본문 바로가기
KERD
논문KCI 등재

하이브리드 슈퍼코팅(HSC)과 유리섬유를 통한 조적조 내진보강 연구

Experimental Study of Hybrid Super Coating (HSC) and Cast Reinforcement for Masonry Wall

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류토목공학

초록

Many Korean domestic masonry structures constructed since 1970 have been found to be vulnerable to earthquakes because they lack efficient lateral force resistance. Many studies have shown that the brick and mortar suddenly experience brittle fracture and out-of-plane collapse when they reach the inelastic range. This study evaluated the seismic retrofitting of non-reinforced masonry with Hybrid Super Coating (HSC) and Cast, manufactured using glass fiber. Four types of specimen original specimen (BR-OR), one layered HSC (BR-HS-O), two-layered HSC (BR-HS-B), one layered HSC, and Cast (BR-CT-HS-O) were constructed and analyzed using compression, flexural tensile, diagonal compression, and triplet tests. The specimen responses were presented and discussed in load-displacement curves, maximum strength, and crack propagation. The compressive strength of the retrofit specimens slightly increased, while the flexural tensile strength of the retrofit specimens increased significantly. In addition, the HSC and Cast also produced a considerable increase in the ductile response of specimens before failure. Diagonal compression test results showed that HSC delayed brittle cracks between the mortar and bricks and resulted in larger displacement before failure than the original brick. The triplet test results confirmed that the bonding strength of the retrofit specimens also increased. The application of HSC and Cast was found to restrain the occurrence of brittle failure effectively and delayed the collapse of masonry wall structures.

Abstract

Many Korean domestic masonry structures constructed since 1970 have been found to be vulnerable to earthquakes because they lack efficient lateral force resistance. Many studies have shown that the brick and mortar suddenly experience brittle fracture and out-of-plane collapse when they reach the inelastic range. This study evaluated the seismic retrofitting of non-reinforced masonry with Hybrid Super Coating (HSC) and Cast, manufactured using glass fiber. Four types of specimen original specimen (BR-OR), one layered HSC (BR-HS-O), two-layered HSC (BR-HS-B), one layered HSC, and Cast (BR-CT-HS-O) were constructed and analyzed using compression, flexural tensile, diagonal compression, and triplet tests. The specimen responses were presented and discussed in load-displacement curves, maximum strength, and crack propagation. The compressive strength of the retrofit specimens slightly increased, while the flexural tensile strength of the retrofit specimens increased significantly. In addition, the HSC and Cast also produced a considerable increase in the ductile response of specimens before failure. Diagonal compression test results showed that HSC delayed brittle cracks between the mortar and bricks and resulted in larger displacement before failure than the original brick. The triplet test results confirmed that the bonding strength of the retrofit specimens also increased. The application of HSC and Cast was found to restrain the occurrence of brittle failure effectively and delayed the collapse of masonry wall structures.

참고문헌 (25)

  1. "Statistics KOREA Government Official Work Conference" (2007)[URL]
  2. Chang KK, "Present State and Necessity of Seismic Design for Low-rise Masonry Buildings in Korea", Journal of the Architectural Institute of Korea, 55(5), pp.45~50 (2011)
  3. Yu E, "Seismic Performance and Retrofit of Masonry-infilled Frames", Magazine of the Korea Concrete Institute, 27(6), pp.41~45 (2015)
  4. Pavan GS, "Behavior of brick–mortar interfaces in FRP-strengthened masonry assemblages under normal loading and shear loading", Journal of Materials in Civil Engineering, 28(2), pp.04015120~ (2016)
  5. Messali F, "Experimental results on the retrofitting of hollow brick masonry walls with reinforced high performance mortar coatings", Construction and Building Materials, 141, pp.619~630 (2017)
  6. Valluzzi MR, "Shear behavior of masonry panels strengthened by FRP laminates", Construction and Building Materials, 16(7), pp.409~416 (2002)
  7. Gams M, "Seismic strengthening of brick masonry by composite coatings: An experimental study", Bulletin of Earthquake Engineering, 15(10), pp.4269~4298 (2017)
  8. ElGawady MA, "Retrofitting of masonry walls using shotcrete", 2006 NZSEE Conference (2006)
  9. Tomazevic M, "Earthquake-resistant design of masonry buildings (Vol. 1)" (1999), World Scientific
  10. Vega C, "External strengthening of unreinforced masonry walls with polymers reinforced with carbon fiber", Ingeniería e Investigación, 38(3), pp.15~23 (2018)
  11. Kim HC, "Experimental Study on the Material Properties of Unreinforced Masonry Considering Earthquake Load", Journal of the Earq uake Engineering Society of Korea, 5(2), pp.93~101 (2001)
  12. 이정한, "중저층 건축물의 내진성능 및 내진보강 : 순수조적조, 조적채움벽 철근콘크리트 골조 및 강재 슬릿댐퍼 보강 철근콘크리트 골조", 박사, 건축공학, pp.2005
  13. 유은종, "조적채움벽의 전단강도에 따른 채움벽골조의 내진성능", 한국지진공학회논문집, 19(4), pp.173~181 (2015), 한국지진공학회
  14. 유혜란, "토벽돌과 석회모르타르를 사용한 조적구조의 역학적 특성에 관한 연구", 한국구조물진단유지관리공학회 논문집, 15(4), pp.87~98 (2011), 한국구조물진단유지관리공학회
  15. Korea Infrastructure Safety Corporation, "Guidelines for Evaluating Seismic Performance of Existing Building", 96~98 (2019)
  16. Korean Standards Association, "KS F 4004. Concrete bricks", Korea Standard Assoc, ~ (2013)
  17. Korean Standards Association, "KS L 510 5: Testing Method for Compressive Strength of Hydraulic Cement Mortars", Korean Standards Association, ~ (2017)
  18. Korean Standards Association, "KS L 5220. Dry ready mixed cement mortar", Korea Standard Association, ~ (2018)
  19. ASTM International, "ASTM C 1314-12 Standard Test Method for Compressive Strength of Masonry Prisms", ASTM International, ~ (2012)
  20. ASTM International, "ASTM E518", E518M-10 Standard Test Methods for Flexural Bond Strength of Masonry, 2010
  21. ASTM International, "ASTM E 519", E 519M-10 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages, 2010
  22. "BS EN 1052-3 Methods of test for masonry-Part 3: Determination of initial shear strength", ~ (2002)
  23. 이원호, "비보강 조적벽체 전단내력 평가에 관한 연구", 대한건축학회논문집 구조계, 21(10), pp.3~12 (2005), 대한건축학회
  24. 박병태, "비내진 상세를 가진 조적채움벽의 내진성능평가", 한국안전학회지, 32(1), pp.66~74 (2017), 한국안전학회
  25. 성한석, "고성능 복합재료로 보강된 조적채움벽 골조의 내진성능에 관한 연구", 콘크리트학회 논문집, 31(5), pp.449~458 (2019), 한국콘크리트학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (3건)