In the present study, single-phase heat transfer characteristics for downstream flow in the support grid of 6×6 rod bundle were investigated. It has been known that a turbulence generation due to a support grid with split mixing vanes enhances heat transfer in rod bundle but its heat transfer enhancement actually affects to relativelyshorter distance. On the other hand, it has been also turned out that a support grid with large scale vortex flow(LSVF) mixing vanes results in heat transfer enhancement to a longer distance. Based on the results of literatre survey, single-phase water heat transfer experiments were performed for Reynolds numbers at around 30,000, and the heat transfer enhancement effect with both i) the split mixing vanes and ii) the LSVF mixing vanes was compared in this study. The key results showed that the effect of heat transfer enhancement in rod bundle region by the split mixing vanes was maintained up to the length of 15Dh behind the spacer grid. For the Reynolds numbers at around 30,000, it was also observed that the effect using the LSVF mixing vanes was stronger at about 3% when compared to the case using the split mixing vanes only for the distance ranging from 1 to 15Dh behind the spacer grid.
Abstract
In the present study, single-phase heat transfer characteristics for downstream flow in the support grid of 6×6 rod bundle were investigated. It has been known that a turbulence generation due to a support grid with split mixing vanes enhances heat transfer in rod bundle but its heat transfer enhancement actually affects to relativelyshorter distance. On the other hand, it has been also turned out that a support grid with large scale vortex flow(LSVF) mixing vanes results in heat transfer enhancement to a longer distance. Based on the results of literatre survey, single-phase water heat transfer experiments were performed for Reynolds numbers at around 30,000, and the heat transfer enhancement effect with both i) the split mixing vanes and ii) the LSVF mixing vanes was compared in this study. The key results showed that the effect of heat transfer enhancement in rod bundle region by the split mixing vanes was maintained up to the length of 15Dh behind the spacer grid. For the Reynolds numbers at around 30,000, it was also observed that the effect using the LSVF mixing vanes was stronger at about 3% when compared to the case using the split mixing vanes only for the distance ranging from 1 to 15Dh behind the spacer grid.
참고문헌 (9)
- K. Rehme, "Pressure drop correlations for fuel element spacers", Nucl. Technol, 17, pp.15~23 (1973)
- Measurement of turbulent velocity, intensity and scale in rod bundle flow channels containing a grid spacer, "D. S. Dowe", BNWL, ~, pp.BNWL-1757 (1973)
- Heat transfer in a decaying vortex system, "H. A. Blum", ASME, ~, pp.ASME Paper No. 66-WA (1996), HT-62
- S. K. Chang, "Phenomenological investigations on the turbulent flow structures in a rod bundle array with mixing devices", Nucl. Eng. and Design, 238, pp.600~609 (2008)
- S. K. Chang, "Turbulent mixing in a rod bundle with vaned spacer grids:OECD", NEA-KAERI CFD benchmark exercise test, 2014, pp.279, 19~36
- 안정수, "핵연료 집합체에서의 대형 이차 와류 혼합날개의 난류생성 특성에 관한 연구", 설비공학 논문집, 18(10), pp.811~818 (2006), 대한설비공학회
- C. H. Shin, "Effect of mixing vane shapes of spacer grids in nuclear fuel assembly on critical heat flux", Proc. of the KSME 2007 Spring Annual Meeting, pp.3049~3054 (2007)
- C. M. Lee, "Comparison of thermohydraulic performances of large scale vortex flow (LSVF) and small scale vortex flow(SSVF) Mixing Vanes in 17×17 nuclear rod bundle", Nucl. Eng. and Design, 237, pp.2322~2331 (2007)
- 변선준, "혼합날개가 부착된 6×6 봉다발 부수로에서의 열전달 향상을 위한 실험적 연구", 한국기계기술학회지, 17(2), pp.231~237 (2015), 한국기계기술학회[DOI]