청신경종양에서 나타나는 청성뇌간반응 잠복기의 진단적 가치
Diagnostic Value of the ABR Latency in the Acoustic Neuroma
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background and Objectives:It is important to rule out acoustic neuroma when treating patients who have tinnitus or monaural hearing loss. The most accurate diagnostic tool is MRI but due to high costs, auditory brainstem response (ABR) latency is often used. The aim of this study is to confirm the diagnostic value of ABR latency in acoustic neuroma. Patients and Methods:The medical records of 20 patients who were diagnosed acoustic neuroma in MRI and evaluated with pure tone audiometry, speech audiometry and ABR were retrospectively reviewed from January, 2003 to January, 2010. Tumor size and hearing classification system of 2003 Consensus Meeting was used. Using I-V interpeak latency (IPL) and I-V interlatency difference (ILD), we identified the diagnostic value of ABR latency in diagnosing acoustic neuroma. Results:Among 20 patients, there were 2 cases of intrameatal tumor, 2 cases of grade 1, 6 cases of grade 2, 6 cases of grade 3, 2 cases of grade 4 and 2 cases of grade 5according to the acoustic neuroma classification system of 2003 Consensus Meeting. There were 9 cases with no wave in ABR. 4 cases showed over 4.4 msec in I-V IPL and 6 cases showed over 0.2 msec in I-V ILD. There were 3 cases that showed over 4.4 msec in I-V IPL and over 0.2 msec in I-V ILD. Therefore, there were 16 cases that showed abnormal reactions to ABR among acoustic neuroma patients, false negative rate was founded to 20%. Conclusion:The smaller tumor size, the better prognosis in treating tumor and preserving hearing and facial nerve function, so that early diagnosis of acoustic neuroma is important. Because false negative rate of ABR was 20% in this study, using ABR as screening test of acoustic neuroma needs attention.
Abstract
Background and Objectives:It is important to rule out acoustic neuroma when treating patients who have tinnitus or monaural hearing loss. The most accurate diagnostic tool is MRI but due to high costs, auditory brainstem response (ABR) latency is often used. The aim of this study is to confirm the diagnostic value of ABR latency in acoustic neuroma. Patients and Methods:The medical records of 20 patients who were diagnosed acoustic neuroma in MRI and evaluated with pure tone audiometry, speech audiometry and ABR were retrospectively reviewed from January, 2003 to January, 2010. Tumor size and hearing classification system of 2003 Consensus Meeting was used. Using I-V interpeak latency (IPL) and I-V interlatency difference (ILD), we identified the diagnostic value of ABR latency in diagnosing acoustic neuroma. Results:Among 20 patients, there were 2 cases of intrameatal tumor, 2 cases of grade 1, 6 cases of grade 2, 6 cases of grade 3, 2 cases of grade 4 and 2 cases of grade 5according to the acoustic neuroma classification system of 2003 Consensus Meeting. There were 9 cases with no wave in ABR. 4 cases showed over 4.4 msec in I-V IPL and 6 cases showed over 0.2 msec in I-V ILD. There were 3 cases that showed over 4.4 msec in I-V IPL and over 0.2 msec in I-V ILD. Therefore, there were 16 cases that showed abnormal reactions to ABR among acoustic neuroma patients, false negative rate was founded to 20%. Conclusion:The smaller tumor size, the better prognosis in treating tumor and preserving hearing and facial nerve function, so that early diagnosis of acoustic neuroma is important. Because false negative rate of ABR was 20% in this study, using ABR as screening test of acoustic neuroma needs attention.
참고문헌 (17)
- Sidman JD, "Gadolinium: the new gold standard for diagnosing cerebellopontine angle tumors", Arch Otolaryngol Head Neck Surg, 115(1), pp.1244~1247 (1989)
- Chien S, "Ipsilateral and contralateral acoustic brainstem response abnormalities in patients with vestibular schwannoma", Otolaryngol Head Neck Surg, 141(6), pp.695~700 (2009)
- Rupa V, "Cost-effective initial screening for vestibular schwannoma: auditory brainstem response or magnetic resonance imaging?", Otolaryngol Head Neck Surg, 128(6), pp.823~828 (2003)
- Kanzaki J, "Audiological findings in acoustic neuroma", Acta Otolaryngol Suppl, 487, pp.125~132 (1991)
- Kanzaki J, "New and modified reporting systems from the consensus meeting on systems for reporting results in vestibular schwannoma", Otol Neurotol, 24(4), pp.642~649 (2003)
- Thomsen J, "Acoustic neuroma: clinical aspects, audiovestibular assesment, diagnostic delay and growth rate", Am J Otol, 11(1), pp.12~19 (1990)
- Berrettini S, "Acoustic neuroma; correlation between morphology and otoneurological manifestations", J Neurol Sci, 144(1-2), pp.24~33 (1996)
- Cheng G, "Cost comparison of auditory brainstem response versus magnetic resonance imaging screening of acoustic neuroma", J Laryngol Otol, 32(6), pp.394~399 (2003)
- Dort JC, "Power spectrum auditory brainstem response: novel approach to the evaluation of patients with unilateral auditory symptoms", J Laryngol Otol, 38(1), pp.59~66 (2009)
- Josey AF, "Correlation of ABR and medical imaging in patients with cerebellopontine angle tumors", Am J Otol, 88, pp.12~16 (1988)
- Selters WA, "Acoustic tumor detection with brainstem electric response audiometry", Arch Otolaryngol, 103(4), pp.181~187 (1977)
- Schmidt RJ, "The sensitivity of auditory brainstem response testing for the diagnosis of acoustic neuromas", Arch Otolaryngol Head Neck Surg, 127(1), pp.19~22 (2001)
- Zappia J, "Rethingking the use of auditory brainstem response in acoustic neuroma screening", Laryngoscope, 107(10), pp.1388~1392 (1997)
- Wilson DF, "The sensitivity of auditory brainstem response testing in small acoustic neuromas", Laryngoscope, 102(9), pp.961~964 (1992)
- Gordon M, "Efficacy of auditory brain stem response as a screening test for small acoustic neuromas", Am J Otol, 16(2), pp.136~139 (1995)
- Wiegand DA, "Surgical treatment of acoustic neuroma in the united states: report from acoustic neuroma registry", Laryngoscope, 106(1 Pt 1), pp.58~66 (1996)
- Cueva RA, "Auditory brainstem response versus magnetic resonance imaging for the evaluation of asymmetric sensorineural hearing loss", Laryngoscope, 114(10), pp.1686~1692 (2004)