초록

This study was carried out to provide a valuable reference which could reduce heating loss of air-inflated double PO film. Therefore,this study was aimed to choose the best air space thickness and injected air temperature. The characteristics of heat transmissionvariation at experimental materials were measured and analysed in the laboratory. The experiment was conducted of two layers of POfilm, each 0.15 mm tick, sandwiching 110, 175, 225 mm of inflated air with 1 m sides. Environmental control lab was constantlycontrolled with -10 ℃ and experiment chamber was constantly changed with 0, 5, 10, 15 ℃. The analysis of heat transfer showedthat heat transmission does not have a direct correlation with Air Space thickness and injected air temperature. But when inside andoutside temperature difference of chamber was great, supply of outside air to Air Space had an advantage at reduction of heatingload. It was required to examine accurate analysis at a real greenhouse.

Abstract

This study was carried out to provide a valuable reference which could reduce heating loss of air-inflated double PO film. Therefore,this study was aimed to choose the best air space thickness and injected air temperature. The characteristics of heat transmissionvariation at experimental materials were measured and analysed in the laboratory. The experiment was conducted of two layers of POfilm, each 0.15 mm tick, sandwiching 110, 175, 225 mm of inflated air with 1 m sides. Environmental control lab was constantlycontrolled with -10 ℃ and experiment chamber was constantly changed with 0, 5, 10, 15 ℃. The analysis of heat transfer showedthat heat transmission does not have a direct correlation with Air Space thickness and injected air temperature. But when inside andoutside temperature difference of chamber was great, supply of outside air to Air Space had an advantage at reduction of heatingload. It was required to examine accurate analysis at a real greenhouse.

참고문헌 (10)

  1. Boodley, J. W., "The commercial greenhouse" (1996), Delmar Publishers
  2. Fang, W., "Story of air-inflated double-layer polyethylene greenhouse and its recent applications in Taiwan", ASAE International Seminar on Agricultural Structures and Agricultural Engineering (2007), National Taiwan University
  3. Design standards for greenhouse environment (Ⅰ), "KRC", Korea Rural Community Corporation, ~ (1996)
  4. 이현우, "공기주입 이중피복 플라스틱온실의 공기주입장치 설계를 위한 기초실험", 한국농공학회논문집, 51(5), pp.19~24 (2009), 한국농공학회
  5. 이현우, "한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발", 시설원예‧식물공장, 18(3), pp.185~191 (2009), 한국생물환경조절학회
  6. 이현우, "토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성", 한국농공학회논문집, 52(5), pp.11~17 (2010), 한국농공학회
  7. Lee, K. M., "Environmental control and management automation" (1999), Ilil Publishers
  8. 이시영, "다겹보온자재의 보온성 비교 및 커튼개폐장치 개발", 시설원예‧식물공장, 16(2), pp.89~95 (2007), 한국생물환경조절학회
  9. 문종필, "적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가", 한국농공학회논문집, 52(2), pp.67~73 (2010), 한국농공학회
  10. Case collection of heat loss audit for agricultural facilities, "RDA", Rural Development Administration, ~ (2009)