FRP자켓 시스템이 보강된 비내진 철근콘크리트 골조의 실물 크기 강제 진동 실험
Forced Vibration Testing of Full-scale Non-seismic Reinforced Concrete Frame Structure Retrofitted Using FRP Jacketing System
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
Abstract
Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
참고문헌 (35)
- Bracci JM, "Seismic resistance of reinforced concrete frame structures designed for gravity loads: performance of structural system", ACI Structural Journal, 92(5), pp.597~609 (1995)
- Beres A, "Implications of experiments on the seismic behavior of gravity load designed RC beam-to-column connections", Earthquake Spectra, 12, pp.185~198 (1996)[DOI]
- Priestley MJN, "Displacement-based seismic assessment of reinforced concrete buildings", J Earthquake Eng, 1(1), pp.157~192 (1997)
- El-Attar AG, "Behavior of gravity load designed reinforced concrete buildings subjected to earthquake", ACI Structural Journal, 94(2), pp.133~145 (1997)
- Sause R, "Flexural behavior of concrete columns retrofitted with carbon fiber reinforced polymer jackets", ACI Structural Journal, 101(5), pp.708~716 (2004)
- Harries K, "Seismic retrofit of lap splices in nonductile columns using CFRP jackets", ACI Struct. J., 103(6), pp.226~236 (2006)
- Haroun MA, "Experimental investigation of seismic repair and retrofit of bridge columns by composite jackets", Journal of Reinforced Plastics and Composites, 22(14), pp.1243~1268 (2003)[DOI]
- State-of-the-art review of highway bridge columns retrofitted with FRP jackets, "Lan YM", School of Civil Engineering Purdue University, ~, pp.Department Report CE-STR-98-5 (1998)
- Saatcioglu M, "Strength and ductility of confined concrete", J Struct Eng, 118(6), pp.1590~1607 (1992), ASCE[DOI]
- Xiao Y, "Compressive behavior of concrete confined by carbon fiber composite jackets", Journal of Material for Civil Engineering, 12(2), pp.139~146 (2000)[DOI]
- Fam AZ, "Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes", ACI Structural Journal, 98(4), pp.451~461 (2001)
- Al-Salloum YA, "Influence of edge sharpness on the strength of square concrete columns confined with FRP composite laminates", Composites Part B: Engineering, 38, pp.640~650 (2007)[DOI]
- Wang LM, "Effect of corner radius on the performance of CFRP-confined square concrete columns: Test", Eng Struct, 30(2), pp.493~505 (2008)[DOI]
- Yan Z, "Concrete column shape modification with FRP shells and expansive cement concrete", Constr Build Mater, 25(1), pp.396~405 (2011)[DOI]
- Carbon fiber jacket retrofit test of circular shear bridge column. CRC-2, "Seible F", University of California, ~, pp.Advanced Composites Technology Transfer Consortium Rep. No. ACTT-94 (1994), 02
- Rectangular carbon jacket retrofit of flexural column with 5% continuous reinforcement, "Seible F", University of California, ~, pp.Advanced Composites Technology Transfer Consortium Report No. ACTT-95 (1995), 03
- Carbon fiber jacket retrofit test of circular flexural columns with lap spliced reinforcement, "Seible F", University of California, ~, pp.Advanced Composites Technology Transfer Consortium Report No. ACTT-95 (1995), 04
- Seible F, "Seismic retrofit of RC columns with continuous carbon fiber jackets", Journal of Composites for Construction, 1(2), pp.52~62 (1997)[DOI]
- Shake table test of a 1, "6 scale twostory lightly reinforced concrete building", El-Attar AG, 1991, NCEER-91-0017
- Di Ludovico M, "Seismic behavior of a full-scale RC structure retrofitted using GFRP laminates", J Struct Eng, 135(5), pp.810~821 (2008)
- Garcia R, "Seismic behavior of deficient RC frames strengthened with CFRP composites", Eng Struct, 32(10), pp.3075~3085 (2010)[DOI]
- Koutromanos I, "Shake-table tests of a 3-story masonry-infilled RC frame retrofitted with composite materials", J. Struct. Eng. 2013 SPECIAL ISSUE: NEES 2: Advances in Earthquake Engineering, 139, pp.1340~1351 (2013)
- Hudson DE, "A comparison of theoretical and experimental determination of building responses to earthquakes", Proc 2nd World conference on earthquake engineering, pp.1105~1119 (1960)
- Galambos T, "Lessons from dynamic tests of an eleven story building", Engng Struct, 1, pp.264~273 (1979)[DOI]
- Yu E, "Forced vibration testing of buildings using the linear shaker seismic simulation (LSSS) testing method", Earthquake Engng. Struct. Dyn., 34(1), pp.737~761 (2005)[DOI]
- Yu E, "Forced vibration testing of a four story RC building utilizing the nees@UCLA mobile field laboratory", Earthquake Spectra, 24, pp.969~995 (2008)[DOI]
- ACI, "Building code requirements for reinforced concrete. ACI 318-363", ~ (1963)
- Wright TR, "Full-scale seismic testing of a reinforced concrete moment frame using mobile shakers", PhD, pp.2015
- Shin J, "Multi-hazard performance criteria for non-ductile reinforced concrete frame buildings retrofitted with an FRP column jacketing system", PhD, pp.2017
- Ma R, "Full-scale testing of a parking structure column retrofitted with carbon fiber reinforced composites", J Construct Building Mater, 14(2), pp.63~71 (2000)[DOI]
- Techniques for the seismic rehabilitation of existing buildings, "FEMA", Federal Emergency Management Agency, ~, pp.Rep. No. FEMA 547 (2006)
- Pre-standard and commentary for the seismic rehabilitation of buildings, prepared by ASCE, "FEMA", Federal Emergency Management Agency, ~, pp.Rep. No. FEMA 356 (2000)
- ASCE, "Seismic Evaluation and Retrofit of Existing Buildings, ASCE", SEI 41-13, 2014
- Ji X, "Effect of gravity columns on mitigation of drift concentration for braced frames", J Constr Steel Res, 65, pp.2148~2156 (2009)[DOI]
- Qu Z, "Seismic damage mechanism control of RC ductile frames from a stiffness point of view", Proc 8th international conference on urban earthquake engineering (2011)