본문 바로가기
KERD
논문

적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis

1

조회

0

다운로드

6

인용

0

참고문헌

주제분류농학

초록

Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were

Abstract

performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

참고문헌 (13)

  1. Bartok, J. W., "Energy conservation for commercial greenhouses. Natural Resouces, Agriculture, and Engineering Service 3", ~ (2007)
  2. Choe, G. S., "Development of in-site evaluation method for building insulation performance using infrared camera", In Proc. of the Korean Society of Air-conditioning and Refrigerating Engineers, pp.107~107 (2004)
  3. Choi, B. H., "Insulation performance evaluation of apartment housing using infra-red camera", In Proc. of the Korean Society of Air-conditioning and Refrigerating Engineers, pp.718~723 (2009)
  4. 최만용, "위상잠금 광-적외선 열화상 기술을 이용한 내부결함의 위치 및 크기 평가", 비파괴검사학회지, 27(4), pp.321~327 (2007), 한국비파괴검사학회
  5. 한정섭, "열화상 기술에 의한 M.C 나일론의 내부 결함에 대한 평가", 한국해양공학회지, 23(2), pp.81~86 (2009), 한국해양공학회
  6. Kim, J. Y., "Analysis on nondestructive temperature distribution of tire tread part in a running using infrared thermal vision camera", Proc. of the Korean Society for Nondestructive Testing, pp.198~203 (2001)
  7. Kim, M. K., "Bio-environment control engineering" (2002), Cheongsol Press
  8. Moon, J. P., "Heat loss audit and analysis on agricultural facilities (Greenhouse)", In Proc. of the Korean Sooiety for Bio-Environment Control, 18(1), pp.278~281 (2009)
  9. Case Collection of Heat Loss Audit for Agricultural Facilities, "Rural Development Administration", ~ (2009)
  10. Protected Cultivation Energy Saving Guidebook for Overcoming High Oil Price, "Rural Development Administration", ~ (2008)
  11. 심준기, "토목 구조물의 손상 검출을 위한 적외선 열화상 기법의 적용 사례 분석", 한국구조물진단유지관리공학회 논문집, 12(3), pp.71~83 (2008), 한국구조물진단유지관리공학회
  12. Greenhouse Gas Emissions Energy Principles of Diagnosis, "Son, H. S.", Korean Energy Information Center, ~ (2008)
  13. 문종필, "적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가", 한국농공학회논문집, 52(2), pp.67~73 (2010), 한국농공학회

관련 논문AI추천