강제환기식 양돈시설의 암모니아 및 미세먼지 배출계수 산정
Estimation of Particulate Matter and Ammonia Emission Factors for Mechanically-Ventilated Pig Houses
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Emission factors for ammonia and particulate matters (PMs) from livestock buildings are of increasing importance in view of the environmentalprotection. While the existing emission factors were determined based on the emission inventory of other countries, in situ measurement of emissionfactors is required to construct an accurate emission inventory for Korea. This study is to report measurements of ammonia and PMs emissions frommechanically-ventilated pig houses, which are common types of pig barns in Korea. Ventilation rates and concentrations of ammonia and PMs weremeasured at the ventilation outlets of a weaner unit, a growing pig unit and a fattening pig unit to calculated the emission factors. The PMs emissionwas characterized with different aerodynamic diameters (PM2.5, PM10, and total suspended particulates (TSP)). The measured ammonia emission factorsfor weaners, growing pigs and fattening pigs were 0.225, 0.869 and 1.679 kg animal-1 yr-1, respectively, showing linear increase with pigs’ age. ThePMs emission factors for three growing stages were 0.023, 0.237 and 0.241 kg animal-1 yr-1, respectively for TSP, 0.017, 0.072 and 0.223 kg animal-1yr-1, respectively for PM10, and 0.011, 0.016 and 0.151 kg animal-1 yr-1, respectively for PM2.5. PMs emissions were increased with pigs’ age due toincreasing feed supply and animal movement. The measured emission factors were smaller than those of the existing emission inventory indicating thatthe existing ones overestimate the emissions from pig buildings and also suggesting that long-term in situ monitoring at various livestock buildings isrequired to construct the accurate emission inventory.
Abstract
Emission factors for ammonia and particulate matters (PMs) from livestock buildings are of increasing importance in view of the environmentalprotection. While the existing emission factors were determined based on the emission inventory of other countries, in situ measurement of emissionfactors is required to construct an accurate emission inventory for Korea. This study is to report measurements of ammonia and PMs emissions frommechanically-ventilated pig houses, which are common types of pig barns in Korea. Ventilation rates and concentrations of ammonia and PMs weremeasured at the ventilation outlets of a weaner unit, a growing pig unit and a fattening pig unit to calculated the emission factors. The PMs emissionwas characterized with different aerodynamic diameters (PM2.5, PM10, and total suspended particulates (TSP)). The measured ammonia emission factorsfor weaners, growing pigs and fattening pigs were 0.225, 0.869 and 1.679 kg animal-1 yr-1, respectively, showing linear increase with pigs’ age. ThePMs emission factors for three growing stages were 0.023, 0.237 and 0.241 kg animal-1 yr-1, respectively for TSP, 0.017, 0.072 and 0.223 kg animal-1yr-1, respectively for PM10, and 0.011, 0.016 and 0.151 kg animal-1 yr-1, respectively for PM2.5. PMs emissions were increased with pigs’ age due toincreasing feed supply and animal movement. The measured emission factors were smaller than those of the existing emission inventory indicating thatthe existing ones overestimate the emissions from pig buildings and also suggesting that long-term in situ monitoring at various livestock buildings isrequired to construct the accurate emission inventory.
참고문헌 (15)
- Aarnink, A. J. A., "Ammonia emission patterns during the growing periods of pigs housed on partially slated floors", Journal of Agricultural Engineering Research, 65, pp.105~116 (1995)[DOI]
- Cambra-López, M., "Airborne particulate matter from livestock production systems : A review of an air pollution problem", Environmental Pollution, 158(1), pp.1~17 (2010)[DOI]
- Demmers, T. G. M., "Ammonia emission from two mechanically ventilated UK livestock buildings", Atmospheric Environment, 33, pp.217~227 (1999)[DOI]
- "EEA EMEP", CORINAIR emission inventory guidebook, 2016
- Groot Koerkamp, P. W. G., "Concentrations and emissions of ammonia in livestock buildings in Northern Europe", Journal of Agricultural Engineering Research, 70, pp.79~95 (1998)[DOI]
- Heber, A. J., "Size distribution and identification of aerial dust particles in swine finishing buildings", Transactions of the ASABE, 31(3), pp.0882~0887 (1988)[DOI]
- Hinz, T., "A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings Part 2 : Result", Journal of Agricultural Engineering Research, 70, pp.119~129 (1998)[DOI]
- 전의찬, "부유형 챔버를 이용한 하수처리장에서의 암모니아 배출 특성 연구", 환경영향평가, 14(5), pp.263~273 (2005), 한국환경영향평가학회
- 김민석, "국내외 가축분뇨 퇴액비 이용 분야 암모니아 배출량 인벤토리 비교 연구", 환경생물, 38(1), pp.71~81 (2020), 한국환경생물학회[DOI]
- 임광희, "축사 주변의 악취 및 부유분진의 CALPUFF 모델링: 계사 중심으로", Korean Chemical Engineering Research(HWAHAK KONGHAK), 57(1), pp.90~104 (2019), 한국화학공학회[DOI]
- Philippe, F. X., "Comparison of ammonia and greenhouse gas emissions during the fattening of pigs, kept either on fully slatted floor or on deep litter", Livestock Science, 111, pp.144~152 (2007)[DOI]
- 사재환, "축산분뇨에서 발생하는 암모니아 플럭스에 대한 환경인자의 영향에 관한 연구", 한국대기환경학회지, 26(4), pp.432~442 (2010), 한국대기환경학회
- Shin, D. W., "Management strategies to reduce pm-2.5 emission:Emphasis-ammonia" (2017), Korean Environment Institute
- Winkel, A., "Emissions of particulate matter from animal houses in the Netherlands", Atmospheric Environment, 111, pp.202~212 (2015)[DOI]
