본문 바로가기
KERD
논문

강제환기식 산란계 사육시설의 PM, NH3 발생⋅배출 특성 조사

Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류농학

초록

In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house wereevaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit consideringseasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10,PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgentto develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summerseason were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing nosignificant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

Abstract

In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house wereevaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit consideringseasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10,PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgentto develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summerseason were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing nosignificant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

참고문헌 (17)

  1. María Cambra-López, "Airborne particulate matter from livestock production systems: A review of an air pollution problem", Environmental Pollution, 158(1), pp.1~17 (2010), Elsevier BV[DOI]
  2. Kelley J. Donham, "Respiratory dysfunction in swine production facility workers: Dose-response relationships of environmental exposures and pulmonary function", American Journal of Industrial Medicine, 27(3), pp.405~418 (1995), Wiley[DOI]
  3. Donham, K. J., "Setting maximum dust exposure levels for people and animals in livestock facilities", Dust Control in Animal Production Facilities, pp.93~110 (1999), Scandinavian Congress Center
  4. H. H. Ellen, "Dust Levels and Control Methods in Poultry Houses", Journal of Agricultural Safety and Health, 6(4), pp.275~282 (2000), American Society of Agricultural and Biological Engineers (ASABE)[DOI]
  5. EMEP, "Atmospheric emission inventory guidebook", ~ (1999)
  6. "VERA test protocol forlivestock housing and management systems: Version 3:2018-09" (2018)[URL]
  7. 장동화, "강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석", 한국농공학회논문집, 63(1), pp.75~87 (2021), 한국농공학회[DOI]
  8. 조예슬, "윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구", 한국농공학회논문집, 57(6), pp.35~46 (2015), 한국농공학회[DOI]
  9. 김형아, "돈사 분진 함유 내독소 수준과 축사 작업자들의 세포면역력간 상관성 분석", 한국산업보건학회지, 23(4), pp.393~401 (2013), 한국산업보건학회
  10. 권경석, "강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석", 한국농공학회논문집, 56(6), pp.31~43 (2014), 한국농공학회
  11. Kyeong-seok Kwon, "Identification of key factors for dust generation in a nursery pig house and evaluation of dust reduction efficiency using a CFD technique", Biosystems Engineering, 151, pp.28~52 (2016), Elsevier BV[DOI]
  12. B.W. Mitchell, "Reducing Airborne Pathogens, Dust and Salmonella Transmission in Experimental Hatching Cabinets Using an Electrostatic Space Charge System", Poultry Science, 81(1), pp.49~55 (2002), Elsevier BV[DOI]
  13. National Institute of Environmental Research, "National air pollutants emission 2006", ~ (2019)
  14. R. Qi, "Dust Net Generation Rate in a Poultry Layer House", Transactions of the ASAE, 35(5), pp.1639~1645 (1992), American Society of Agricultural and Biological Engineers (ASABE)[DOI]
  15. K Radon, "Exposure assessment and lung function in pig and poultry farmers", Occupational and Environmental Medicine, 58(6), pp.405~410 (2001), BMJ[DOI]
  16. H. Takai, "Concentrations and Emissions of Airborne Dust in Livestock Buildings in Northern Europe", Journal of Agricultural Engineering Research, 70(1), pp.59~77 (1998), Elsevier BV[DOI]
  17. US EPA, "Measuring air quality : The pollutant standards index", United States Environmental Protection Agency, ~ (1994)