저온영역에서의 친환경 냉매용 냉동장치의 성능 분석
Performance Analysis of Refrigeration System for Eco-friendly Refrigerants in Low Temperature Range
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this paper, cycle performance analysis of two-stage compression two-stage expansion refrigeration system using eco-friendly refrigerants is presented to offer the basic design data for the operating parameters of the system. Eco-friendly refrigerant R600a(Isobutane) for freon refrigerant R22 were used working fluids in this study. The coefficient of performance(COP) of R600a is about 5% greater than that of R22 two-stage compression refrigeration system in the range of evaporation temperature –30℃∼-60℃. The coefficient of performance of two-stage compression and two-stage expansion refrigeration system decreases with the increasing condensation temperature and superheating degree but increases with the increasing evaporation temperature, subcooling degree and mass flow rate ration of intercooler.
Abstract
In this paper, cycle performance analysis of two-stage compression two-stage expansion refrigeration system using eco-friendly refrigerants is presented to offer the basic design data for the operating parameters of the system. Eco-friendly refrigerant R600a(Isobutane) for freon refrigerant R22 were used working fluids in this study. The coefficient of performance(COP) of R600a is about 5% greater than that of R22 two-stage compression refrigeration system in the range of evaporation temperature –30℃∼-60℃. The coefficient of performance of two-stage compression and two-stage expansion refrigeration system decreases with the increasing condensation temperature and superheating degree but increases with the increasing evaporation temperature, subcooling degree and mass flow rate ration of intercooler.
참고문헌 (11)
- S. Sawalha, "Theoretical evaluation of trans-critical CO2 system in supermarket refrigeration. Part I : Modeling simulation and optimization of two system solutions", ASHRAE J, 47(8), pp.26~30 (2004)
- 노건상, "대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측", 한국기계기술학회지, 13(1), pp.73~80 (2011), 한국기계기술학회[DOI]
- S. N. Park, "Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant", pp.1999
- J. A. Dopazo, "Theoretical analysis of a CO2-NH3 cascade refrigeration system for cooling applications at low temperatures", Applied Thermal Engineering, 29, pp.1577~1583 (2009)
- A. Messineo, "LNG cold energy use in agro-food industry: a case study in Sicity", Journal of Natural Gas Science and Engineering, 3, pp.356~363 (2011)
- R. Liopis, "Performance evaluation of R404A and R507A refrigerant mixtures in an experimental double-stage vapour compression plant", pp.1546~1553 (2010), Department of Mechanical Engineering and Construction Campus de Riu Sec, Jaume I University
- E. Torrella, "general methodology for energy comparison of intermediate configurations in two-stage vapour compression refrigeration systems", pp.4119~4124 (2011), Department of Applied Thermodynamics, Polytechnic University of Valencia
- 김광홍, "발전소 대용량 터빈의 성능분석 사례연구", 한국기계기술학회지, 14(5), pp.73~79 (2012), 한국기계기술학회[DOI]
- fChart Software Inc, "Engineering Equation Solver", ~ (2010)
- A. Hiren, "Comparative Assessment of a Cascade Refrigeration Cycle with Different Refrigerant Pair", pp.8~10 (2011), Institute of Technology, NIRMA University
- A. Messineo, "744-R717 Cascade Refrigeration System : Performance evaluation compared with a HFC two-stage system", Energy Procedia, 14, pp.56~65 (2012)