초록

The temperature distribution of a generic battery module was analyzed for different flow rates of cooling fluid. For the given battery module design, the temperature of battery cell near the inlet is higher than that of battery cell near the outlet. Because the inlet is located at the higher elevation than the top of battery electrodes, most of the incoming cooling fluid flows directly towards the battery housing wall above the outlet. For the inlet velocities of 1, 3, 5 m/s, the maximum temperature differences are 28, 19, 15 degrees Celcius respectively.

Abstract

The temperature distribution of a generic battery module was analyzed for different flow rates of cooling fluid. For the given battery module design, the temperature of battery cell near the inlet is higher than that of battery cell near the outlet. Because the inlet is located at the higher elevation than the top of battery electrodes, most of the incoming cooling fluid flows directly towards the battery housing wall above the outlet. For the inlet velocities of 1, 3, 5 m/s, the maximum temperature differences are 28, 19, 15 degrees Celcius respectively.

참고문헌 (10)

  1. 류의환, "고분자 전해질 연료전지의 Cathode 반응가스 흐름방향에 따른 성능 분석", 한국기계기술학회지, 15(1), pp.97~102 (2013), 한국기계기술학회
  2. 류의환, "EnergyPlus를 활용한 농어촌 주택 태양광 시스템의 손익분기점 분석", 한국기계기술학회지, 14(6), pp.57~62 (2012), 한국기계기술학회
  3. K. S. Kim, "Study of Hybrid Car Development for Education", Proceedings of Korean Society of Mechanical Technology '09 Winter Annual Conference, pp.51~57 (2009)
  4. 김현수, "전기자동차용 배터리 팩 주위의 유동장 해석", 한국전산유체공학회지, 16(3), pp.82~87 (2011), 한국전산유체공학회
  5. The Korean Society of Automotive Engineers, "Automotive Technology and Outlook" (2011)
  6. I. H. Jang, "Analysis of Forced Cooling Efficiency According to Case of HEV Battery Module", Proceedings of the Korean Society of Mechanical Engineers '10 Spring Annual Conference, pp.252~257 (2010)
  7. J. S. Lee, "An Analytical Approach for the Battery Cooling of Hybrid Battery Package", Proceedings of the Korean Society of Automotive Engineers '11 Annual Conference, pp.508~514 (2011)
  8. I. H. Jang, "Analysis of Cooling Efficiency According to Inlet", Outlet Position of HEV Battery Module, 2010, 3457~3460
  9. C. R. Sung, "Numerical Study on Improvement of the Cooling Performance for the Battery Formation Equipment", Proceedings of the Korean Society of Mechanical Engineers '10 Autumn Annual Conference, pp.3146~3151 (2010)
  10. "Mitsubishi i-MiEV"[URL]

관련 논문AI추천

이 간행물의 다른 논문 (13건)