Objectives. Malformations of the inner ear account for approximately 20% of cases of congenital deafness. In current practice, straight arrays with circumferential electrodes (i.e., full-banded electrodes) are widely used in severely malformed cochleae. However, the unpredictability of the location of residual spiral ganglion neurons in such malformations argues against obligatorily using full-banded electrodes in all cases. Here, we present our experience of electrically evoked compound action potential (ECAP) and radiography-based selection of an appropriate electrode for severely malformed cochleae. Methods. Three patients with severely malformed cochleae, showing cochlear hypoplasia type II (CH-II), incomplete partition type I (IP-I), and cochlear aplasia with a dilated vestibule (CADV), respectively, were included, and the cochlear nerve deficiency (CND) was evaluated. A full-banded electrode (CI24RE(ST)) and slim modiolar electrode (CI632) were alternately inserted to compare ECAP responses and electrode position. Results. In patient 1 (CH-II with CND), who had initially undergone cochlear implantation (CI) using a lateral wall electrode (CI422), revision CI was performed due to incomplete insertion of CI422 and resultant unsatisfactory performance by explanting the CI422 and re-inserting the CI24RE(ST) and CI632 sequentially. Although both electrodes elicited reliable ECAP responses with correct positioning, CI24RE(ST) showed overall lower ECAP thresholds compared to CI632; thus, CI24RE(ST) was selected. In patient 2 (IP-I with CND), CI632 elicited superior ECAP responses relative to CI24RE(ST), with correct positioning of the electrode; CI632 was chosen. In patient 3 (CADV), CI632 did not elicit an ECAP response, while meaningful ECAP responses were obtained with the CI24RE(ST) array once correct positioning was achieved. All patients’ auditory performance markedly improved postoperatively. Conclusion. The ECAP and radiography-based strategy to identify an appropriate electrode may be useful for severely malformed cochleae, leading to enhanced functional outcomes. The practice of sticking to full-banded straight electrodes may not always be optimal for IP-I and CH-II.

Abstract

Objectives. Malformations of the inner ear account for approximately 20% of cases of congenital deafness. In current practice, straight arrays with circumferential electrodes (i.e., full-banded electrodes) are widely used in severely malformed cochleae. However, the unpredictability of the location of residual spiral ganglion neurons in such malformations argues against obligatorily using full-banded electrodes in all cases. Here, we present our experience of electrically evoked compound action potential (ECAP) and radiography-based selection of an appropriate electrode for severely malformed cochleae. Methods. Three patients with severely malformed cochleae, showing cochlear hypoplasia type II (CH-II), incomplete partition type I (IP-I), and cochlear aplasia with a dilated vestibule (CADV), respectively, were included, and the cochlear nerve deficiency (CND) was evaluated. A full-banded electrode (CI24RE(ST)) and slim modiolar electrode (CI632) were alternately inserted to compare ECAP responses and electrode position. Results. In patient 1 (CH-II with CND), who had initially undergone cochlear implantation (CI) using a lateral wall electrode (CI422), revision CI was performed due to incomplete insertion of CI422 and resultant unsatisfactory performance by explanting the CI422 and re-inserting the CI24RE(ST) and CI632 sequentially. Although both electrodes elicited reliable ECAP responses with correct positioning, CI24RE(ST) showed overall lower ECAP thresholds compared to CI632; thus, CI24RE(ST) was selected. In patient 2 (IP-I with CND), CI632 elicited superior ECAP responses relative to CI24RE(ST), with correct positioning of the electrode; CI632 was chosen. In patient 3 (CADV), CI632 did not elicit an ECAP response, while meaningful ECAP responses were obtained with the CI24RE(ST) array once correct positioning was achieved. All patients’ auditory performance markedly improved postoperatively. Conclusion. The ECAP and radiography-based strategy to identify an appropriate electrode may be useful for severely malformed cochleae, leading to enhanced functional outcomes. The practice of sticking to full-banded straight electrodes may not always be optimal for IP-I and CH-II.

참고문헌 (20)

  1. Jensen J, "Malformations of the inner ear in deaf children: a tomographic and clinical study", Acta Radiol Diagn (Stockh), 286, pp.3~ (1968)
  2. Suk Y, "Surgical outcomes after cochlear implantation in children with incomplete partition type I: comparison with deaf children with a normal inner ear structure", Otol Neurotol, 36(1), pp.e11~e17 (2015)
  3. Eftekharian A, "Cochlear implantation in 8 incomplete partition type I", Eur Arch Otorhinolaryngol, 276(10), pp.2763~2768 (2019)
  4. Jeong SW, "Cochlear implantation in children with cochlear aplasia", Acta Otolaryngol, 132(9), pp.910~915 (2012)
  5. Schmidt JM, "Cochlear neuronal populations in developmental defects of the inner ear: implications for cochlear implantation", Acta Otolaryngol, 99(1-2), pp.14~20 (1985)
  6. Nadol JB Jr, "Patterns of neural degeneration in the human cochlea and auditory nerve: implications for cochlear implantation", Otolaryngol Head Neck Surg, 117(3 Pt 1), pp.220~228 (1997)
  7. Sennaroglu L, "Surgical results of cochlear implantation in malformed cochlea", Otol Neurotol, 27(5), pp.615~623 (2006)
  8. Berrettini S, "Cochlear implant in incomplete partition type I", Acta Otorhinolaryngol Ital, 33(1), pp.56~62 (2013)
  9. Graham JM, "Congenital malformations of the ear and cochlear implantation in children: review and temporal bone report of common cavity", J Laryngol Otol Suppl, 25, pp.1~14 (2000)
  10. Eisenman DJ, "Implantation of the malformed cochlea", Otol Neurotol, 22(6), pp.834~841 (2001)
  11. Lee SY, "Modiolar proximity of slim modiolar electrodes and cochlear duct length: correlation for potential basis of customized cochlear implantation with perimodiolar electrodes", Ear Hear, 42(2), pp.323~333 (2020)
  12. Briaire JJ, "Unraveling the electrically evoked compound action potential", Hear Res, 205(1-2), pp.143~156 (2005)
  13. Lee SY, "Simpler and effective radiological evaluations for modiolar proximity of a slim modiolar cochlear implant electrode", Sci Rep, 10(1), pp.17714~ (2020)
  14. Sennaroglu L, "A new classification for cochleovestibular malformations", Laryngoscope, 112(12), pp.2230~2241 (2002)
  15. Sennaroglu L, "Classification and current management of inner ear malformations", Balkan Med J, 34(5), pp.397~411 (2017)
  16. Archbold S, "Categories of auditory performance", Ann Otol Rhinol Laryngol Suppl, 166, pp.312~314 (1995)
  17. 윤미선, "한국어 영유아청각통합능력척도(IT-MAIS)의 타당도와 신뢰도 평가", Communication Sciences and Disorders, 16(4), pp.494~502 (2011), 한국언어청각임상학회
  18. Dhanasingh A, "An overview of cochlear implant electrode array designs", Hear Res, 356, pp.93~103 (2017)
  19. Sennaroglu L, "Histopathology of inner ear malformations: do we have enough evidence to explain pathophysiology?", Cochlear Implants Int, 17(1), pp.3~20 (2016)
  20. Kim SY, "Evaluating reasons for revision surgery and device failure rates in patients who underwent cochlear implantation surgery", JAMA Otolaryngol Head Neck Surg, 146(5), pp.414~420 (2020)

관련 논문AI추천

Cochlear Implants for Patients With Common Cavity Deformities and the Impact of Electrode Positioning배성훈, 최재영, 최지훈대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2022 · 제15권 제1호와우축을 감싸는 가는 전극을 가진 CI532 기기를 이용한 인공와우 수술의 단기 경험: 기존의 기기와의 비교강우석, 곽민영, 김예리, 박진택, 박홍주, 안중호, 이지연, 정종우대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2021 · 제64권 제4호Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types강시형, 김은연, 문일준, 백은주, 설혜윤, 이지영, 홍성화대한청각학회 · Journal of Audiology & Otology2019 · 제23권 제3호Precision Medicine Approach to Cochlear Implantation김예리, 최병윤대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2022 · 제15권 제4호Estimation of Angular Insertion Depth of a Cochlear Implant Electrode Array: Three-Dimensional Reconstruction Versus Spiral FormulaeAditi Shetty, Charalampos Komninos, Christos Bergeles, Gowri Pradeep, Irumee Pai, Sebastien Ourselin, Steve Connor대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2025 · 제18권 제4호외이도 폐쇄증과 와우 및 와우신경 기형을 동반한 소아 환자에게 시행한 인공와우이식 1예이창배, 정성욱, 홍승우대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2020 · 제63권 제10호

이 간행물의 다른 논문 (14건)