There have been meaningful changes in column stirrup spacing by KDS 41 20 00 in 2022, which is to decrease one of the spacing limits from the minimum section dimension to half of the minimum section dimension. Decreased column stirrup spacing increases the seismic shear resistance of columns and the seismic performance of the entire building. Among the effects of the column stirrup spacing change, this study focused on deformation compatibility in the seismic design of building frame system buildings with ordinary shear walls for seismic design category D. The beams and columns in building frame systems shall satisfy moment and shear strength, or deformation capability induced by seismic design displacement for satisfaction of the deformation compatibility. The commentary of KDS 41 17 00 describes that the deformation compatibility check can be ignored if the members in moment frames are upgraded to intermediate section details. The study showed that the deformation compatibility of columns was satisfied without additional consideration if the building frame systems were designed by the decreased column spacing in KDS 41 20 00. However, beams adjacent to walls needed further consideration, such as the recommendation of commentary in the code.

Abstract

There have been meaningful changes in column stirrup spacing by KDS 41 20 00 in 2022, which is to decrease one of the spacing limits from the minimum section dimension to half of the minimum section dimension. Decreased column stirrup spacing increases the seismic shear resistance of columns and the seismic performance of the entire building. Among the effects of the column stirrup spacing change, this study focused on deformation compatibility in the seismic design of building frame system buildings with ordinary shear walls for seismic design category D. The beams and columns in building frame systems shall satisfy moment and shear strength, or deformation capability induced by seismic design displacement for satisfaction of the deformation compatibility. The commentary of KDS 41 17 00 describes that the deformation compatibility check can be ignored if the members in moment frames are upgraded to intermediate section details. The study showed that the deformation compatibility of columns was satisfied without additional consideration if the building frame systems were designed by the decreased column spacing in KDS 41 20 00. However, beams adjacent to walls needed further consideration, such as the recommendation of commentary in the code.

관련 논문AI추천

이 간행물의 다른 논문 (3건)