The Effect of Endoscopic Tympanoplasty on Cochlear Function
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives. The aim of this prospective clinical study was to measure the audiologic outcomes of the patients that underwent endoscopic transcanal cartilage tympanoplasty, and to investigate the effects on cochlear function. Methods. Thirty-three patients (33 ears) who were diagnosed with noncomplicated chronic otitis media and underwent endoscopic transcanal cartilage tympanoplasty technique were included. Pre- and postoperative first month distortion product otoacoustic emission (DPOAE) signal-to-noise ratio (SNR), bone conduction hearing levels and air bone gap (ABG) values were measured and total endoscope usage time was noted. Results. Preoperative median SNR measurements at 0.5, 1, 2, and 4 kHz were 6 dB (1–11; interquartile range [IQR], 1), 6 dB (4–20; IQR, 1), 7 dB (3–26; IQR, 5) and 5.50 dB (0–9; IQR, 3), respectively. Postoperative median SNR measurements at 0.5, 1, 2, and 4 kHz were 6 dB (3–9; IQR, 1), 6 dB (2–21; IQR, 3), 7 dB (2–20; IQR, 3), and 6 dB (0–10; IQR, 7), respectively. Regarding the DPOAE measurements, there was no statistically significant difference between the SNR values of all given frequencies (P>0.05). Regarding the pure tone audiometry (PTA) measurements, bone conduction was significantly better at 0.5 and 1 kHz, postoperatively (P<0.05) and there was statistically significant difference at 2 and 4 kHz (P>0.05). Additionally, no statistically significant correlation was found between the SNR and PTA measurements and the endoscope usage time (P>0.05). Conclusion. We suggested that cochlear functions and sensorineural hearing remained stable after endoscopic transcanal cartilage tympanoplasty and cold light source doesn’t cause significant adverse effects cochlear functions.
Abstract
Objectives. The aim of this prospective clinical study was to measure the audiologic outcomes of the patients that underwent endoscopic transcanal cartilage tympanoplasty, and to investigate the effects on cochlear function. Methods. Thirty-three patients (33 ears) who were diagnosed with noncomplicated chronic otitis media and underwent endoscopic transcanal cartilage tympanoplasty technique were included. Pre- and postoperative first month distortion product otoacoustic emission (DPOAE) signal-to-noise ratio (SNR), bone conduction hearing levels and air bone gap (ABG) values were measured and total endoscope usage time was noted. Results. Preoperative median SNR measurements at 0.5, 1, 2, and 4 kHz were 6 dB (1–11; interquartile range [IQR], 1), 6 dB (4–20; IQR, 1), 7 dB (3–26; IQR, 5) and 5.50 dB (0–9; IQR, 3), respectively. Postoperative median SNR measurements at 0.5, 1, 2, and 4 kHz were 6 dB (3–9; IQR, 1), 6 dB (2–21; IQR, 3), 7 dB (2–20; IQR, 3), and 6 dB (0–10; IQR, 7), respectively. Regarding the DPOAE measurements, there was no statistically significant difference between the SNR values of all given frequencies (P>0.05). Regarding the pure tone audiometry (PTA) measurements, bone conduction was significantly better at 0.5 and 1 kHz, postoperatively (P<0.05) and there was statistically significant difference at 2 and 4 kHz (P>0.05). Additionally, no statistically significant correlation was found between the SNR and PTA measurements and the endoscope usage time (P>0.05). Conclusion. We suggested that cochlear functions and sensorineural hearing remained stable after endoscopic transcanal cartilage tympanoplasty and cold light source doesn’t cause significant adverse effects cochlear functions.
참고문헌 (10)
- Ayache S, "Cartilaginous myringoplasty: the endoscopic transcanal procedure", Eur Arch Otorhinolaryngol, 270(3), pp.853~860 (2013)[DOI]
- Dundar R, "Temperature rises in the round window caused by various light sources during insertion of rigid endoscopes: an experimental animal study", Clin Otolaryngol, 41(1), pp.44~50 (2016)[DOI]
- MacKeith SA, "Thermal properties of operative endoscopes used in otorhinolaryngology", J Laryngol Otol, 122(7), pp.711~714 (2008)
- Bottrill I, "In vitro and in vivo determination of the thermal effect of middle ear endoscopy", Laryngoscope, 106(2), pp.213~216 (1996)[DOI]
- Lonsbury-Martin BL, "Cummings otolaryngology: head and neck surgery", pp.2345~2358 (2014), Saunders Elsevier
- Lonsbury-Martin BL, "The clinical utility of distortion-product otoacoustic emissions", Ear Hear, 11(2), pp.144~154 (1990)
- Aksoy F, "Thermal effects of cold light sources used in otologic surgery", Eur Arch Otorhinolaryngol, 272(10), pp.2679~2687 (2015)[DOI]
- Badr-El-Dine M, "Instrumentation and technologies in endoscopic ear surgery", Otolaryngol Clin North Am, 46(2), pp.211~225 (2013)[DOI]
- Kozin ED, "Thermal effects of endoscopy in a human temporal bone model: implications for endoscopic ear surgery", Laryngoscope, 124(8), pp.E332~E339 (2014)[DOI]
- Khan MM, "Endoscopic cartilage tympanoplasty: a two-handed technique using an endoscope holder", Laryngoscope, 126(8), pp.1893~1898 (2016)[DOI]
