The Efficiency of Simultaneous Binaural Ocular Vestibular Evoked Myogenic Potentials: A Comparative Study with Monaural Acoustic Stimulation in Healthy Subjects

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Objectives. To evaluate the test-retest reliability and convenience of simultaneous binaural acoustic-evoked ocular vestibular evoked myogenic potentials (oVEMP). Methods. Thirteen healthy subjects with no history of ear diseases participated in this study. All subjects underwent oVEMP test with both separated monaural acoustic stimulation and simultaneous binaural acoustic stimulation. For evaluating test-retest reliability, three repetitive sessions were performed in each ear for calculating the intraclass correlation coefficient (ICC) for both monaural and binaural tests. We analyzed data from the biphasic n1-p1 complex, such as latency of peak, inter-peak amplitude, and asymmetric ratio of amplitude in both ears. Finally, we checked the total time required to complete each test for evaluating test convenience. Results. No significant difference was observed in amplitude and asymmetric ratio in comparison between monaural and binaural oVEMP. However, latency was slightly delayed in binaural oVEMP. In test-retest reliability analysis, binaural oVEMP showed excellent ICC values ranging from 0.68 to 0.98 in latency, asymmetric ratio, and inter-peak amplitude. Additionally, the test time was shorter in binaural than monaural oVEMP. Conclusion. oVEMP elicited from binaural acoustic stimulation yields similar satisfactory results as monaural stimulation. Further, excellent test-retest reliability and shorter test time were achieved in binaural than in monaural oVEMP.

Abstract

Objectives. To evaluate the test-retest reliability and convenience of simultaneous binaural acoustic-evoked ocular vestibular evoked myogenic potentials (oVEMP). Methods. Thirteen healthy subjects with no history of ear diseases participated in this study. All subjects underwent oVEMP test with both separated monaural acoustic stimulation and simultaneous binaural acoustic stimulation. For evaluating test-retest reliability, three repetitive sessions were performed in each ear for calculating the intraclass correlation coefficient (ICC) for both monaural and binaural tests. We analyzed data from the biphasic n1-p1 complex, such as latency of peak, inter-peak amplitude, and asymmetric ratio of amplitude in both ears. Finally, we checked the total time required to complete each test for evaluating test convenience. Results. No significant difference was observed in amplitude and asymmetric ratio in comparison between monaural and binaural oVEMP. However, latency was slightly delayed in binaural oVEMP. In test-retest reliability analysis, binaural oVEMP showed excellent ICC values ranging from 0.68 to 0.98 in latency, asymmetric ratio, and inter-peak amplitude. Additionally, the test time was shorter in binaural than monaural oVEMP. Conclusion. oVEMP elicited from binaural acoustic stimulation yields similar satisfactory results as monaural stimulation. Further, excellent test-retest reliability and shorter test time were achieved in binaural than in monaural oVEMP.

참고문헌 (20)

  1. Welgampola MS, "Characteristics and clinical applications of vestibular-evoked myogenic potentials", Neurology, 64(10), pp.1682~1688 (2005)
  2. Murofushi T, "Absent vestibular evoked myogenic potentials in vestibular neurolabyrinthitis: an indicator of inferior vestibular nerve involvement?", Arch Otolaryngol Head Neck Surg, 122(8), pp.845~848 (1996)
  3. Colebatch JG, "Myogenic potentials generated by a click-evoked vestibulocollic reflex", J Neurol Neurosurg Psychiatry, 57(2), pp.190~197 (1994)
  4. Todd NP, "Ocular vestibular evoked myogenic potentials (OVEMPs) produced by air- and bone-conducted sound", Clin Neurophysiol, 118(2), pp.381~390 (2007)
  5. Iwasaki S, "Head taps evoke a crossed vestibulo-ocular reflex", Neurology, 68(15), pp.1227~1229 (2007)
  6. Rosengren SM, "Vestibular-evoked extraocular potentials produced by stimulation with bone-conducted sound", Clin Neurophysiol, 116(8), pp.1938~1948 (2005)
  7. Manzari L, "Dissociation between cVEMP and oVEMP responses: different vestibular origins of each VEMP?", Eur Arch Otorhinolaryngol, 267(9), pp.1487~1489 (2010)
  8. Curthoys IS, "Bone conducted vibration selectively activates irregular primary otolithic vestibular neurons in the guinea pig", Exp Brain Res, 175(2), pp.256~267 (2006)
  9. Suzuki JI, "Eye movements from single utricular nerve stimulation in the cat", Acta Otolaryngol, 68(4), pp.350~362 (1969)
  10. Todd NP, "The origin of the ocular vestibular evoked myogenic potential (OVEMP)", Clin Neurophysiol, 121(6), pp.978~980 (2010)
  11. Wang SJ, "Ocular vestibular-evoked myogenic potentials elicited from monaural versus binaural acoustic stimulations", Clin Neurophysiol, 120(2), pp.420~423 (2009)
  12. Rosengren SM, "Vestibular evoked myogenic potentials: past, present and future", Clin Neurophysiol, 121(5), pp.636~651 (2010)
  13. Nguyen KD, "Test-retest reliability and age-related characteristics of the ocular and cervical vestibular evoked myogenic potential tests", Otol Neurotol, 31(5), pp.793~802 (2010)
  14. Maes L, "The vestibular evoked myogenic potential: a test-retest reliability study", Clin Neurophysiol, 120(3), pp.594~600 (2009)
  15. Isaradisaikul S, "Reliability of vestibular evoked myogenic potentials in healthy subjects", Otol Neurotol, 29(4), pp.542~544 (2008)
  16. Versino M, "Vestibular evoked myogenic potentials: test-retest reliability", Funct Neurol, 16(4), pp.299~309 (2001)
  17. Curthoys IS, "A critical review of the neurophysiological evidence underlying clinical vestibular testing using sound, vibration and galvanic stimuli", Clin Neurophysiol, 121(2), pp.132~144 (2010)
  18. Welgampola MS, "Evoked potential testing in neuro-otology", Curr Opin Neurol, 21(1), pp.29~35 (2008)
  19. Rosengren SM, "Ocular vestibular evoked myogenic potentials in superior canal dehiscence", J Neurol Neurosurg Psychiatry, 79(5), pp.559~568 (2008)
  20. Chihara Y, "Vestibular-evoked extraocular potentials by air-conducted sound: another clinical test for vestibular function", Clin Neurophysiol, 118(12), pp.2745~2751 (2007)

관련 논문AI추천

정상인에서 외안근 전정유발근전위의 특성: 경부 전정유발근전위와의 비교 연구고일주, 김형종, 이효정, 장은석, 홍성광대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2009 · 제52권 제12호Test-Retest Reliability of Tone Burst-Induced 500 Hz Air-Conduction Masseter Vestibular Evoked Myogenic Potential in Healthy IndividualsAlagendraraja Ramsankar Sujjuri, Ramesh Keerthi, Thirunavukkarasu Kumaran대한청각학회 · Journal of Audiology & Otology2024 · 제28권 제4호Capacity of Rectified Vestibular Evoked Myogenic Potential in Correcting Asymmetric Muscle Contraction Power김건우, 서명환, 이정현, 정재윤대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2013 · 제6권 제4호경부 전정유발근전위와 외안근 전정유발근전위의 동시측정박영애, 신현준, 오선영대한신경과학회 · 대한신경과학회지2015 · 제33권 제3호Can Narrow Band Chirp Stimulus Shake the Throne of 500 Hz Tone Burst Stimulus for Cervical Vestibular Myogenic Potentials?Coban Volkan Kenan, Karacayli Ceren, Ocal F Ceyda Akin, Satar Bulent대한청각학회 · Journal of Audiology & Otology2021 · 제25권 제2호Difference of Diagnostic Rates and Analytical Methods in the Test Positions of Vestibular Evoked Myogenic Potentials김희, 김지현, 박상유, 박정미, 용상열, Jong Heon Kim대한재활의학회 · Annals of Rehabilitation Medicine2014 · 제38권 제2호