 400mm and 500mm. Storage tank with capacity was of 40 L containing a heat exchanger. The separator and condenser of the air bubble pump were installed separately. The results obtained from this experiment are as follows: there were a few variations of values of temperatures according to vertical pipe lengths of the bubble pump. The mass flow rate was increased by 0.17g/s when it was short as 200㎜ long pipe. But when vertical pipe length was 500㎜, it reached the normal temperature quickly because the slug flow occurred in this case at initial stage. Consequently, it was found that 500㎜ of the vertical pipe length was optimum for best performance of bubble pump.
참고문헌 (8)
- L.Chen, "The effect of tube diameter on vertical two-phase flow regimes in small tubes", Int.J,Heat and Mass Transfer, 49(21), pp.4220~4230 (2006)
- Chisholm,D, "Two-Phase Flow in Pipelines and heat Exchangers", George Godwin London and New York, ~ (1983)
- Wallis,G.B, "One Dimensional Two-Phase Flow" (1969), McGraw Hill
- 고한서, "Experimental Analysisof Unsteady Bubble Behaviors Using Three-Dimensional Tomography", 비파괴검사학회지, 25(6), pp.431~438 (2005), 한국비파괴검사학회
- Sorensen W, "The Bubble Pumped D.H.W. System", ISES Solar World Congress (1987)
- Lavin,J.G, "A Heat Transfer to Evaporating Refrigerants in Two-Phase Flow", A.I.Ch.E J, 11(6), pp.1124~ (1965)
- Hoffman,E.W, "The Bubble Action Pump Solar Heating System", ~ (1985)
- 이재효, "확산형 흡수식 냉동시스템의 기포펌프 성능실험", 설비공학 논문집, 16(3), pp.287~292 (2004), 대한설비공학회