입력 지진의 주파수 특성을 고려한 중력식 안벽의 수평지진계수에 대한 고찰
A Discussion on the Seismic Coefficient for Gravity Quay Wall Considering Frequency Characteristics of Input Earthquake
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Pseudo-static approach has been conventionally applied for the design of gravity type quay walls. In this method, seismic coefficient (kh), expressed in terms of acceleration due to gravity, is used to convert the real dynamic behavior to an equivalent pseudo-static inertial force for seismic analysis and design. Therefore, the calculation of an appropriate kh considering frequency characteristics of input earthquake is critical for representing the real dynamic behavior. However, the definitions of kh, which is used for simplified analysis in Korea, focuses only on convenience that is easy to use, and the frequency characteristics of input earthquake are not reflected in the kh definitions. This paper evaluates the influences of the frequency characteristics of input earthquake on kh by initially reviewing the kh definitions in the existing codes of Japan for port structures and then by performing a series of dynamic centrifuge tests on caisson gravity quay walls of different earthquake input motions (Ofunato, Hachinohe). A review of the existing codes and guidelines has shown that the kh values are differently estimated according to the frequency characteristics of input earthquake. On the other hand, based on the centrifuge tests, it was found that the permanent displacements of wall are more induced when long-period-dominant earthquake is applied.
Abstract
Pseudo-static approach has been conventionally applied for the design of gravity type quay walls. In this method, seismic coefficient (kh), expressed in terms of acceleration due to gravity, is used to convert the real dynamic behavior to an equivalent pseudo-static inertial force for seismic analysis and design. Therefore, the calculation of an appropriate kh considering frequency characteristics of input earthquake is critical for representing the real dynamic behavior. However, the definitions of kh, which is used for simplified analysis in Korea, focuses only on convenience that is easy to use, and the frequency characteristics of input earthquake are not reflected in the kh definitions. This paper evaluates the influences of the frequency characteristics of input earthquake on kh by initially reviewing the kh definitions in the existing codes of Japan for port structures and then by performing a series of dynamic centrifuge tests on caisson gravity quay walls of different earthquake input motions (Ofunato, Hachinohe). A review of the existing codes and guidelines has shown that the kh values are differently estimated according to the frequency characteristics of input earthquake. On the other hand, based on the centrifuge tests, it was found that the permanent displacements of wall are more induced when long-period-dominant earthquake is applied.
참고문헌 (19)
- Research of Seismic Design Criterea (II), "Ministry of Construction and Transportation", Earthquake Engineering Society of Korea, ~ (1997)
- Ministry of Oceans and Fisheries, "Seismic Design Standards of Harbor and Port", Earthquake Engineering Society of Korea, ~ (1999)
- 서형열, "사회기반시설물의 내진설계기준 개선방향에 대한 고찰", 한국지진공학회논문집, 18(5), pp.231~240 (2014), 한국지진공학회
- Seismic Performance evaluation & improvement revision of existing structures (Harbors), "Ministry of Land, Transport and Maritime Affairs", Korea Infrastructures Safety and Technology Corporation, ~ (2012)
- 이문교, "국내 중력식 안벽의 수평지진계수 산정 방법에 대한 고찰", 한국지진공학회논문집, 21(2), pp.77~85 (2017), 한국지진공학회
- Nozu A, "Seismic design of port structures", Journal of Japan Association for Earthquake Engineering, 4(3), pp.195~208 (2004)[DOI]
- Seismic Coefficients of Caisson Type and Sheet Pile Type Quay Walls Against the Level-one Earthquake Ground Motion, "Nagao T", National Institute for Land and Infrastructure Management, 1~26 (2006)
- Cakir T, "Evaluation of the Effect of Earthquake Frequency Content on Seismic Behavior of Cantilever Retaining Wall Including Soil-structure Interaction", Soil Dynamics and Earthquake Engineering, 45, pp.96~111 (2013)[DOI]
- Hatami K, "Effect of Structural Design on Fundamental Frequency of Reinforced-soil Retaining Walls", Soil Dynamics and Earthquake Engineering, 19(3), pp.137~157 (2000)[DOI]
- Lee MG, "Assessment of Horizontal Seismic Coefficient for Gravity Quay Walls by Centrifuge Tests", Geotechnique Letters, 7(2), pp.211~217 (2017)[DOI]
- Comite Europeen de Normalisation, "Eurocode 8: Design of Structures for Earthquake Resistance. Part 5: Foundations, Retaining Structures. Geotechnical Aspects", CEN, ~ (2004)
- Ministry of Transport, "Technical standards for Ports and Harbour Facilities in Japan. c1999 translated version of 港灣の施設物の技術上の基準‧同解說", 日本港灣協會, ~ (1999)
- Ministry of Transport, "Technical standards for Ports and Harbour Facilities in Japan. c2007 translated version of 港灣の施設物の技術上の基準‧同解說", 日本港灣協會, ~ (2007)
- Noda S, "Relation between Seismic Coefficient and Ground Acceleration for Gravity Quay Wall", Report of Port and Harbour Research Institute, 14(4), pp.67~111 (1975)
- 김동수, "A Newly Developed State-of-the-Art Geotechnical Centrifuge in Korea", KSCE Journal of Civil Engineering, 17(1), pp.77~84 (2013), 대한토목학회[DOI]
- Lee SH, "Performance of an Equivalent Shear Beam (ESB) Model Container for Dynamic Geotechnical Centrifuge Tests", Soil Dynamics and Earthquake Engineering, 44, pp.102~114 (2013)[DOI]
- Terzaghi K, "General Wedge Theory of Earth Pressure", American Society of Civil Engineers Transactions, 106, pp.68~97 (1941)
- Kim SR, "Evaluation of Seismic Displacements of Quay Walls", Soil Dynamics and Earthquake Engineering, 25, pp.451~459 (2005)[DOI]
- Zeng, "Seismic Response of Gravity Quay Walls. I: Centrifuge Modeling", Journal of Geotechnical and Geoenvironmental Engineering, 124(5), pp.406~417 (1998)[DOI]