비부착 강연선과 고강도 콘크리트를 적용한 철근콘크리트 외부 접합부의 내진 거동
Seismic Behavior of RC Beam-Column Exterior Joints with Unbonded Tendons and High Strength Concrete
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
n the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.
Abstract
n the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.
참고문헌 (12)
- "Joint ACI-ASCE Committee 352. Recommendation for design of beam-column connections in monolithic reinforced concrete structures (ACI 352R-02)", American Concrete Institute, 38~ (2002)
- Ehsani MR, "Design recommendations for type 2high-strength reinforced concrete connections", ACI Structural Journal, 88(30), pp.277~291 (1991)
- 김윤일, "반복하중을 받는 초고강도 콘크리트 외측 보-기둥 접합부의 전단강도에 관한 실험 연구", 대한건축학회논문집 구조계, 24(3), pp.61~70 (2008), 대한건축학회
- 이범식, "고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가", 한국구조물진단유지관리공학회 논문집, 18(6), pp.72~81 (2014), 한국구조물진단유지관리공학회
- 황현종, "600 MPa 휨 철근을 사용한 특수모멘트 골조의 보-기둥 접합부의 내진성능", 콘크리트학회 논문집, 23(5), pp.591~601 (2011), 한국콘크리트학회
- Korea Concrete Institute, "Design code for concrete structures", Korea Concrete Institute, 599~ (2012)
- "ACI Committee 318. Building code requirements for structural concrete and commentary (ACI 318-11)", American Concrete Institute, 503~ (2011)
- Wallace JW, "Use of headed reinforcement in beam-column joints subjected to earthquake loads", ACI Structural Journal, 95(5), pp.590~602 (1998)
- Kang TH-K, "Bar pullout tests and seismic tests of small-headed bars in beam-column joints", ACI Structural Journal, 107(1), pp.32~42 (2010)
- Chun SC, "Mechanical anchorage in exterior beam-column joints subjected to cyclic loading", ACI Structural Journal, 104(1), pp.102~112 (2007)
- Kang TH-K, "Cyclic testing for seismic design guide of beam-column joints with closely spaced headed bars", Journal of Earthquake Engineering, 16(2), pp.211~230 (2012)
- "ACI Committee 374. Acceptance criteria for moment frames based on structural testing and commentary (ACI 374.1-05)", American Concrete Institute, 9~ (2005)
